-18-
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord. Allow the projector to
cool for at least 45 minutes.
2
Loosen 2 screws with a screwdriver and open the lamp cover.
3
Loosen 2 screws and pull out the lamp assembly by grasping the handle.
4
Replace the lamp assembly securely and tighten 2 screws.
5
Close the lamp cover and tighten 2 screws.
6
Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the interlock switch is also released to
switch off the mains power for safety.
7
Reset the Lamp Replace Counter, see below explanation
.
■
Lamp Replacement
1
Turn the projector on, and press the
MENU
button
and the on-screen menu will appear. Press the
POINT
LEFT/RIGHT
buttons to move a red frame pointer to
SETTING menu icon.
2
Press the
POINT DOWN
button to move a red frame
pointer to “Lamp counter reset” and then press the
SELECT
button. The message “Lamp replace counter
reset?” is displayed. Move the pointer to [Yes] and the
press the
SELECT
button.
3
Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
The LAMP REPLACEMENT indicator will illuminate
when the Lamp Replace Counter reaches 1000
hours. This is to indicate that lamp replacement is
required.
You can check the lamp replace counter following to
below procedure.
1
Press and hold the pointer
UP
on the projector for
more than 20 seconds.
2
The Lamp replace Counter is displayed on top left
corner of the screen briefly.
Lamp cover
Normal
123 h
Eco
105 h
Total
228 h
Lamp replace counter data
ORDER REPLACEMENT LAMP
Type No.
Service Parts No.
POA-LMP47
610 297 3891
How to reset Lamp Replace Counter
How to check Lamp Replace Counter
Screws
Handle
Lamp Assembly
Содержание PLC-XP41
Страница 47: ... 47 R TP21R G TP21G B TP21B R S H OUT TP561 TP1561 G S H OUT TP531 TP1531 B S H OUT TP501 TP1501 Waveforms ...
Страница 49: ... 49 IC Block Diagrams AD8183ARU AD8185ARU Selector IC101 IC201 IC5203 BA7078AF Sync Detector IC7141 ...
Страница 50: ... 50 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams BH3540 Volume Control IC1652 ...
Страница 51: ... 51 IC Block Diagrams FA5332M P F Controller IC601 FA7612CA PWC Controller IC6602 IC6603 IC6616 ...
Страница 53: ... 53 IC Block Diagrams L3E07050 Color Gamma Correction Timing Controller IC401 LB1641 Motor Drive IC1602 IC1611 ...
Страница 54: ... 54 LB1645 Motor Drive IC1601 LC863316 SUB CPU IC1851 IC Block Diagrams ...
Страница 55: ... 55 ML60851 USB I F IC9801 M62393 D A IC212 IC2381 IC Block Diagrams ...
Страница 56: ... 56 M62399 D A IC3501 IC3551 IC Block Diagrams PW365 System Control Scan Converter IC301 ...
Страница 57: ... 57 STR Z2156 Power Switching IC651 IC Block Diagrams SII161ACT DVI I F IC8001 ...
Страница 58: ... 58 TA1287 RGB YUV Converter IC4551 TB1274AF Video Decoder IC1101 IC Block Diagrams ...
Страница 59: ... 59 IC Block Diagrams TDA7056 Audio Output IC1631 IC1632 ...
Страница 89: ...MA8 XP4600 MA8 XP46L00 MB8 XP4100 MB8 XP41L00 89 Mechanical Parts List 51 a 51 43 43 51 b 23 a 23 b 23 ...
Страница 93: ...MA8 XP4600 MA8 XP46L00 MB8 XP4100 MB8 XP41L00 93 ...
Страница 94: ... MA8AA Apr 2002 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 95: ...Diagrams Drawings PLC XP46 PLC XP46L PLC XP41 PLC XP41L ...