-51-
Cleaning
Cleaning with air spray
1. Remove the cabinet top following to “Mechanical
Disassemblies”.
. Clean up the LCD panel and polarizing plate by
using the air spray from the cabinet top opening.
Caution:
Use a commercial (inert gas) air spray designed for
cleaning camera and computer equipment. Use a
resin-based nozzle only. Be vary careful not to damage
optical parts with the nozzle tip. Never use any kind of
cleanser on the unit. Also, never use abrasive materials
on the unit as this may cause irreparable damage.
After long periods of use, dust and other particles will accumulate on the LCD panel, prism, mirror, polarized
glass, lens, etc., causing the picture to darken or color to blur. If this occurs, clean the inside of optical unit.
Remove dust and other particles using air spray. If dirt cannot be removed by air spray, disassemble and clean
the optical unit.
disassembly Cleaning
Disassembly cleaning method should only be per-
formed when the unit is considerable dirty and cannot
be sufficiently cleaned by air spraying alone.
Be sure to readjust the optical system after per-
forming disassembly cleaning.
1. Remove the cabinet top and main units following to
“Mechanical Disassemblies”.
. Remove the optical base top following to “Optical
Unit Disassemblies”. If the LCD panel needs
cleaning, remove the LCD panel unit following to
“LCD panel replacement”.
3. Clean the optical parts with a soft cloth. Clean
extremely dirty areas using a cloth moistened with
alcohol.
Caution:
The surface of the optical components consists of mul-
tiple dielectric layers with varying degrees of refraction.
Never use organic solvents (thinner, etc.) or any kind
of cleanser on these components.
Since the LCD panel is equipped with an electronic
circuit, never use any liquids (water, etc.) to clean the
unit. Use of liquid may cause the unit to malfunction.
1
Disconnect the AC power cord before cleaning.
2
First, remove the dust with a blower.
Then gently wipe the lens surface. Use a lens clean-
ing paper moistened with methyl alcohol (methanol).
Avoid excessive use of cleaner.
Do not use abrasive cleaners, solvents, or other
harsh chemical cleaners not to damage the lens.
3
When the projector is not in use, replace the lens cover.
!
CAUtIoN
This projector is equipped with a plastic lens.
Do not rub with hard fiber cloth or do not hit the lens with something hard to prevent the lens from scratching.
Do not use chemical cleaner (liquid and solid) avoid deteriorating the lens.
Projection Lens Cleaning
Содержание PLC-XL40
Страница 53: ... 53 BA7078 Sync Separator IC5301 IC Block Diagrams BA9743 DDC Control IC5651 ...
Страница 54: ... 54 IC Block Diagrams L3E6100D D A S H LCD Driver IC501 IC531 IC561 FA5502 P F Control IC621 ...
Страница 55: ... 55 IC Block Diagrams L3E07072 LCD Driver Gamma Correction IC401 M62399 D A IC3531 ...
Страница 56: ... 56 IC Block Diagrams STR Z2156A Power Switching IC631 NJW1141 Audio Control IC5001 ...
Страница 57: ... 57 uPD64012 Video Decoder IC101 IC Block Diagrams ...
Страница 79: ...KY6 XL4000 79 Mechanical Parts List L11 L08 L12 L16 L04 L17 L10 L06 L03 L05 In the Optical Unit L08 ...
Страница 81: ...KY6 XL4000 81 Mechanical Parts List ...
Страница 82: ... KY6A Oct 2006 DC 350 Printed in Japan SANYO Electric Co Ltd ...