NOTE : Temperature monitor operation
The temperature monitor system is provided to prevents damage of
optical components (the LCD panel and polarization film etc.) inside
a projector from overheat. Two protection systems are provided. Each
system operation as follows :
------ The temperature monitor -1: -----------------------------------
■
To control the air-flow of the cooling fans.
The CPU checks the temperature and atmospheric pressure inside a
projector. It checks a temperature using temperature sensor-IC2541
and it checks an atmospheric pressure using pressure sensor-IC886.
The CPU judges data from sensors and controls the air flow of the
cooling fans so the temperature inside the projector is maintained to
normal temperature.
■
To shut down the projector urgent.
The CPU checks temperature of LCD panel periphery(Z8P & TH) and
inhalation air(IC5801). If each part temperature reaches to abnor-
mal temperature, the CPU will turn off the projector, and will blink
WARNING TEMP. indicator at intervals of 0.5 seconds. Cooling fans oper-
ate until temperature returns to normal. Indicator will stop blink, if tem-
perature returns to normal.
------ The temperature monitor -2 : ----------------------------------
■
Temperature check of lamps :
Temperature switches are arranged near the lamps. Temperature
switches will operate, if temperature reaches 12 0 degrees. When
temperature switches become open, they cut off 12V_PFC line, the
power failure "PF_TH" signal become Low, and then the CPU will shut
down the projector, and b
oth of READY and WARNING TEMP.
indicators will start flashing.
NOTE : SENSORS OPERATION
■
The sensor's operation is as follows:
IC886
: For FAN control
PTH901 : Abnormal temperature detection
IC2541
: Inside air temperature monitor
IC5801
: Abnormal temperature detection and
for FAN control
WARNING TEMP. indicator
(red) blink?
The projec tor is turned
off when the temperature
around the LCD panel reach-
es abnormal temperature.
And a WARNING TEMP. indi-
cator blinks.
The temperature
switch is operated?
If the temperature
around FET reaches 85
degrees, a PFC circuit
will be shut down.
The temperature switch is
operated?
When the temperature
around a lamp driver reach-
es 85 degrees, the lamp bal-
last will be shut down and
a lamp error signal changes
from L to H.
Temperature sensors location can be seen on
"protections"( page-8).
Troubleshooting
●
Temperature Abnormality
IC801
CPU
R/C
FAN
FAN
ASS'Y
POWER
UNIT_SUB POWER
NOISE
FILTER
AC
SENSOR
AC
INPUT
BALLAST
1/2/3/4
P.F.C.
1/2/3/4
LAMP_1/2/3/4
Z8P & TH
TEMP. SENSOR
IC2541
TEMP. SENSOR
IC5801
TEMP. SENSOR
IC886
PRESSURE SENSOR
INDICATORS
FAN
CONTROL
FAN
CONTROL
RESET KEY
SW902
LAMP COVER SW
DA
CONVERTER
SW903/904/905/906
THERMAL SW
MAINS
SW
FUSE
SWITCHING
POWER
SUPPLY
PRIMARY CIRCUIT
PF_
FANS
POWER
FAIL
POWER
FAIL
12VA
12V
PF_TH
LAMP1/2/3/4
PF_PFC1/2/3/4
PWR_SW
BLAST_SW1/2/3/4
IIC
IC5851
IO
IC1881
Check FAN
circuits.
Check the
temperature
switches.
Содержание PLC-XF47
Страница 149: ... 149 Mecanical and Optical Parts 26 S3 31 S1 S1 S1 S2 S2 S2 6 7 8 8 2 2 12 16 22 30 1 19 20 21 24 25 26 28 27 29 27 ...
Страница 151: ... 151 Mecanical and Optical Parts 66 87 87 87 87 89 89 88 88 88 88 73 74 75 76 85 59 60 61 63 64 66 65 ...
Страница 153: ... 153 Mecanical and Optical Parts 53 72 68 52 118 120 126 55 54 69 69 70 70 101 123 ...
Страница 154: ... 154 Mecanical and Optical Parts 102 103 115 114 114 121 121 125 112 119 118 122 117 ...
Страница 155: ... 155 Mecanical and Optical Parts 71 116 71 116 116 116 111 80 111 110 110 78 81 79 ...
Страница 195: ... 195 ...
Страница 196: ...SM5110880 PLC XF47 SEP 2007 BB 350 Printed in Japan ...
Страница 218: ......