13
-4
Relay lens unit removal.
1. Remove 2 screws-A and remove the Relay lens unit.
2. Remove 4 screws-B, remove the plate and remove the Relay lens.
(See Fig.13-4, 13-4a)
Side View
Spherical surface
comes this side.
Spherical surface
Relay lens
unit
A
A
Holder
B
B
B
B
Relay lens
Plate
The printed marker comes this side.
Fig.13-4
Fig.13-4a
13
-3
Condenser lens unit removal.
1. Remove 2 screws-A and remove the Condenser lens unit.
2. Remove 4 screws-B, remove the plate and remove the Condenser lens.
(See Fig.13-3, 13-3a)
A
A
Condenser-lens
unit
Holder
Plate
Condenser lens
B
B
B
B
Flat surface
plane comes this side
* Lens should be placed as the flat surface side
comes to the Holder side.
Fig.13-3
Fig.13-3a
Optical Unit Disassemblies
Содержание PLC-XF46E
Страница 102: ... 102 IC Block Diagrams CXA2019AQ Video Decoder IC3141 CXA2101AQ Multi Component Processor IC4101 ...
Страница 103: ... 103 IC Block Diagrams CXA2151Q RGB Matrix IC2261 CXD2064Q 3 Line Y C Separator IC2101 ...
Страница 104: ... 104 IC Block Diagrams LA7217 Sync Separator IC2051 IC8041 ML60851 USB Interface IC9801 ICS1523M Clock Driver IC4231 ...
Страница 106: ... 106 IC Block Diagrams Sii169ACT DVI Interface IC8001 PW365 Scan Converter IC301 ...
Страница 107: ... 107 IC Block Diagrams TA1318N Sync Separator Frequency Counter IC1061 TC90A11F 3D Noise Reduction IC5101 ...
Страница 112: ... 112 75 88 88 88 88 73 74 76 60 59 65 64 66 90 67 66 62 91 Fig 89 Fig 90 Mechanical and Optical Parts ...
Страница 115: ... 115 114 115 102 103 114 119 118 122 117 121 112 125 Fig 95 Mirrors Fig 96 Lenses Mechanical and Optical Parts ...
Страница 159: ... 159 MEMO ...
Страница 160: ... PLC XF46N E MAY 2006 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 186: ...Diagrams Drawings PLC XF46N XF46E ...