Customizing the status list
Changing the status column indication
1
Select
Column selection
from
System
menu. The col-
umn selection window will appear.
2
On the window, check the column name to be indi-
cated on the status list.
0
The mark [*] next to the column name indicates alert
item.
3
To change the order of the display column on the
status list, select a column you intend to change the
order and click
To up
or
To down
button.
4
Click
OK
to close setting.
0
When specifying the column width by numeric value, enter
number (0 to 9999) onto "Column width" text box.
Column
Description
*Target name
............................Name of the network equipment
*Group
...........................................Group name
*Connect
......................................Status of connection to the network (Connected, Un-connected)
*Drive time
.................................Accumulated use time of the equipment
*Power status
............................ Power status of the equipment (Normal(Power-on), Normal(Standby), Power
Management, Power failure, lamp failure, etc.)
*Input status
..............................Input signal status (Signal, No signal, Signal interrupted)
*Inside Temperature
A status
....................................Status of inside temperature A (Normal, Warning, Error)
*Inside Temperature
B status
....................................Status of inside temperature B (Normal, Warning, Error)
*Inside Temperature
C status
....................................Status of inside temperature C (Normal, Error)
*External Temperature
status
.........................................Status of external temperature (Normal, Warning, Error)
*Lamp1 status
..........................Status of Lamp1 (Off, On, Error, Replace)
*Lamp2 status
..........................Status of Lamp2 (Off, On, Error, Replace)
*Lamp3 status
..........................Status of Lamp3 (Off, On, Error, Replace)
*Lamp4 status
..........................Status of Lamp4 (Off, On, Error, Replace)
*Lamp1 time
..............................Used time of Lamp1
*Lamp2 time
..............................Used time of Lamp2
*Lamp3 time
..............................Used time of Lamp3
*Lamp4 time
..............................Used time of Lamp4
*Filter status
...............................Status of airfilter (Normal, Clogged)
*Option Box
filter status
............................Status of option box filter (Normal, Error, Clogged)
*Filter time
..................................Use time of airfilter
*Option Box
filter time
................................Use time of option box filter
0
The values in parentheses are typical value and they differ depending on the connected equipment.
0
The [*] next to the column name indicates alert items.
Customizing the status list
Specifies col-
umn width