-22-
■
Lamp Replacement
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can
become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can shat-
ter and cause injury.
Procedure
1. Turn off the projector and disconnect the AC cord,. Allow the projector to
cool for at lease 45 minutes.
2. Remove a screw with a screwdriver and remove the lamp cover.
3. Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
4. Replace the lamp assembly securely and tighten 2 screws.
5. Place the lamp cover and tighten a screw.
6. Connect the AC cord to the projector and turn on.
Note:
- Do not reset the LAMP REPLACEMENT MONITOR TIMER, except after
the lamp is replaced.
- The projector can not be turned-on with the lamp cover removed,
because when the lamp cover is removed, the interlock switch is also
released to switch off the mains power for safety.
7. Reset the lamp replacement monitor timer, see below explanation.
Service Parts No.: 610 280 6939
Description: Lamp Assy (POA-LMP21J)
How to reset the lamp replacement moni-
tor timer
1. Turn the projector on. Press the MENU button on the
projector and the On-Screen menu will appear. Select
setting menu and select “Lamp age” on the setting
menu of menu bar.
2. “Lamp replace monitor Reset?” is displayed for confir-
mation.Select “Yes” to reset the lamp replace timer.
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
How to check the lamp replace monitor
time
The LAMP REPLACEMENT indicator will illuminate
when the accumulated illumination time of the lamp
reaches 1000 hours. This is to indicate that lamp
replacement is necessary.
You can check the accumulated illumination time of
the lamp by following procedure.
1. Press and hold the pointer
▲
on the projector for
more than 20 seconds.
2. The projector enters to the service mode and the
accumulated time is displayed in the Data column
with hours unit. For example, when “123” is dis-
played, the accumulated illumination time of the
lamp is 123 hours. This will disappear in 5 seconds.
Lamp cover
Lamp Assembly
Handle
Video
Item
Data
Service Mode
36
123
Accumulated illumi-
nation time of lamp
Содержание PLC-SU20B
Страница 45: ... 45 TPDVS V SYNC TPDHS H SYNC TP3571 NRS ...
Страница 49: ... 49 IC Block Diagrams CXA2111R LCD Driver IC401 CXA2112R Sample Hold IC501 IC531 IC561 ...
Страница 50: ... 50 IC Block Diagrams CXD3503R White Uniformity Compensation IC471 FA5331M Power Factor Control IC01 ...
Страница 51: ... 51 IC Block Diagrams IDT71V016S RAM IC805 LA7217M Sync Separator IC6131 ...
Страница 52: ... 52 IC Block Diagrams LB1641 Motor Drive IC5501 IC5551 LC4105V Buffer IC3501 IC3521 IC3541 ...
Страница 53: ... 53 IC Block Diagrams M62358FP DAC IC431 MB40988PFQ D A COnverter IC2200 ...
Страница 54: ... 54 IC Block Diagrams MC14538BF IC7201 MPC948FA Clock Driver IC1302 ...
Страница 55: ... 55 IC Block Diagrams PW264 System Control Scan Converter IC301 STR Z2156 Power SWitching Control IC631 ...
Страница 58: ... 58 TDA9178T Picture Improvement IC121 IC Block Diagrams ...
Страница 81: ...Ref No Part No Description Ref No Part No Description 81 Electrical Parts List ...
Страница 84: ...Mechanical Parts List 84 CHASSIS PARTS 24 45 24 72 73 71 57 45 45 45 46 46 46 46 51 51 51 ...
Страница 85: ... 85 Mechanical Parts List 32 59 33 58 25 34 28 60 27 45 45 45 45 45 45 ...
Страница 88: ...Feb 2000 1300 SI Printed in Japan SANYO Electric Co Ltd ...