-70-
Electrical Adjustment
Group/Item Item Name
Function
Initial
Range
Note
6 Temp B Warning (Normal)
Temp B (Lamp) to judge the Failure at Normal Mode
67
67
67
67
30-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal
Ceiling
Off
L1
L2
Off
Normal
Up
Down
On
Ceiling
Up
Down
Slant
Ceiling
Definition of Slant
Off
-20° ~ 20°
L1
20° ~ 160°
L2
-20° ~ -160°
7 Temp C Warning (Normal)
Temp C (Panel) to judge the Failure at Normal Mode
52
52
52
52
30-100
8 Temp B-A Warning (Normal)
Temp B-A (Clog) to judge the Failure at Normal Mode
100
100
100
100
0-100
9 Temp C-A Warning (Normal)
Temp C-A (Clog) to judge the Failure at Normal Mode
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp A (Room) to judge the Failure at Eco Mode
47
47
47
47
30-100
11 Temp B Warning (Eco)
Temp B (Lamp) to judge the Failure at Eco Mode
67
67
67
67
30-100
12 Temp C Warning (Eco)
Temp C (Panel) to judge the Failure at Eco Mode
51
51
51
51
30-100
13 Temp B-A Warning (Eco)
Temp B-A (Clog) to judge the Failure at Eco Mode
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp C-A (Clog) to judge the Failure at Eco Mode
100
100
100
100
0-100
15 Temp A Warning Offset (Temp)
Offset of Temp of Temp Error (Temp)
Offset Error Temp under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
10
0-100
16 Temp B Warning Offset (Temp)
11
0-100
17 Temp C Warning Offset (Temp)
13
0-100
18 Temp B-A Warning Offset (Temp)
11
0-100
19 Temp C-A Warning Offset (Temp)
13
0-100
20 Temp A Warning Offset (Time)
Offset of Temp of Temp Error (min)
Offset Error Time under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
30
0-40
21 Temp B Warning Offset (Time)
15
0-40
22 Temp C Warning Offset (Time)
15
0-40
23 Temp B-A Warning Offset (Time)
15
0-40
24 Temp C-A Warning Offset (Time)
15
0-40
254
Fan Control Range Setting (Temp/Frequency)
Norm
Ceil
Up
Down
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal
Ceiling
Off
L1
L2
Off
Normal
Up
Down
On
Ceiling
Up
Down
Slant
Ceiling
Definition of Slant
Off
-20° ~ 20°
L1
20° ~ 160°
L2
-20° ~ -160°
0 High Fan Control Min Temp
Temp Sensor Control Start/End Temp. at High
30
30
30
30
20-100
1 High Fan Control Max Temp
39
39
39
39
20-100
2 High Fan1 Min
Fan Operation Frequency (Min/Max) Setting at High
(rpm)
2775
2775
2775
2775
0000-9990
3 High Fan1 Max
2975
2975
2975
2975
0000-9990
4 High Fan2 Min
1800
1800
1800
1800
0000-9990
5 High Fan2 Max
2555
2555
2555
2555
0000-9990
6 High Fan3 Min
4700
4700
5900
5900
0000-9990
7 High Fan3 Max
4800
4800
6100
6100
0000-9990
8 High Fan4 Min
3120
3120
3120
3120
0000-9990
9 High Fan4 Max
5865
5865
5865
5865
0000-9990
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp. at Normal
30
30
30
30
20-100
11 Normal Fan Control Max Temp
39
39
39
39
20-100
12 Normal Fan1 Min
Fan Operation Frequency (Min/Max) Setting at Normal
(rpm)
2495
2495
2495
2495
0000-9990
13 Normal Fan1 Max
2795
2795
2795
2795
0000-9990
14 Normal Fan2 Min
1625
1625
1625
1625
0000-9990
15 Normal Fan2 Max
2245
2245
2245
2245
0000-9990
16 Normal Fan3 Min
3650
3650
4850
4850
0000-9990
17 Normal Fan3 Max
3725
3725
5000
5000
0000-9990
18 Normal Fan4 Min
2605
2605
2605
2605
0000-9990
19 Normal Fan4 Max
5275
5275
5275
5275
0000-9990
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp. at Eco
30
30
30
30
20-100
21 Eco Fan Control Max Temp
39
39
39
39
20-100
22 Eco Fan1 Min
Fan Operation Frequency (Min/Max) Setting at Eco (rpm)
2210
2210
2210
2210
0000-9990
23 Eco Fan1 Max
2610
2610
2610
2610
0000-9990
24 Eco Fan2 Min
1450
1450
1450
1450
0000-9990
25 Eco Fan2 Max
1935
1935
1935
1935
0000-9990
26 Eco Fan3 Min
2600
2600
3800
3800
0000-9990
27 Eco Fan3 Max
2650
2650
3900
3900
0000-9990
28 Eco Fan4 Min
2090
2090
2090
2090
0000-9990
29 Eco Fan4 Max
4685
4685
4685
4685
0000-9990
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (x0.1)
55
0-255
1 Fan2 Initial Volt
65
0-255
2 Fan3 Initial Volt
35
0-255
3 Fan4 Initial Pulse
Fan Start Output
700
0-4095
4
5
6
7
8 Cooling Time
Cooling Time Setting (x30)
1: 30, 3: 90, 15: 45 sec.
3
1-15
9
10 Temp Error Cooling Time
Cooling Setting at Temp Error (x30)
1: 30, 3: 90, 15: 45 sec.
3
1-15
11 OnStaart Cooling Start Threshold
38
0-100
12 After shutdown cooling
0: No, 1: Yes
1
0-1
256
Fan Lamp Voltage Setting
Содержание PLC-ET30L
Страница 97: ... 97 IC Block Diagrams BA7078 Sync Seperator IC5321 FA7701V Switching Controller IC5641 ...
Страница 98: ... 98 IC Block Diagrams HIN202EIB RS 232C Driver IC3801 ISL51002 10 bit Video A D IC6201 ...
Страница 99: ... 99 IC Block Diagrams L3E07200 LVDS Interface IC501 IC531 IC561 L3E07120 Digital Gamma Shift LCD Driver IC401 ...
Страница 100: ... 100 IC Block Diagrams LM4889 Audio Output IC5121 NJW1141 Audio Control IC5001 ...
Страница 101: ... 101 IC Block Diagrams TE7783 Parallel I O Expander IC1801 PW392 Scan Converter System Control IC301 ...
Страница 102: ... 102 IC Block Diagrams THS7347IPHPR PC1 PC2 SW IC5201 ...
Страница 105: ... 105 Parts Location Diagrams KF7 ET30L00 Condenser lens out assembly M08 L15 Relay lens out assembly L19 M09 ...
Страница 108: ... 108 Parts Location Diagrams KF7 ET30L00 Polarized glass GB L06 L06 ...
Страница 109: ... 109 Parts Location Diagrams KF7 ET30L00 L24 L18 L23 L20 L13 In the Optical Unit L12 L17 L22 L25 L14 L10 L21 L23 L16 ...
Страница 137: ...Key No Part No Description Key No Part No Description KF7 ET30L00 137 Electrical Parts List ...
Страница 138: ... KF7AL Apr 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Страница 150: ...A10 SCH_KF7AL 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA ...