PLC-ET30L Expand Serial Command Functional Specifications
22/62
8.5.8 CF_SETPCADJ Command
Command “CF_SETPCADJ_%1” [CR]
%1
None
“EXT11-60”
Details
1. Apply value set in PC Adjust Menu to projected image.
Specifying setting value directly in the following PC Adjust related commands
immediately reflects them on projected image, while issuing this command after
these commands also triggers the reflection. (Available only in the normal Power
ON status)
・
CF_FSYNC
・
CF_TDOTS
・
CF_CLAMPPAHSE
・
CF_H
−
POS
・
CF_V
−
POS
・
CF_DDOTS
・
CF_DLINE
2. When “EXT11”~”EXT60” is specified in %1, “Ex Mode” (not like XGA1) is
displayed in “SYSTEM” menu.
Response
Acceptable
“000” [CR]
Unacceptable
“101” [CR] --- When input is Video signal / No signal
8.5.9 CF_ORGMODE Command
Command
“CF_ORGMODE_%1” [CR]
%1
When input signal is PC Analog;
“VGA1” ------------------------ Specify VGA1
“VGA2” ------------------------ Specify VGA2
:
:
“XGA1” ------------------------ Specify XGA1
:
:
“WXGA3” --------------------- Specify WXGA3
“1080I60” --------------------- Specify 1080i60
“1080I50” --------------------- Specify 1080i50
“1035I” ------------------------ Specify 10350i
“720p60” --------------------- Specify 720p60
“720p50” --------------------- Specify 720p50
“575p” ------------------------- Specify 575p
“480p” ------------------------- Specify 480p
“575I” -------------------------- Specify 575i
“480I” -------------------------- Specify 480i
* When input signal is not PC Analog, error code “101” is returned.
Details
After “EXT n” is set by PC control command such as CF_FSYNC/CF_TDOTS
and CF_SETPCADJ command, specify the signal originated with by issuing
this command.
This command is used to specify projector internal settings such as whether or
not to get PC signal through IP (Available only in the normal Power ON status)
Note; To differentiate between
60Hz
and
50Hz
in 1080i and 720p, “60” or “50”
is necessary to add to the parameter in this command.
Response
Acceptable
“000” [CR]
Unacceptable
“101” [CR] --- When Input is other than PC Analog