Содержание MCO-420MA

Страница 1: ...MCO 420MA Interface Board INSTRUCTION MANUAL ...

Страница 2: ...1 CONTENTS INTRODUCTION P 2 PRECAUTIONS FOR SAFE OPERATION P 3 COMPONENTS P 5 APPLICABLE EQUIPMENT P 5 INSTALLATION P 6 SPECIFICATIONS P 8 ...

Страница 3: ...nual in an adequate place to refer to it as necessary The contents of the manual will be subjected to change without notice due to the improvement of performance or functions Contact Sanyo sales representative or agent if any page of the manual is lost or page order is incorrect Contact Sanyo sales representative or agent if any point in this manual is unclear or if there are any inaccuracies No p...

Страница 4: ...ther person Precautions are illustrated in the following way WARNING Failure to observe WARNING signs could result in a hazard to personnel possibly resulting in serious injury or death CAUTION Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property Symbol shows this symbol means caution this symbol means an action is prohibited this symb...

Страница 5: ...ized person may result in fire or injury due to a malfunction This manual includes the description for the interface board MCO 420MA only For other information such as the explanation regarding to equipment in which the interface board is to be installed refer to an instruction manual provided with each equipment The data acquired by this interface board never verify the specifications nor perform...

Страница 6: ...necting MCO 420MA with a product from which analog data is acquired Note Connecting cable between a product and this connector is enclosed APPLICABLE EQUIPMENT The interface board MCO 420MA is applicable to equipment listed below CO2 incubator MCO 20AIC But O2 cannot be output MCO 18AIC But O2 cannot be output MCO 18M MCO 5AC But O2 cannot be output MCO 5M MCO 80IC But O2 cannot be output MCO 19AI...

Страница 7: ...all MCO 420MA to its intended location in the equipment from which analog data is acquired by following the procedure below Installation except for MCO 80IC 1 By removing two screws remove the cover on the installation location Fig 1 2 Insert the connector of an enclosed connecting cable into the location A B and C Fig 2 A Connector on the back of the MCO 420MA B Connector CN7 on a main board C Pi...

Страница 8: ...nector of an enclosed connecting cable into the location A Fig 5 and B C Fig 6 A Connector on the back of the MCO 420MA B Connector CN7 on the main board C Pin TP2 on the main board for 24V power supply 3 Fix MCO 420MA to its intended location by using enclosed four screws Fig 7 Fig 7 Cover Fig 4 MCO 420MA Fig 5 B Fig 6 A MCO 420AM C ...

Страница 9: ...l 3 Ch for Temperature CO2 and O2 data Input Voltage Range 0 100mV Output Current Range 4 20mA Span adjustment Adjustment volume for each channel 3 0 Maximum load resistance 800 Ω Power source DC 24 V supplied from a main board via enclosed connecting cable Weight 0 15 kg Accessory 4 screws Note Design or specifications will be subject to change without notice ...

Страница 10: ...7FB6P101460001 2 February 2009 5 5 Keihan Hondori 2 Chome Moriguchi City Osaka 570 8677 Japan Printed in Japan ...