Troubleshooting

If your air conditioner does not work properly, first check the following points before requesting service. If it

still does not work properly, contact your dealer or service center.

Trouble

Possible Cause

Remedy

Air conditioner does not

run at all.

1. Power failure.

1. Restore power.

2. Leakage circuit breaker tripped.

2. Contact service center.

3. Line voltage is too low.

3. Consult your electrician or dealer.

4. Operation button is OFF.

4. Press the button again.

5. Batteries in remote control unit have

run down.

5. Replace batteries.

OPERATION lamp flashes

and air conditioner does

not operate.

Trouble in wiring system.

Contact service center.

Compressor runs but

soon stops.

Obstruction in front of condenser coil.

Remove obstruction.

Poor cooling

performance.

1. Dirty or clogged air filter.

1. Clean air filter to improve airflow.

2. Heat source or many people in

room.

2. Eliminate heat source if possible.

3. Doors and/or windows are open.

3. Shut them to keep the heat out.

4. Obstacle near air intake or air

discharge port.

4. Remove it to ensure good airflow.

5. Thermostat is set too high for

cooling.

5. Set the temperature lower.

Clicking sound is heard

from the air conditioner.

In cooling and drying operation, any

plastic parts may expand or shrink due

to a sudden temperature change. In

this event, a clicking sound may occur.

This is normal, and the sound will

soon disappear.

OPERATION lamp lights

but outdoor unit will not

run.

1. The use of portable telephones near

the air conditioner may cause

disturbance to its normal operation.

1. Turn off the power then restart the

air conditioner after 1 minute.

2. Consult your dealer.

Operating Range

The air conditioner is operable within the temperature ranges as listed below:

Temperature

Indoor Air Intake Temperature

Outdoor Air Intake Temperature

Cooling Model

Maximum

95 °F DB/71 °F WB

115 °F DB

Minimum

67 °F DB/57 °F WB

67 °F DB

Low Ambient

Temperature

Model

Maximum

95 °F DB/71 °F WB

115 °F DB

Minimum

67 °F DB/57 °F WB

0 °F DB

24

OI-330-24EG

oi330000

SANYO FISHER COMPANY
A DIVISION OF SANYO NORTH AMERICA CORPORATION
21605 Plummer Street
Chatsworth, CA 91311 U.S.A.

In Canada
SANYO Canada Inc.
300 Applewood Crescent,
Concord, Ontario,
L4K 5C7, Canada

oi330000

Содержание KS0951

Страница 1: ...INSTRUCTION MANUAL Split System Air Conditioner COOL DRY Model KS0951 KS1251 KS1852 Save These Instructions Pub OI 85264180330005 SANYO 2002 Printed on Recycled Paper ...

Страница 2: ...tomatically turn off the unit at any time after one hour Night Setback Pressing this button changes the setting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This function moves a flap up and down in the air outlet directing air in a sweeping motion around the ...

Страница 3: ...ng 23 Troubleshooting 24 Operating Range 24 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dangerou...

Страница 4: ...ugh the supply wiring 3 Wiring must be done by a qualified electrician Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Never us...

Страница 5: ...ut of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power on off operation mode selection temperature fan speed timer setting night setback and air sweeping Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain Hose Moisture in the room condenses and drains off through this h...

Страница 6: ...en servicing the air conditioner CAUTION Do not set the operation selector at the TEST position for normal operation OPERATION lamp This lamp lights when the system is in the continuous DRY and COOL mode TIMER lamp This lamp lights when the system is being controlled by the timer OPERATION TIMER ON OFF TEST OPERATION lamp Operation selector Remote control receiver INDOOR UNIT KS1852 TIMER lamp IMP...

Страница 7: ...ransmission 7 Flap Angle indication Sweep indication ON OFF 1HR Symbols 7 OI 330 07EG 24 hour clock with ON OFF program Timer Displayed when transmitting data TEMP is displayed when setting temperature Displayed when temperature is shown Displayed when the temperature setting is at the upper or lower allowable limit Displayed when setting timer Displayed when main unit sensor is in use ROOM TEMP i...

Страница 8: ...or inside the remote control unit senses the room temperature Display Information on the operating conditions is displayed while the remote control unit is switched on If the unit is turned off only the mode that was set previously is still displayed NIGHT SETBACK button For details see Night Setback Mode When you press this button in the DRY or COOL mode the mark appears in the display and the re...

Страница 9: ...to pre operation status Always press this button after replacing the batteries ADDRESS switch Change the address switch to prevent mixing of signals from remote control units when two Sanyo air conditioners are installed next to each other Normally the address switch is set to A When switching the address the remote control must be changed and the jumper cables on the indoor unit board must be cut...

Страница 10: ... operated either from a non fixed position or from a wall mounted position To ensure that the air conditioner operates correctly DO NOT install the remote control unit in the following places DO NOT In direct sunlight Behind a curtain or other places where it is covered More than 26 feet 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely ...

Страница 11: ... Do not place objects which may block the transmitted signals between the receiver and the remote control unit Securing the remote 1 Attach the holder to the wall with one screw in the upper hole only control unit to prevent theft 2 Remove the cover from the remote control unit and then remove the batteries Next place the remote control unit in the holder 3 Secure both the remote control unit and ...

Страница 12: ...lector button and select the desired mode For drying operation For cooling operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the temperature setting buttons to change the temperature setting to the desired temperature Adjustable temperature range 86 F max 60 F min NOTE The temperature setting changes by two degrees each time the button is pressed The air ...

Страница 13: ...ting the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level Cooling and DRY mode When difference between room temperature and set temperature is FAN SPEED 4 F and over High Between 4 F and 2 F Medium Below 2 F Low B Manual If you want to adjust fan speed manually during operatio...

Страница 14: ...Y Mode and When the night setback mode is selected the air conditioner automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regardless of the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gen...

Страница 15: ...r is turned on again the unit restarts within five minutes Clicking Sound Clicking sound is heard from the air conditioner In cooling and drying operation any plastic parts may expand or shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear Remote Control Unit The remote control unit sends the setting condition to the ai...

Страница 16: ... symbol after 10 sec 1 2 4 3 2 How to set the OFF time Example To stop the air conditioner at 11 30 pm 1 Press the Program button once 2 Press the HH button until PM 11 is displayed Press the MM button until 30 is displayed 3 Press the ON OFF button to start the air conditioner 4 Press theTIMER SELECT button to set OFF time The timer indication blinks and present OFF time is shown The display will...

Страница 17: ...art operation at 7 10 am and stop the air conditioner at 11 30 pm 1 Set the timer ON OFF times as shown in 2 1 2 and 3 1 2 2 Press the ON OFF button to start the air conditioner 3 Press theTIMER SELECT button to set the ON OFF combination timer NOTE You can check the timer ON OFF times after you have set them by pressing the PROGRAM button The present time PM 9 10 and are displayed OFF time Presen...

Страница 18: ... and then press the ON OFF operation button again The 1 HourTimer function is now cancelled and the unit operates normally NOTE If while the 1 HourTimer function is operating the 1 HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops 2 OperationTogether with the ProgramTimer The 1 Hour OFFTimer setti...

Страница 19: ...mum capacity is obtained at the position at A Sweep function B Setting the airflow manually The flap starts moving up and down to deliver air over the sweep range Referring to the above illustration use the FLAP button to set the airflow direction within the range used during the cooling or drying operation NOTE The flap automatically closes when the unit is off CAUTION Use the FLAP button on the ...

Страница 20: ...clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with a mild liquid detergent When cleaning the grille be careful not to force the vanes out of place CAUTION 1 Never u...

Страница 21: ...cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and dry it How to replace the anti mold filter 1 With the FRONT mark facing you slide the anti mold filter up into the unit and then lower the handle into the groove on the unit 2 After installing the anti mold filter press the locations marked by the arrows and close ...

Страница 22: ...s Otherwise there is a risk of suffocation in extreme cases How to install the air cleaning filter The air cleaning filter needs to be installed behind the anti mold filter 1 Remove the anti mold filter 2 To mount the STK F4B set the air clean filter sold separately at the mounting position with the black side facing the rear To mount the STK ARF4B mount the air clean filter in the position shown ...

Страница 23: ...ipe away any remaining moisture Neutral detergent may be used to remove stubborn dirt Then rinse thoroughly with water and wipe away any remaining moisture Tips for Energy Saving Do not Block the air intake and outlet of the unit If they are obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the r...

Страница 24: ... air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling 5 Set the temperature lower Clicking sound is heard from the air conditioner In cooling and drying operation any plastic parts may expand or shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear OPERATION lamp li...

Отзывы: