HOW TO INSTALL THE STAND

Installation 

screws

1

Remove the covers on the outer 

sides of the arm rests.

Insert the flathead screwdriver into the 

holes under the cover and pull toward 

you. (4 places)

5

Put the cords of the remote control 

and sensor controller in the cord 

hook on the back of the body.

2

Secure the stand on the left-hand 

side of the arm rest, using the 

installation screws (3 screws).

3

Place the covers on the outer sides 

of the arm rests.

Install the cover A on the left-hand side, 

and cover B on the right-hand side.

6

Put the remote control on the 

remote control stand (upper part). 

Put the sensor controller on the 

sensor controller stand (lower part).

Put the remote control on the remote 

control stand in a tilted position as the 

arrow 

 shows, and then push it in the 

direction of arrow 

.

7

Put the cords of the remote control 

and the sensor controller in the 

hooks of the sensor controller stand.

The post holder in the 

lower part of the sensor 

controller stand has 

hooks on both sides. 

Place the sensor 

controller cord with 

the stopper in the hook 

closer to the arm rest. 

Place the remote control 

cord in the opposite 

hook. 

4

Uninstall the cord hook from the 

right-hand side of the arm rest, 

and install it on the left-hand side. 

Remote control

Sensor controller

Remote control 

stand

Sensor controller stand

① 

Uninstall

 

Install

 

Thread the cord

① 

Uninstall

② 

Install

Installation 

screws

Tools needed: Phillips (crosshead) screwdriver, flathead screwdriver

 (

screwdrivers are not included)

Installation on the right-hand side of the chair

Installation on the left-hand side of the chair

1

Remove the cover of the right-hand 

side of the arm rest.

Insert the flathead screwdriver into the 

holes under the cover and pull toward 

you. (4 places)

2

Secure the stand on the right-hand 

side of the arm rest, using the 

installation screws (3 screws).

3

Place the cover on the right-hand 

side of the arm rest.

4

Put the remote control on the 

remote control stand (upper part). 

Put the sensor controller on the 

sensor controller stand (lower part).

Put the remote control on the remote 

control stand in a tilted position as the 

arrow 

 shows, and then push it in the 

direction of arrow 

.

5

Put the cords of the remote control 

and the sensor controller in the 

hooks of the sensor controller stand.

The post holder in the lower part of the 

sensor controller stand has hooks on both 

sides. Place the sensor controller cord with 

the stopper in the hook closer to the arm 

rest. Place the remote control cord in the 

opposite hook. 

Tools needed: Phillips (crosshead) screwdriver, flathead screwdriver

 (

screwdrivers are not included)

Remote control

Sensor controller

Remote control 

stand

Sensor controller stand

Sensor 

controller

Remote control

Sensor controller stand

Remote control

Sensor controller

Sensor controller stand

Cover A

Cover A

① 

Insert

② 

Pull toward you.

Cover B

Remote control cord,

Sensor controller cord

Cord hook

Stopper

Arm rest

Hook

Post

Post holder

Содержание HEC-DR7700BR - Zero Gravity Massage Chair

Страница 1: ...d in the appropriate model s instruction manual or B the repair of any product whose serial number has been altered defaced or removed This warranty shall not apply to the following items non electrical mechanical attachments accessories damage to head cover back pad arm covers seat cover foot rest cover when not caused by defects in workmanship This warranty shall not apply to setup installation ...

Страница 2: ...ssager Do not allow any personnel other than a qualified repair technician to dismantle or repair the massager Otherwise fire electric shock or injury may occur Ask the sales agent if repairs are required Do not attempt to damage break modify bend forcibly pull twist or bundle the cord In addition do not put heavy objects on the cord or jam the cord between objects Otherwise the cord may break res...

Страница 3: ...ut always by holding the power plug and pulling it out Also clean the dust off the power plug periodically Otherwise electric shock short circuit or fire may occur Switch the power OFF instantly if there is a power failure and also pull the power plug out from the outlet Otherwise it may become dangerous when the power is restored Do not move the massager with a person on it Otherwise the massager...

Страница 4: ...d off SOLE WARMER button Used for switching the sole heater operation ON OFF When the heater switch is ON the lamp is illuminated HOME POSITION button Used to return the back rest foot rest and seat to their home positions ZERO G button Used to adjust the back rest foot rest and seat to the two preset zero gravity positions INSTANT STOP button Used if you have felt abnormal physical sensation or w...

Страница 5: ...re to remove the power plug from the outlet Be careful not to step on the power cord remote control or sensor during movement Be sure to move the massager with the assistance of another person on an easily damaged floor surface or concrete surface Moreover when moving the massager like this be sure not to move it with the foot rest extended NOTE Place the massager on a level floor surface Keep the...

Страница 6: ...ll Install Installation screws Tools needed Phillips crosshead screwdriver flathead screwdriver screwdrivers are not included Installation on the right hand side of the chair Installation on the left hand side of the chair 1 Remove the cover of the right hand side of the arm rest Insert the flathead screwdriver into the holes under the cover and pull toward you 4 places 2 Secure the stand on the r...

Страница 7: ...o the ON position Check that there is neither breakage nor damage to the cords Check that the cords are not caught between the back rest and the arm rest and that they are not placed beneath the massager 2Check the power cord remote control cord and sensor controller cord CAUTION when massaging At first do not attempt to select a strong method of massaging until you are accustomed to massaging Do ...

Страница 8: ...ers Do not attempt to climb onto or off the seat by stepping on the foot rest Do not attempt to place anything upon or sit on the foot rest The user may fall over resulting in an accident or injury NOTE For safety check the position of the massaging rollers before leaning slowly back on the massager Do not twist the body but lean straight back on the massager so that the massaging rollers are in p...

Страница 9: ...he whole body RECOVERY Tapping massage to ease muscle fatigue FINE Massage to promote blood circulation Press When the room temperature is low such as in winter it takes some time to warm up or you may barely feel heat Be sure to place your fingers on the sensor The degree of stiffness cannot be measured if your fingers are not placed on the sensor The sensor lamp will flicker and the characters o...

Страница 10: ... move to the upper position and remain in that position After the movement repeat the operation from the beginning of each massage Press the button for the current operation If you continue to press the button until the illumination of the lower body strength scale turns off you can turn off the massaging of the lower body If you press the button the massaging will resume Adjusting the strength of...

Страница 11: ...es the position of shoulder Position too high Position too low Appropriate position Massaging rollers Remote control display When the button is pressed the lamp of the remote control illuminates and the sole warmer will turn on When the foot rest is fully lowered the foot rest will rise a little When the massaging rollers are not located in the upper section the massaging rollers will move to the ...

Страница 12: ...is pressed continuously 6Press the desired MANUAL UPPER BODY MASSAGING button Finishes the massaging automatically by timer operation 5Press the MANUAL button 1 4 7 7 3 5 6 2 7 MANUAL button MANUAL UPPER BODY MASSAGING buttons 4Open the cover of the remote control Cover Post Hook Post Hook When the button is pressed the lamp of the remote control illuminates and the sole warmer will turn on When t...

Страница 13: ...h are adjustable MASSAGING MANUAL COURSES During massaging operation you can change to a different manual massage Whole Body Sensor Automatic Course or Automatic Course Simultaneous massaging of any part of upper body and lower body air is possible Independent massaging of upper body and lower body air is possible 1 to 5 are the same operation for massaging the upper body When massaging the upper ...

Страница 14: ...OFF position and the LOCK switch to the LOCK position When the equipment will not be used for an extended period be sure to disconnect the power plug from the outlet CAUTION Back rest Hook and loop fastener Head cover Head cover Back pad Towel ADJUSTING MASSAGE INTENSITY Use the massager after placing a towel etc on the back pad When the massage is too strong When the massage is too weak Flip the ...

Страница 15: ...on in a simplified manner Also the drawings of air massage operation for lower body are all omitted Sensor massage Shiatsu Shoulder Spine stretching Standard massage in STIFFNESS Course Standard massage in RELAX Course Standard massage in RECOVERY Course Shiatsu Back Grasping shoulder massaging Shoulder Spine stretching Shiatsu Neck Sensor massage Tapping Shoulder Back Waist Tapping Kneading Shoul...

Страница 16: ...rest with the foot rest slide lever pulled Adjust the foot rest with the foot rest slide lever pulled The foot rest cannot be stored Check that the foot rest is not extended Return the foot rest by pulling the foot rest slide lever Check if your fingers are placed on the sensor The degree of stiffness cannot be measured correctly Slightly moisten the fingers using hand cream and place the fingers ...

Отзывы: