- 1 -
- TABLE OF CONTENTS -
Adjustment Procedures ............................................. 1
Specifications ............................................................ 2
Power output Measurement ....................................... 2
Precautions and Repair Service Tips ......................... 2
Circuit Diagram .......................................................... 3
Test Procedures and Troubleshooting......................4-10
Disassembly Instructions .................................... 11-14
Exploded View and Parts List ............................. 15-22
Control Circuit
Board.................................................23
1. ADJUSTMENT PROCEDURES
TO AVOID POSSIBLE EXPOSURE TO MICROWAVE
ENERGY LEAKAGE, THE FOLLOWING ADJUST-
MENTS OF THE INTERLOCK SWITCHES SHOULD
BE MADE ONLY BY AUTHORIZED SERVICE PER-
SONNEL.
PRIMARY INTERLOCK SWITCH, INTERLOCK MONI-
TOR SWITCH AND DOOR SENSING SWITCH AD-
JUSTMENT
(Figure 1)
(1) Loosen 2 screws securing the lever stopper.
(2) Adjust the lever stopper position so that it is pushed
up and pull backward until there is about zero gap
between the latch lever and the switch body on the
door primary interlock switch and the at the same
time there is about zero gap between latch lever
and the switch body on the door sensing switch
when the door latch is securely locked.
(3) Tighten the lever stopper screws securely.
(4) Make sure the interlock monitor switch closes af
-
ter
the primary interlock switch opens the door is
opened
very slowly, according to “CHECKOUT
PROCEDURE
FOR SWITCHES” on page 6.
(5) Make sure the interlock monitor switch opens be
-
fore
the primary interlock switch closes when the
door is
closed very slowly, according to CHECK
-
OUT PRO
CEDURE FOR SWITCHES” on page 7.
CAUTION
MICROWAVE RADIATION
PERSONNEL SHOULD NOT BE EXPLOSED TO THE
MICROWAVE ENERGY WHICH MAY RADIATE FROM
THE MAGNETRON OR OTHER MICROWAVE GENE-
RATING DEVICE IF IT IS IMPROPERLY USE OR
CONNECTED. ALL INPUT MICROWAVE CONNEC-
TIONS, WAVEGUIDE, FLANGES, AND GASKETS
MUST BE SECURE. NEVER OPERATE THE DEVICE
WITHOUT A MICROWAVE ENERGY ABSORBING
LOAD ATTACHED. NEVER LOOK INTO AN OPEN
WAVEGUIDE OR ANTENNA WHILE THE DEVICE IS
ENERGIZED.
(6) Make sure the microwave energy leakage should be
no greater than 5 mW/cm
2
to allow to measurement
uncertainty when measured with a detector.
(All service adjustments must be made for minimum
microwave energy leakage readings.)
NOTE: If the interlock monitor circuit operates and at
the same time the fuse blows with the door
opened, be sure to replace the control circuit
board because relay 3 and 4 on the control cir-
cuit board, the door sensing switch and the elec-
tric circuit related on the door sensing switch,
which act as Secondary Interlock switch.
Interlock monitor
switch
Lever stopper
Latch Lever
Primary Interlock
switch
Latch Lever
Door sensing
switch
Figure 1
Screws
Overall Circuit Dia
gram........................................24-25
Содержание EM-C1900M
Страница 5: ......
Страница 7: ......
Страница 8: ... 7 ...
Страница 11: ......
Страница 18: ......
Страница 23: ......
Страница 26: ... 25 CONTROL CIRCUIT BOARD Figure 12 ...
Страница 27: ... 26 ...
Страница 28: ... 27 SANYO Electric Co Ltd OSAKA Japan ...