- 2 -
3. TEST PROCEDURES AND TROUBLESHOOTING
CAUTION
-DISCONNECT THE POWER SUPPLY CORD FROM THE WALL
OUTLET WHENEVER REMOVING THE CABINET FROM THE UNIT.
PROCEED WITH TESTS ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITORS AND REMOVING THE LEAD WIRES ON
THE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORM-
ERS FOR LOWER AND UPPER MAGNETRONS.
(SEE FIGURE 1)
COMPONENT
HIGH-VOLTAGE
TRANSFORMER
1) Measure the resistance:
With an ohm-meter on R x1 scale.
a. Primary winding;
b. Filament winding;
c. Secondary winding;
2) Measure the resistance:
with an ohm-meter on highest scale.
a. Primary winding to ground;
b. Filament winding to ground;
CHECKOUT PROCEDURE
RESULT
Normal reading:
Approximately 1.0 ohms
Less than 1 ohm.
Approximately 50 ohms
Normal reading:
Infinite ohms.
Infinite ohms.
Note: Remove varnish of measured point.
PRIMARY
WINDINGS
Secondary
Windings
Filament
Windings
Figure 1
Figure 2
A. TEST PROCEDURES