GENERAL
This set has an On-screen Service Menu system included in the CPU that allows remote operation for most of the service adjustments.
ON-SCREEN SERVICE MENU SYSTEM
1. Enter the Service Menu:
•
While pressing the MENU key, reconnect the AC power cord. The Service Menu Display will now appear. (See Figure 1.)
2. Service Adjustments:
•
Press the
▲
or
▼
key to select the desired service menu you want to adjust. (See page 4 for On-screen Service Menu.)
•
Use the + or – key to adjust the data.
3. Exit from the Service Menu:
•
Press the MENU key to turn off the Service Menu display.
SERVICE ADJUSTMENTS
— 3 —
IC802 (EEPROM) REPLACEMENT
When IC802 (EEPROM) is replaced, IC801 (CPU) will automatically write the initial reference data into IC802 for basic TV operation.
However, the bus data should be checked and some bus data should be set up before attempting the service adjustments.
(See pages 4 – 6 for detailed information.)
INITIAL BUS DATA SETUP
Note: When IC802 (EEPROM) is replaced, the Service Menu NO. 03 HP (H Phase), NO. 05 VPO (V Position), NO. 07 VLN
(V Lin), NO. 23 POS (Preshoot Overshoot Switch), NO. 28 PRE (Preshoot Adj), NO. 29 WP (White Peak Limiter),
NO. 32 BSG (Black Str Gain), NO. 34 DCR (DC Reset), NO. 37 AF (Auto Flesh), NO. 41 RYA (R-Y/B-Y Angle), NO 48
EWA (E/W Amp), NO. 49 EWT (E/W Tilt), NO. 50 EWP (E/W Corner Top), NO. 51 EWB (E/W Corner Bottom), NO. 52
HSC (Horz Size Comp), NO. 55 STI ( Sub Tint), NO. 57 OPT (SA Option ), and NO. 58 OP2 (SA Option 2) should be
set up for proper TV operation before attempting the service adjustments.
1. Disconnect the AC power cord (AC 120V line).
2. While pressing the MENU key, reconnect the AC power cord. The Service Menu display will now appear.
3. Select NO. 03 HP (H Phase) with
▲
or
▼
key. Adjust the data with + or – key for 13.
4. Select NO. 05 VPO (V Position) with
▲
or
▼
key. Adjust the data with + or – key for 20.
5. Select NO. 07 VLN (V Lin) with
▲
or
▼
key. Adjust the data with + or – key for 20.
6. Select NO. 23 POS (Pre/Over Switch) with
▲
or
▼
key. Adjust the data with + or – key for 1.
7. Select NO. 28 PRE (Preshoot Adj) with
▲
or
▼
key. Adjust the data with + or – key for 3.
8. Select NO. 29 WP (White Peak Limiter) with
▲
or
▼
key. Adjust the data with + or – key for 1.
9. Select NO. 32 BSG (Black Str Gain) with
▲
or
▼
key. Adjust the data with + or – key for 2.
10. Select NO. 34 DCR (DC Reset) with
▲
or
▼
key. Adjust the data with + or – key for 1.
11. Select NO. 37 AF (Auto Flesh) with
▲
or
▼
key. Adjust the data with + or – key for 1.
12. Select NO. 41 RYA (R-Y/B-Y Angle) with
▲
or
▼
key. Adjust the data with + or – key for 2.
13. Select NO. 48 EWA (EW Amp) with
▲
or
▼
key. Adjust the data with + or – key for 26.
14. Select NO. 49 EWT (EW Tilt) with
▲
or
▼
key. Adjust the data with + or – key for 33.
15. Select NO. 50 EWP (EW Corner Top) with
▲
or
▼
key. Adjust the data with + or – key for 9.
16. Select NO. 51 EWB (EW Corner Bottom) with
▲
or
▼
key. Adjust the data with + or – key for 10.
17. Select NO. 52 HSC (Horz Size Comp) with
▲
or
▼
key. Adjust data with + or – key for 5.
18. Select NO. 55 STI (Sub Tint) with
▲
or
▼
key. Adjust the data with + or – key for 14.
19. Select NO. 57 OPT (SA Option ) with
▲
or
▼
key. Adjust the data with + or – key for 16.
20. Select NO. 58 OP2 (SA Option 2) with
▲
or
▼
key. Adjust the data with + or – key for 66.
21. Press the MENU key to turn off the Service Menu display.
NO.
DATA
XX OPT XXX XXXXXXXX
Figure 1. Service Menu Display
ITEM NO.
TITLE
BINARY DATA
(8 bit)
DECIMAL DATA