No.
TITLE
INITIAL REFERENCE
INITIAL SETUP
RANGE OF DATA
FUNCTION
DATA
DATA
1
HFR
1E
1E
00~3F
Horizontal Frequency
2
AFC
00
00
00, 01
AFC Gain and Gate
3
HP
0E
0E
00~1F
Horizontal Phase (Horizontal Centering)
4
VS
32
40*
00~7F
Vertical Size
5
VPO
05
05
00~3F
Vertical Position
6
VSP
00
00
00, 01
Vertical Set Up (Sync Sensitivity)
7
VLN
13
13
00~1F
Vertical Linearity
8
CRS
00
00
00~03
Cross B/W
9
GRY
01
01
00, 01
Grey Mode
10
VSC
08
07*
00~1F
Vertical S Correction
11
HBR
03
03
00~07
Horizontal Blanking Right
12
HBL
04
04
00~07
Horizontal Blanking Left
13
CDM
00
00
00, 01
Color Difference Mode
14
VC
07
07
00~07
Vertical Compression
15
RB
00
00
00~FF
Red Bias
16
GB
00
00
00~FF
Green Bias
17
BB
00
00
00~FF
Blue Bias
18
RD
40
40
00~7F
Red Drive
19
GD
08
08
00~0F
Green Drive Reduction
20
BD
40
40
00~7F
Blue Drive
21
SBI
40
30
00~7F
Sub Bias
22
OSD
02
02
00~03
On Screen Display Contrast
23
POS
01
01
00, 01
Preshoot Overshoot Switch
24
FLS
01
01
00, 01
Filter System
25
CKO
03
03
00~07
Color Killer Operation
26
GYA
00
00
00, 01
G-Y Angle
27
CRG
02
02
00~03
Corring Gain
28
PRE
03
02*
00~03
Preshoot Adjust
29
WP
01
01
00, 01
White Peak Limiter
01: OFF 00: ON
30
FSW
00
00
00, o1
Flyback Blanking Switch
31
VBL
00
00
00, 01
Vertical Blanking Switch
32
BSG
01
02*
00~03
Black Stretch Gain
33
BSS
01
01
00~03
Black Stretch Start
34
DCR
01
01
00~03
DC Reset
35
YGM
01
01
00~03
Y Gamma Start
36
CBP
00
00
00, 01
C Bypass
37
AF
01
01
00, 01
Auto Flesh
0: OFF 1: ON
38
BAT
04
04
00~07
Bright ABL Threshold
39
MSD
00
00
00, 01
Mid Stop Defeat
40
ABL
00
00
00, 01
ABL Defeat
0: OFF 1: ON
41
RYA
02
02
00~0F
R-Y/B-Y Angle
42
RAD
0F
20*
00~3F
RF AGC Delay
43
IAS
00
00
00. 01
IF AGC Switch
0: TV (Normal) 1: AV (IF Gain Minimum)
44
FMM
00
00
00, 01
FM Mute
— 4 —
Table 1. ON-SCREEN SERVICE MENU
When IC802 (EEPROM) is replaced, check the bus data to confirm they are the same as below. The shaded menu should be
checked and be set up or readjusted according to the procedures described in the following pages. Initial Setup Data marked
with an * should be changed from Initial Reference Data. (See page 3 for Initial Bus Data Setup.)