SERVICE ADJUSTMENTS (Continued)
— 5 —
PROGRAM CODES
The microprocessor used in this model is a multi-purpose type
and is used in several different models. To ensure proper
operation and the correct features for your particular model, the
Program Codes must be correct.
Note 1. Option Data 1 (No. 029 OPT) should be decimal 0
(00000000 binary). See page 3 INITIAL DATA SETUP, step 9,
for set up procedure. If this program code is wrong the TV will
not operate properly.
Note 2. Option Data 2 (NO. 030 OP2) should be decimal 0
(00000000 binary). If this program code is wrong the TV will not
operate properly.
Note 3. Red/Blue Drive Adjustments in Service Menu No.
041 DRV: Adjust Red and Blue Drive Levels alternately with 1,
3, 7, and 9 keys on the remote control. (See figure 2.) The Drive
Level adjustment data will be written in the Service Menu No.
011 and 012 automatically.
1
2
3
4
5
6
7
9
8
RB(–)
RB(+)
BB(–)
BB(+)
(N/A)
GB(–)
(N/A)
GB(+)
(N/A)
FOR RED BIAS ADJUSTMENT
FOR BLUE BIAS ADJUSTMENT
FOR GREEN BIAS ADJUSTMENT
Figure 2.
Figure 3.
1
2
3
4
5
6
7
9
8
RD(–)
RD(+)
BD(–)
BD(+)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
FOR RED DRIVE ADJUSTMENT
FOR BLUE DRIVE ADJUSTMENT
BIT
FUNCTION
DATA
0
1
0
TV/HOTEL
TV
HOTEL
1
NOT USED
N/A
2
NOT USED
N/A
3
NOT USED
N/A
4
NOT USED
N/A
5
NOT USED
N/A
6
NOT USED
N/A
7
NOT USED
N/A
Note 4. Red/Green/Blue Bias Adjustments in Service Menu
No. 042: Adjust each Bias Level with 1, 3, 4, 6, 7, or 9 key on
the remote control. (See figure 3.) The Bias Level adjustment
data will be written in the Service Menu No. 008 ~ 010
automatically.
BIT
FUNCTION
DATA
0
1
0
NOT USED
N/A
1
NOT USED
N/A
2
NOT USED
N/A
3
NOT USED
N/A
4
NOT USED
N/A
5
NOT USED
N/A
6
NOT USED
N/A
7
NOT USED
N/A
Содержание DS13310, DS19310