– 5 –
POWER FAILURE CIRCUIT
Check the following if the unit is turned off by the power
failure detector.
1. Disconnect the AC power cord (120V AC line) for a short
time.
2. Connect a DC Voltmeter to the circuits shown below.
3. Press the Power key and check for the proper voltage
supplies.
4. If any of these voltages is low, the power failure detec-
tor should turn the unit off within three seconds.
5. Check all circuits shown below.
Note
: If power failure is detected 3 times in 15 minutes,
the set will enter the standby mode and cannot be
switched On.To reset the operating programs of the
CPU it is necessary to disconnect the AC cord for a
short time.
CPU (IC800) is programmed so the set will go to standby
mode when there is circuit failure as described below.
(Refer to“Block Diagram Power Lines”.)
This unit is equipped with a Power Failure Detector function
included in the CPU which checks for an abnormal condi-
tion in the chassis power supplies.
If, while the power is on, a failure is caused by any of the
following that results in a low voltage supply, the CPU will
turn the unit off in 1.5 seconds to prevent further damage:
•
Failure within the power supply circuits.
•
A short circuit in the load side from the supply.
Power Failure:
Detected voltage failure for circuit.
(Connected to IC800 pin 48 and pin 23.)
(Normal: High; Failure: Low)
If, while the power is off, the power is switched on and any
of these failures remains uncorrected, the CPU will shut off
the power within three seconds.
48
18
IC800 (SUB-CPU)
4,2
3
23
Power Fail 1
Power On
Power Fail 2
1
Power Board
Inverter
Main
D1671
K8B
D1660
D1681
Audio_Pow
13V
IC1660
9V
12V
5V
STAND BY
D1621
3
D1620
IC1630
3.3V
Содержание DP50741
Страница 33: ... 29 IC1640 IC5730 DC to DC Converter IC BLOCK DIAGRAMS CONT IC801 EEPROM ...
Страница 35: ... 31 IC5500 Block Diagram IC BLOCK DIAGRAMS CONT IC6200 Low output Amplifier ...
Страница 36: ... 32 IC8500 USB Protection IC5700 DDR Double Data Rate SDRAM ...
Страница 45: ... 41 IC DIODE AND TRANSISTOR PIN LAYOUTS ...