- 4 -
SERVICE MODE
4. Setting REGION code
4.1 While a highlighted indicator is displayed on the right side
of the Region denotation, push ENT, and each button
on the remote controller. With each push the indicator will
advance as shown below.
1 <-> 2 <-> 3 <-> 4 <-> 5 <-> 6
5. Saving settings
5.1 Make sure that the Market and Region settings are properly
set.
(If any of the settings are incorrect, you can make a change
by moving the indicator using
o
button, and following
procedures 3 and 4 above. )
5.2 After ensuring that the settings are all correct, push ENT
button while the indicator is on Exit area. The settings are
now saved.
6. Finishing settings
6.1 After a few seconds, the Internal Setup screen disappears,
and then the Service Mode screen is displayed again for
three seconds as shown on the right.
You should check the settings.
Region
2
Market
BackendVersion S31204A2
Loader Version 17
Z09
Y03
Value
6.2 Power OFF.
Internal Setup
Market
00
Region 1
Exit
00-WM 01-SFC 02-UK 03-XE 04-S18
05- SS 06-PA 07-AU 08-CN 09-JP
10-FXE 11-MX 12-NT
1
Internal Setup
Market
00
Region
1
00-WM 01-SFC 02-UK 03-XE 04-S18
05- SS 06-PA 07-AU 08-CN 09-JP
10-FXE 11-MX 12-NT
Exit
Backend version
S 31204 A 2
Brand (S : SANYO , F : FISHER)
Version ( 2 0 0 2 . 12 . 25)
Sub Version (A,B,......Z)
Region ( 0 : Region undefined
1 ~ 6 : Region defined )
Loader Version (17 Z09 Y03)
(Reference figure)
(Reference figure)
(Reference figure)
4.2 Set up the region coder currently displayed on the set.
4.3 Once the desired number is displayed, push
p
button to
move the highlighted indicator to Exit area.
The sample of a display of a region
code.
3