-20-
Purity and Convergence Adjustment
CONVERGENCE ADJUSTMENT
Preparation: After carrying out purity adjustment and
before proceeding to convergence
adjustment, provisionally insert the rubber
wedge so that there is no vertical or
sideways play in the deflection yoke.
Signals: Display a crosshatch pattern.
1. Red/blue centre adjustment
Adjust the angle between the tabs (1) and (2) in Figure
5 and rotate them together until the lines of the red and
blue crosshatch patterns (vertical and horizontal lines)
are superimposed in the centre of the screen.
2. Green and red/blue centre adjustment
Adjust the angle between the tabs (3) and (4) in Figure
5 and rotate them together until the lines of the green
crosshatch pattern are superimposed with the red/blue
crosshatch pattern (vertical and horizontal lines) which
were superimposed in step 1).
3. Vertical lines at screen centre (Red and Blue)
Use the VR2 control (see Figure 8) at the top of the
deflection yoke to correct the vertical line convergence
at the centre of the screen.(See Figure 9.)
4. Vertical lines at screen top and bottom
Use the VR1 control (see Figure 8) at the top of the
deflection yoke to correct the vertical line convergence
at the top and bottom of the screen. (See Figure 10.)
5. Horizontal lines at screen top and bottom
Rotate the Deflection yoke to the left or right to correct
the horizontal line convergence at the top and bottom of
the screen. (See Figure 11.)
If vertical lines are intersecting at the top and bottom,
use a screwdriver to adjust the Balance coil at the top of
the deflection yoke. (See Figure 12.)
Red
Blue
Figure 6
Red/Blue
Green
Figure 7
Red
Blue
Figure 9
Figure 5
Adjust the angle rotation of tabs
(1) and (2) to align the vertical
and horizontal lines.
Adjust the angle and rotation of
tabs (3) and (4) to align the vertical
and horizontal lines.
Use the VR2 control to correct.
Red
Blue
Figure 10
Use the VR1 control to correct.
Blue
Red
Figure 11
Rotate the DY to correct.
Blue
Red
Figure 12
Use the Balance coil to correct
1
2
3 4
SIX-POLE
MAGNET TABS
FOUR-POLE
MAGNET TABS
ANGLE
OF TABS
PURITY
MAGNET
TABS
Balance
coil
VR1
VR2
Figure 8
SM_29-C8ZH (RUS) 5/15/06 12:05 PM Page 20