Adjustment in the Service Mode
-14-
5. Adjust level of 300Hz at TP317 to become minimum by pressing the / -) button on the remote
control or TV set.
Minimum leakage
TP317 (R)
300Hz
6. Select “HI SEPARATION” by pressing the CHANNEL UP/DOWN button on the remote control or TV set.
7. Adjust level of 4KHz at TP318 to become minimum by pressing the VOLUME (+/-) button on the remote
control or TV set.
8. To exit from the service mode, press the MENU button.
SAP VCO Adjustment
1. Connect a frequency counter to TP317 (C3437, + side) on the
Main Board and ground.
2. Ground TP-20 (Base of Q131) with the jumper lead. (Setting
of no signal condition.)
3. Ground TP-316 (C3411, side +) with the jumper lead through
1M
Ω
resistor.
4. Switch the TV set on.
5. Press and hold the MENU button on the TV set, then press
“3” button on the remote control transmitter to enter to the
Service Mode.
6. Select “SAP VCO” by pressing the CHANNEL UP/DOWN
button on the remote control or TV set.
7. Adjust frequency of the counter to become 78.125KHz ±0.5KHz
by pressing the VOLUME (+/-) button on the remote control or
TV set.
8. To exit from the service mode, press the MENU button.
TP318 (L)
Minimum leakage
4KHz
INPUT LEVEL 25
STEREO VCO 23
FILTER 32
LOW SEPARATION 29
HI SEPARATION 26
SAP VCO 27
INPUT LEVEL 25
STEREO VCO 23
FILTER 32
LOW SEPARATION 29
HI SEPARATION 26
SAP VCO 27