SAFETY PRECAUTIONS

WARNING:

Service should not be attempted by anyone unfamiliar with the necessary precautions for this recording or playback
equipment. The following precautions are necessary during servicing:

1.

Many electrical and mechanical parts in this recorder have
special safety-related characteristics for providing protec-
tion against shock, fire and other hazards. These charac-
teristics often go unnoticed in a visual inspection, and the
protection afforded by them cannot necessarily be ob-
tained by using replacement components with higher rat-
ings (voltage, wattage, etc.).

2.

Replacement parts having special safety-related charac-
teristics are identified in this manual, and in the schematic
diagrams, by the symbol  !  . These components have
values that are of special significance to product safety.
Should any component (identified by the symbol      ) need
to be replaced, use only the part designated in the parts
List. Do not deviate from the specified resistance, wattage,
and voltage ratings.

3.

Before returning the set to the customer, always perform an
AC leakage current check on the exposed metallic parts of
the cabinet, such as terminals, screwheads, metal over-
lays, etc. to be sure that the set is safe to operate without
the danger of electrical shock, Plug the AC line cord directly
into a 120 V AC outlet. (Do not use a line isolation trans-
former during this check.) Use an AC voltmeter with a
sensitivity of 5000 ohms per volt (or more) as follows:
Connect a 1500 ohms, 10 watt resistor, paralleled by a 0.15
mfd, 150 VAC capacitor, between a known good earth
ground (water pipe, conduit, etc.) and the exposed metallic
parts, one at a time. Measure the AC voltage across the
1500 ohms resistor and 0.15 mfd capacitor combination.
Reverse the AC plug at the AC outlet and repeat the AC
voltage measurements for each exposed metallic part. The
measured  voltage  must  not  exceed  300  mVrms.  This
corresponds to 200 

µ

A AC. Any value exceeding this limit

constitutes a potential shock hazard and must be corrected
immediately.

4.

Fuse symbol marks.
For CANADA

UNDERWRITERS LABORATORIES Standard

CAUTION  

"Risk of fire-replace fuse as marked"

For U.S.A.

Fuse rating is marked at
adjacent fuse.

Video

Monitor

Содержание 114 901 11

Страница 1: ...3 N S P Not available as service parts Design and specifications are subject to change without notice Product Code 114 901 11 U S A Canada SERVICE MANUAL B W Video Monitor CONTENTS SPECIFICATIONS 3 1 OPERATING INSTRUCTIONS 5 2 SERVICE ADJUSTMENTS 7 3 PARTS LIST 9 4 CIRCUIT DIAGRAMS 13 Product Code 114 901 14 Europe VM 6609P Product Code 114 901 16 U K Product Code 114 901 18 Australia ...

Страница 2: ...gs 3 Before returning the set to the customer always perform an AC leakage current check on the exposed metallic parts of the cabinet such as terminals screwheads metal over lays etc to be sure that the set is safe to operate without the danger of electrical shock Plug the AC line cord directly into a 120 V AC outlet Do not use a line isolation trans former during this check Use an AC voltmeter wi...

Страница 3: ... control Termination switch Operating environment Power source Power consumption Dimension W x H x D Weight CCIR standard 9 measured diagonally 90 deflection angle More than 800 TV lines center Horizontal 15 625 kHz CCIR Vertical 50 Hz CCIR Composite video 1 line BNC connector 1 0 V p p 75 ohm negative sync Composite video 1 line BNC connector 1 0 V p p 75 ohm negative sync Composite video 1 line ...

Страница 4: ... 4 Fig 2 W D H DISASSEMBLY 1 1 1 1 1 1 1 1 METAL TOP COVER Fig 1 ...

Страница 5: ...Video input terminals VIDEO IN These terminals are used to input a video signal source to this monitor Connect to the video output of a VCR or an other monitor for loop through connection or to a video camera 3 Video output terminals VIDEO OUT These terminals are used to output a video signal from this monitor Loop through output of the video in BNC connector then connect to the video input of ano...

Страница 6: ...Video B INPUT terminal Video signal cable To Video A INPUT terminal Video signal cable Rear panel To Video input terminal To Video input terminal Monitor Video recorder Fig 4 Monitor Video recorder To Video input terminal Coaxial cable Video camera Fig 6 1 3 2 5 4 7 6 ...

Страница 7: ...ment tool Adjust L402 to make picture width within 2 position Adjust the vertical linearity control VR301 for equal spaceing of lines between the center extreme of scan The focus control may be adjusted for optimum focus by VR405 The raster is centered by rotating the two small at the rear of the yoke Loosen the screw on the rear of deflection yoke rotating the yoke to correct position tighten the...

Страница 8: ...SUB BRITE VR302 V SIZE VR405 FOCUS T403 L402 Q405 E C B VR304 SUB SIZE VR301 V LINE VR303 INTERLACE VR406 BRIGHTNESS SW901 LED1 VR201 CONTRAST SW202 CHANNEL MAIN BOARD VR BOARD Fig 8 Fig 9 MAIN BOARD Foil side VR BOARD Foil side ...

Страница 9: ...PAD RIVET MM 9M GL 19 B 13 645 046 0753 CRT MI0908P4AU CPT 14 645 034 3599 PH W W SCR 4 18MM 15 645 046 1057 VIDEO BOARD MT 9S 16 645 046 0975 METAL TOP COVER MT 9 AA 51 17 645 034 3582 PH W W SCR 4 8MM 18 645 034 3841 ID LABEL 83 51MM N S P 19 645 046 1064 MAIN BOARD MM 9S 20 645 046 0982 JACK PLATE MT 9S AA 51 21 645 035 6216 BH SCREW 4 6MM 22 645 034 3612 SCREW WASHER 3 6MM 23 645 046 0593 CRT ...

Страница 10: ...04 645 046 0272 RECTIFIER DIODE BYT56J D405 645 034 3346 RECTIFIER DIODE BYT52M T52MM D406 645 046 0265 RECTIFIER DIODE PS106R T D407 645 046 0265 RECTIFIER DIODE PS106R T D408 645 034 3315 DIODE 1N4148 T 52MM OR 645 034 3308 DIODE 1N4148 T D901 645 046 0241 RECTIFIER DIODE 1N4007 T 52MM D902 645 046 0241 RECTIFIER DIODE 1N4007 T 52MM D903 645 046 0241 RECTIFIER DIODE 1N4007 T 52MM D904 645 046 02...

Страница 11: ... 645 034 2318 CF RES 680OHM 1 4W 5 T 52MM R919 645 034 1878 CF RES 10KOHM 1 4W 5 T 52MM R921 645 034 1878 CF RES 10KOHM 1 4W 5 T 52MM R922 645 045 9924 W W RES 3 9OHM 3W 5 5MM SWITCH SW201 645 046 0418 SLIDE SWITCH SS004 P012BJ PA6 TRANSFORMERS T401 645 046 0777 DRIVE TRANS VM 14AF OR 645 046 0784 DRIVE TRANS VM 14AF OR 645 046 0791 DRIVE TRANS VM 14AF T403 645 046 0807 FBT TRANS MM 9M T901 645 04...

Страница 12: ...R 500OHM 9DIA 10MM ND F 15 MISCELLANEOUS B703 645 046 0388 CONNECTOR BASE M241854 B206 645 046 0654 SHIELD WIRE 2547 26AWG 645 046 0647 L W HOUSING 1007 24 L 220 B901 645 046 0623 L W HOUSING 1015 18AWG ACCESSORIES PACKING MATERIALS 1 645 038 5933 POWER CORD NS8 5175N VM 6609 1 645 034 3971 POWER CORD 10 1VDE VM 6609P XE 1 645 040 9264 POWER CORD NS8 5181N VM 6609P UK 1 645 040 9257 POWER CORD NS8...

Страница 13: ...R POWER LED B404 2 3 4 B206 BRIGHT_VR 4 3 5 1 2 3 2 1 B403 B204 VR402 R421 R914 GND R211 C203 R233 VR PWB RED WHITE YELLOW BLACK RED BLUE RED RED 2 4 6 B202 R221 C213 R227 YELLOW WHITE ORANGE 1 2 3 5 B203 C212 Q203 C214 12V Q201 WHITE RED GREEN BLUE D406 VR405 R228 D408 L404 C207 MAIN PWB MAIN PWB VIDEO PWB ...

Страница 14: ... 14 1 2 3 4 5 6 7 8 A B C D E F G H I J K CRT MAIN_PWB VIDEO_PWB VIDEO_PWB VR_PWB VR_PWB MAIN_PWB VR_PWB MAIN CIRCUIT DIAGRAM ...

Страница 15: ...903 22K 5W D906 BA159 L903 20µH C908 0 1µ 100V C905 4700P 400VAC IC901 D905 PG106R R909 100 D907 FG106R R908 2 2K R906 1K Q902 2SC1213 R919 10K Q903 TL431 R918 680 Q901 2SC3866 L N G MAIN_PWB MAIN_PWB ZR901 R922 3 9 3W C904 4700P 400VAC VR_PWB C907 0 01µ 1KV T902 R905 1K R912 51 ZD901 6C2 R904 47K C925 0 1µ 100V R915 4 75K R916 1 2K R920 NONE R921 10K C920 1000µ 16V R914 1K VR_PWB C912 1000µ 16V C...

Страница 16: ......

Страница 17: ......

Страница 18: ...Feb 01 2300 MI Printed in Japan SANYO Electric Co Ltd Osaka Japan ...

Страница 19: ...board monitors software tv dvd and othes Manual users user manuals user guide manual owners manual instruction manual manual owner manual owner s manual guide manual operation operating manual user s manual operating instructions manual operators manual operator manual product documentation manual user maintenance brochure user reference pdf manual ...

Отзывы: