SY265C LC/SY265C LR Excavator OMM
3-14
Operation and Maintenance Manual — 0420
SANY
SWITCHES
The following are on the right control console:
•
Key switch (1). See “Key Switch” on page 3-14.
•
Throttle control dial (2). See “Throttle Control
Dial” on page 3-15.
•
Work light switch (3). See “Work Light Switch” on
page 3-15.
•
Windshield wiper switch (4). See “Windshield
Wiper Switch” on page 3-16.
•
Windshield washer switch (5). See “Windshield
Washer Switch” on page 3-17.
•
Beacon light switch (6). See “Beacon Light
Switch” on page 3-17.
•
Travel alarm silence switch (7). The travel alarm
silence switch will silence the travel alarm until
travel is stopped. This switch does not cancel or
reset any machine alarm. See “Travel Alarm
Silence Switch” on page 3-17.
•
Regeneration inhibit switch (8). See “Regeneration Inhibit Switch” on page 3-18.
•
Stationary regeneration switch (9). See “Stationary Regeneration Switch” on page 3-19.
Key Switch
The key switch is used for the following functions:
•
HEAT (1) — Hold the key to HEAT to preheat the
engine for cold weather starting as required. The
key returns to OFF when released.
•
OFF (2) — The OFF position allows the operator
to insert and remove the key. The engine is shut
down, and there is no power to any of the electrical
system switches (except for work lights).
NOTICE!
Except for an emergency, never shut down the engine while it is running at high idle.
Stopping the engine at high idle can damage the machine or cause it to run improperly.
Fig. 3-15
0005311
1
2
3
9
8
6
5
4
7
0005356
1
2
3
4
Fig. 3-16