ABOUT THE PRODUCT

Congratulations on the purchase of your new Sanuvox UV air purifier. Sanuvox UV air purifiers are the most advanced air 

purification systems available, having been proven to destroy up to 99.99% of biological and chemical contaminants that circulate 

throughout the air of your home or facility. Sanuvox systems have been tested by the EPA (Environmental Protection Agency), 

the National Homeland Security research center, medical universities and independent third party laboratories.

For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

COMPONENTS

How it Works

The  Sanuvox  SANUVAIR

®

  S100  unit  is  designed  to  destroy  biological  and  chemical  contaminants. The  air  purifier  can  be 

installed in a suspended celling or on a wall. An internal fan circulates air through the air purifier. The SANUVAIR

®

 S100 is 

designed to treat up to 500 square feet of space (per unit).

A.  Air inlet vent

B.  Filter door (with mesh)

C.  Security switch

D.  Filter

E.  UV Lamp

F. Fan

G.  Unit cover

H.  Air outlet vent

SETUP & INSTALLATION

What you will need

A utility knife to unpack all components, a stepladder to reach the celling or wall properly, a Phillips No.2 screwdriver, a measuring 

tape, a level, a marker, and a cutter or saw (if ceiling-mounted).

 CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, 

install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit 

or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included

The SANUVAIR

®

 S100, a UV lamp and a basic 

installation kit.

The  installation  kit  includes:  a  pair  of  cotton 

gloves, 8-32 screws (3), a transformer, a power 

cord (US or EUR), an elbow adapter, an angled 

support  bracket  and  a  near-horizontal  support 

bracket.

Содержание SANUVAIR S100

Страница 1: ...ollow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrical shock may caus...

Страница 2: ...Setup Installation Ceiling Mounted 4 Step by Step Setup Installation Wall Mounted 6 OPERATION 7 How to Operate your Product 7 MAINTENANCE 8 How to Replace Lamp s 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 Step by Step Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TROUBLESHOOTING 10 What you will need 10 Problems So...

Страница 3: ...nternal fan circulates air through the air purifier The SANUVAIR S100 is designed to treat up to 500 square feet of space per unit A Air inlet vent B Filter door with mesh C Security switch D Filter E UV Lamp F Fan G Unit cover H Air outlet vent SETUP INSTALLATION What you will need A utility knife to unpack all components a stepladder to reach the celling or wall properly a Phillips No 2 screwdri...

Страница 4: ...it out of its box and install the support anchors required to support the unit by screwing them directly to the unit A Sliding door side near horizontal support bracket B Beveled side mesh angled support bracket Then lay the unit on a flat surface with the access doors facing up NOTE Keep box in case of return under warranty STEP 1 STEP 2 STEP 5 5 Install lamp Open the unit by sliding its cover to...

Страница 5: ...device support anchors against the tile and the ceiling support 11 Replace the cut part of the suspended ceiling tile to hide the opening Then right up against the unit install a 24 T bracket Your new SANUVAIR S100 is now ready to operate so you can enjoy great air quality for you and your colleagues 6 Install Filter While the unit cover is still open pull on the non mesh end to gain access to the...

Страница 6: ...ted the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints NOTE Fingerprints on the lamp will negatively impact the UV output of the lamp STEP 3 STEP 4 STEP 5 STEP 6 5 Install lamp Open the unit by sliding its cover...

Страница 7: ...he fan settings are adjusted to your liking make sure to close the unit cover properly OPERATION How to Operate your Product If wired directly to a dedicated power source the SANUVAIR S100 will operate continuously If wired in parallel with other devices such as overhead lighting the SANUVAIR S100 will operate only when the circuit is energized The internal fan circulates air through the device Ro...

Страница 8: ...s doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the new UV lamp out from the cardboard sleeve Be su...

Страница 9: ...ed on the ceiling or wall Another option is to remove the unit from the ceiling or wall and then access the filter with the unit lying on a flat surface with the access doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover and pull on the non mesh end of the filter door to gain access to the filter location CAUTION When unit is wall mounted its...

Страница 10: ...ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT TROUBLESHOOTING If your product is not working properly refer to the following What you will need A stepladder to reach to celling or wall properly and an ohmmeter Problem Possible Ca...

Страница 11: ...s facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have continuity When both sets of pins test good for continuity it can be assumed that the lamp is good STEP...

Страница 12: ...be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure t...

Отзывы: