SUGGESTED INSTALLATION 

Unit could be  

 

Suspended from ceiling with suspension 
rods or chains (not included).  

 

Hung on the wall with angle iron  

Install collar plates on the unit. Note that both are 
distinct. 

Attach ducts (metal or flex) to the return side of 
the unit above the area where smoke 
accumulates to remove smoke as fast as possible. 
Attach ducts (metal or flex) to the supply side of 
the unit to discharge clean air in the room or over 
a door to prevent odors from escaping the room. It is through recirculation that the odors will be 
removed.  You may use multiple inlets to pull the smoke to the unit. 

The VOC controller should be installed on the ceiling where the smoke tends to accumulate. The 
S1000 unit comes with 20ft of wire (Fig3) to link the controller box to the unit. If 20 ft not long 
enough, you can replace it with BX wiring with 3 wires.  

Note that when powering up, it will take 3 minutes until the VOC monitor will be ready to act: LED 
green and red lights will tell you it works. 

IMPORTANT: you may have to calibrate the VOC Monitor: refer to the monitor instructions or call 
Sanuvox. 

WORKING INSTRUCTION 

The VOC controller analyzes the air every 90 seconds. A 20-foot power cord connects it via a relay to 
the device to activate the second oxidizing lamp on demand. 
 
The S1000 VOC unit runs continuously, so its regular lamp purifies the air constantly. This dual zone 
lamp (UVC / UVV) is sufficient when there are only one or two smokers. 
 
However, when the cigarette smoke increases in the room, the VOC controller that samples the air 
at regular intervals, then triggers the 2nd UVV lamp for periods of 90 seconds. This cycle is repeated 
if the controller detects smoke in the room: it then turns off the 2nd lamp, leaving the 1st lamp to 
continue the cleaning cycle.

 

 

 

SIMPLIFIED PROCESS

:  

 

Ashes in the “white” smoke will be trapped onto the filter  

 

Nicotine molecules will be dried by the UVC rays than trapped in the filters without the tar like 

material that coats everything. 

 

VOC will be oxidised by the UVV, reducing substantially their olfactory perception.

 

 

air returned into the room

 

Collecting pipe with openings to grab smoke

 

S-1000 
unit 

air returned into the room

 

Содержание S1000

Страница 1: ... One 1 VOC controller part MSC1A factory s pre set Four 4 replacement pre filters part MSCFTR2 LAMP INSTALLATION this step can be done later 1 Open the front door on the S1000 unit 2 Open the door access to the aluminum box by removing the two wing nuts see picture aside 3 Remove the BLUE END CAP LMPHXJ160 lamp from packaging Use the gloves provided 4 Identify the ballast showing LMPHXJ160 follow ...

Страница 2: ...it works IMPORTANT you may have to calibrate the VOC Monitor refer to the monitor instructions or call Sanuvox WORKING INSTRUCTION The VOC controller analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC ...

Страница 3: ...nic board initializes itself 2 After 5 minutes the GREEN LED will turn solid Blow some cigarette smoke into the controller If the other RED LED lights up the relay triggers on the oxidizing lamp all UVV This sequence reproduce itself every minute or so When there is no more smoke VOC the RED LED is turned off at the same time as the lamp MAINTENANCE INSTRUCTIONS MONTHLY Change the pre filters that...

Страница 4: ... it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However if there is much smoke in the room the VOC controller that samples the air on a regular basis will then trigger the second all UVV lamp for a period of ...

Отзывы: