background image

A

B

C

G

E

D

F

6

Instruction Manual for P900-GX

1-888-726-8869

www.sanuvox.com

OPERATION

How to Operate your Product

The P900-GX is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON and enjoy clean 

air in your home!

 CAUTION:

 The suggested operating temperature range is 10 to 50°C (50 to 122°F). Operating the P900-GX outside this 

range will result in decreased performance. For optimal performance, air temperature moving through the unit should be in the 

range of 15 to 20°C (60 to 70°F).

How to Read the Control Panel Display

The P900-GX control panel display will give you real time status update about its fan speed and timer settings.

Default Settings

When the unit is plugged, all settings are OFF: push the power button to turn on unit.

Default fan speed is set to 3, which is considered the optimum performance.

Default run time is set to “C” (continuous operation).

The fan is always running when the lamp is on.

 CAUTION:

 System is designed to control the TDCEF-05019A12-H-12-BAL 12 Volt brushless DC fan motor. Operation with 

other types of fan may not be optimal and may void the warranty.

You can then select the P900-GX fan speed and operating time at any time to suit your individual preferences.

During operation, the LEDs and display toggle every 5 seconds between TIME and FAN setting display, showing time remaining 

and fan speed. 

Operation will resume at default time/speed whenever unit is turned off and on again.

How to Switch from Default to Timer Mode

1. While the P900-GX is powered ON, press the “Mode Button” to switch between settings. When “Timer Mode LED Indicator” 

flashes, your unit is on “Timer Mode” settings and the numeric digit on the “LED Display Window” corresponds to the time 

left before shutting down.

2. Use the up and down arrow buttons to select run time.

  Run time can be set between 1 to 9 hours or to “C” (Continuous operation).

3. Wait for a short period without touching any buttons for P900-GX to register new settings. Your unit will then start working with 

the timer mode activated.

After the set time has elapsed, lamp, fan and display will turn off.

A.  Up Arrow Button 

B.  LED Display Window

C.  Power ON/OFF Button

D.  Down Arrow Button

E.  Timer Mode LED Indicator

F.  Fan Speed LED Indicator

G.  Mode Button

Содержание P900-GX

Страница 1: ...ollow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrical shock may caus...

Страница 2: ...ON 6 How to Operate your Product 6 How to Read the Control Panel Display 6 Default Settings 6 How to Switch from Default to Timer Mode 6 Step by Step Adjust Fan Speed 7 MAINTENANCE 7 How to Replace Lamp s 7 Step by Step Lamp Replacement 7 How to Clean your Product 9 Step by Step Inlet Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TRO...

Страница 3: ...GX is designed to purify up to 900 square feet destroying chemical and biological contaminants The unit is designed for small homes and apartments and can be used in commercial areas For information or recommendations on how to size your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works Contaminated air enters the P900 GX parallel to the UV J lamp thus increasing c...

Страница 4: ...ctions call SANUVOX at 1 888 726 8869 What s included The P900 GX with its UV lamp and a basic installation kit The installation kit includes a UV caution decal a maintenance decal a stand and an handle with its screw 1 Step by Step Setup Installation 1 Prepare the P900 GX for installation Remove unit from packaging Before plugging the P900 GX turn it face down and place on soft surface to protect...

Страница 5: ...ation Step by Step Handle Installation 1 Loosen the two bottom screws between the two rubber feet 1 The handle fits into the wall handle notch just under the middle rubber foot Slide the handle in and tighten the screw 2 Slide the stand through the two screws and tighten STEP 1 STEP 1 STEP 2 ...

Страница 6: ... brushless DC fan motor Operation with other types of fan may not be optimal and may void the warranty You can then select the P900 GX fan speed and operating time at any time to suit your individual preferences During operation the LEDs and display toggle every 5 seconds between TIME and FAN setting display showing time remaining and fan speed Operation will resume at default time speed whenever ...

Страница 7: ... for detailed step by step instructions CAUTION In order to avoid reduced performance of lamp s do not touch lamp glass without gloves Step by Step Lamp Replacement 1 Unplug P900 GX from wall outlet Turn face down and place on soft surface to protect top of unit CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sourc...

Страница 8: ...ecurity seal on the underside of the cardboard sleeve 6 Press the lamp clamp and insert the new lamp Release lamp clamp to secure lamp in place 7 Holding the ceramic base attach the plug to the new lamp The plug will fit in one direction only It may be necessary to rotate the plug 90 to attach it 8 Replace the lamp access door and secure it with its 4 screws 9 Replace the P900 GX upright or on wal...

Страница 9: ...rcumstance should water be sprayed or splashed onto the product 1 Detach the two thumbscrews on the top of the filter frame with a non magnetic 5 16 nutdriver Then remove the filter frame 3 Remove the aluminum filter and clean it NOTE The filter can be washed in a mild detergent soap and water 5 Replace the plastic grill 2 Remove the plastic inlet grill 4 When filter is dry reinstall it on the inl...

Страница 10: ...NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT Problem Possible Cause Solution Unit doesn t come ON There is no power to the electrical outlet Make sure the power outlet is working Make sure the unit is plugged in to 120V outlet The On Off switch is not ON Pus...

Страница 11: ...top of unit CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources 2 On the back of the P900 GX unscrew the 8 screws along the sides 4 on the left and 4 on the right to open the unit 3 Once unscrewed lift the cover to open the unit Look at the top to see if the motor connection is properly connected STEP 1 STEP 2 ...

Страница 12: ...ion SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters UV bulbs or other accessories if included except for material or workmanship defects Cal...