background image

Sanuvox Technologies Inc, © 2019 All rights reserved. February 2020 EN v.1

Instruction Manual

Photos illustrating products are non contractual.

P900-GX

PORTABLE UV AIR PURIFIER

Residential Model

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in 

this manual before using the product. Failure 

to comply with these instructions may result 

in personal injuries or damage to the unit or 

system.

1.  Installation and servicing of air conditioning 

and related equipment can be hazardous due 

to systems pressure and electrical components. 

Only trained and qualified service personnel

 

should install, repair or service equipment.

2.  Untrained personnel can perform basic 

maintenance functions such as replacing 

lamp(s)  and/or  filter(s).  All  other  operations 

should be performed by trained service 

personnel.

3.  When working on the unit or system, observe 

precautions in the literature, tags and labels 

attached to the unit or system, and all other 

safety precautions considered as best practices 

in the HVAC industry.

4. When applicable, local regulation may 

comprise more restrictive installation and/or 

certification requirements. The afore mentioned 

requirements prevail on those of this document 

and the installer agrees to conform to these at 

his own expense.

5.  Follow all the safety instructions outlined in this 

document and respect all local and national 

codes applicable.

6.  Never expose eyes or skin to ultraviolet light 

from any source.

 Therefore, 

before installing 

or performing maintenance on the unit or 

system,  TURN OFF AND DISCONNECT the 

unit or system from all power sources (there 

may be more than one switch to disconnect).

 

 CAUTION: Electrical shock may cause 

personal injuries or possibly death.

7.  UV  rays  may  destroy  certain  types  of  filters 

(polymer or plastic); please keep the unit or 

system light away from shining directly on 

plastic.

8.  When installing or performing maintenance on 

the UV unit or system, it is recommended to 

wear safety glasses and gloves. In order to 

avoid reduced performance of lamp(s), do not 

touch lamp glass without gloves.

9.  UV lamps contain a small quantity of mercury: 

if a lamp breaks, clean and dispose of with 

care. UV lamps can be disposed/recycled after 

use,  as  any  other  fluorescent  lamps.  Contact 

and  follow  your  local  and  national  authorities’ 

specific instructions.

10. 

Use  only  specified  SANUVOX  branded 

replacement UV lamps with your unit or 

system. Use of any other lamps will void your 

warranty and can result in damage to the unit, 

system and/or lamp(s).

11. Most UV units or systems are not waterproof. 

DO NOT INSTALL OUTDOORS unless 

specified otherwise.

SAVE THESE INSTRUCTIONS

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Содержание P900-GX

Страница 1: ...ollow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrical shock may caus...

Страница 2: ...ON 6 How to Operate your Product 6 How to Read the Control Panel Display 6 Default Settings 6 How to Switch from Default to Timer Mode 6 Step by Step Adjust Fan Speed 7 MAINTENANCE 7 How to Replace Lamp s 7 Step by Step Lamp Replacement 7 How to Clean your Product 9 Step by Step Inlet Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TRO...

Страница 3: ...GX is designed to purify up to 900 square feet destroying chemical and biological contaminants The unit is designed for small homes and apartments and can be used in commercial areas For information or recommendations on how to size your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works Contaminated air enters the P900 GX parallel to the UV J lamp thus increasing c...

Страница 4: ...ctions call SANUVOX at 1 888 726 8869 What s included The P900 GX with its UV lamp and a basic installation kit The installation kit includes a UV caution decal a maintenance decal a stand and an handle with its screw 1 Step by Step Setup Installation 1 Prepare the P900 GX for installation Remove unit from packaging Before plugging the P900 GX turn it face down and place on soft surface to protect...

Страница 5: ...ation Step by Step Handle Installation 1 Loosen the two bottom screws between the two rubber feet 1 The handle fits into the wall handle notch just under the middle rubber foot Slide the handle in and tighten the screw 2 Slide the stand through the two screws and tighten STEP 1 STEP 1 STEP 2 ...

Страница 6: ... brushless DC fan motor Operation with other types of fan may not be optimal and may void the warranty You can then select the P900 GX fan speed and operating time at any time to suit your individual preferences During operation the LEDs and display toggle every 5 seconds between TIME and FAN setting display showing time remaining and fan speed Operation will resume at default time speed whenever ...

Страница 7: ... for detailed step by step instructions CAUTION In order to avoid reduced performance of lamp s do not touch lamp glass without gloves Step by Step Lamp Replacement 1 Unplug P900 GX from wall outlet Turn face down and place on soft surface to protect top of unit CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sourc...

Страница 8: ...ecurity seal on the underside of the cardboard sleeve 6 Press the lamp clamp and insert the new lamp Release lamp clamp to secure lamp in place 7 Holding the ceramic base attach the plug to the new lamp The plug will fit in one direction only It may be necessary to rotate the plug 90 to attach it 8 Replace the lamp access door and secure it with its 4 screws 9 Replace the P900 GX upright or on wal...

Страница 9: ...rcumstance should water be sprayed or splashed onto the product 1 Detach the two thumbscrews on the top of the filter frame with a non magnetic 5 16 nutdriver Then remove the filter frame 3 Remove the aluminum filter and clean it NOTE The filter can be washed in a mild detergent soap and water 5 Replace the plastic grill 2 Remove the plastic inlet grill 4 When filter is dry reinstall it on the inl...

Страница 10: ...NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT Problem Possible Cause Solution Unit doesn t come ON There is no power to the electrical outlet Make sure the power outlet is working Make sure the unit is plugged in to 120V outlet The On Off switch is not ON Pus...

Страница 11: ...top of unit CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources 2 On the back of the P900 GX unscrew the 8 screws along the sides 4 on the left and 4 on the right to open the unit 3 Once unscrewed lift the cover to open the unit Look at the top to see if the motor connection is properly connected STEP 1 STEP 2 ...

Страница 12: ...ion SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters UV bulbs or other accessories if included except for material or workmanship defects Cal...