24
Instruction Manual for ASEPT.1X Max
1-888-726-8869
www.sanuvox.com
6. Disengage the rear lock of the disinfection cassette and gently slide it
out from its tabs.
STEP 6
CLICK!
CLICK!
7. Unscrew the 3 screws at the back of the disinfection cassette and gently
remove the reflector by sliding it out of the front tabs.
8. Note the position of each wire, then disconnect all wiring from the
ballast to be replaced. Use a thin flat screwdriver to assist in removing
the wires from their sockets.
9. Unscrew the old ballast and install the new one. Use an 11/32" or
equivalent hex nut socket.
10. Screw the new ballast in its position and connect all the wires.
11. Replace the reflector and screw it back.
STEP 7
STEP 8
STEP 9
STEP 10
STEP 11