FIGURE 03: WIRING DIAGRAM
OUTLET
INLET
CABLE CLAMP
TERMINAL BLOCK
EARTH POST
ELEMENT
THERMOSTAT CONTROL
FIGURE 02: INTERNAL LAYOUT
DRAIN PLUG
THERMAL CUT-OUT
CAPILLARY STAT
TO ELEMENT
GREEN&YELLOW
BROWN/RED
BLUE/BLACK
EARTH
LIVE (RED)
NEUTRAL (BLACK)
THERMAL FUSE
THERMOSTAT
TERMINAL BLOCK
THERMOSTAT BULB
CABLE
GROMMET
3.3.3
Remove the terminal cover.
3.3.4
Strip the outer sheath and insulation on the cable to the required lengths, push
the cable through the grommet provided, this will be held by the cable grip when
the connections are made (see Figure 02).
3.3.5
Loosen the top screws securing the cable grip.
3.3.6
Pass the cable underneath the cable grip and through the top moulding.
3.3.7
Make the connections to the terminal block as follows:
Live (brown or red wire) to terminal marked “L”
Neutral (blue or black wire) to terminal marked “N”
Earth (green or green/yellow wire) to terminal marked .
3.3.8
Secure the cable in the cable grip by tightening the two screws.
3.3.9
Set the adjustable thermostat by rotating the control to the required temperature.
It is recommended that it is set to lowest acceptable temperature to meet user
requirements. This will minimise the risk of scalding and reduce the level of
scaling in hard water areas.
3.3.10 Replace terminal cover.