SINUS PENTA
GUIDE TO THE
REGENERATIVE APPLICATION
126/
150
5.11.
FieldBus Menu
5.11.1.
Overview
NOTE
For any detail about the communications protocol, the hardware interface, the
implemented functions, etc., please refer to the Fieldbus sections in the Motor
Drives Accessories Guide and Programming Guide.
NOTE
The section below covers the fieldbus operation for the Regenerative application.
5.11.2.
List of Programmable Parameters P330 and P331
Parameter
FUNCTION
User Level
MODBUS
Address
DEFAULT VALUES
P330
Measure 3 from the Fieldbus
ENGINEERING
930
5:
M505
Active Power
P331
Measure 4 from the Fieldbus
ENGINEERING
931
2:
M502
Mains Voltage
Table 25: List of parameters P330 and P331
P330/P331 Measure 3/Measure 4 from Fieldbus
P330
Range
0
91
NONE
M090
Default
6 (
P330
)
3 (
P331
)
M505
Active Power (
P330
)
M502
Mains Voltage (
P331
)
Level
ENGINEERING
Address
930
Function
The user can select Measure 3 and 4 exchanged from the fieldbus
among the measures
M500
to
M090
(see Table 26 below).