background image

 

 

8/12 

ASAC-0 

 

 

6

 

Accessories 

6.1

 

Finger Guard Kit 

Finger guards may be specified for personnel safety.  Finger guards fit over the soft starter terminals to prevent accidental contact with 

live terminals.   Finger guards provide IP20 protection when used with cable of diameter 22 mm or greater. 

 

6.2

 

Remote Operator 

The Remote Operator can control and monitor the soft starter's performance. Functionality includes: 

 

Operational control (Start, Stop, Reset, Quick stop) 

 

Starter status monitoring (Ready, Starting, Running, Stopping, Tripped) 

 

Trip code display 

 

6.3

 

Communication Modules 

ASAC-0 soft starters support network communication via easy-to-install communications modules.   Each soft starter can support one 

communications module at a time. 
Available protocols: 
Ethernet (Profinet, Modbus TCP, Ethernet/IP), Profibus, DeviceNet, Modbus RTU, and USB. 

 

 

NOTE 

Ethernet communication modules are not suitable for use with ASAC starters using 380/440 VAC control voltage. 

 

6.4

 

PC Software 

The software allows comprehensive management of soft starters.  It provides the following functionality: 
Operation of soft starter networks containing up to 254 individual soft starters  

 

Operational control (Start, Stop, Reset, Quick stop) 

 

Starter status monitoring (Ready, Starting, Running, Stopping, Tripped) 

 

To use RemoteDrive with the ASAC-0, the soft starter must be fitted with a USB Module, Modbus Module or a Remote Operator.  

 

Содержание ASAC-0

Страница 1: ...resulting by the use of non original spare parts Enertronica Santerno reserves the right to make any technical changes to this manual and to the device without prior notice If printing errors or simil...

Страница 2: ...ected to mains voltage Only a qualified electrician should carry out the electrical installation Improper installation of the motor or the soft starter may cause equipment failure serious injury or de...

Страница 3: ...090 200 160 240 216 214 114 5 51 6 1 ASAC 0 110 7 87 6 30 9 44 8 50 8 43 4 5 2 0 13 5 2 2 Physical Installation 1 2 3 4 15757 A 1 ASAC 0 007 ASAC 0 055 Allow 100 mm 3 9 inch between soft starters ASA...

Страница 4: ...24 VAC VDC A1 A2 WARNING Always apply control voltage before or with mains voltage CAUTION With 24 VAC VDC use contacts rated for low voltage and low current gold flash or similar 3 3 Control Circuits...

Страница 5: ...3 4 2 Run Output The run output relay terminals 23 24 can be used to signal run status This relay is normally open The relay operates when the soft start is complete the bypass relays are closed and f...

Страница 6: ...time the motor will take to reach full speed 1 Set the start ramp time to 20 seconds 2 Set the initial start voltage as required for the application 3 Attach a current monitoring device to output T1 4...

Страница 7: ...than five seconds while the soft starter is running These trip points are not adjustable In pre start starting and stopping modes the high and low frequency limits both apply with no time delay A supp...

Страница 8: ...support network communication via easy to install communications modules Each soft starter can support one communications module at a time Available protocols Ethernet Profinet Modbus TCP Ethernet IP...

Страница 9: ...age to SCRs from transient overload currents and for Type 2 coordination ASAC 0 soft starters have been tested to achieve Type 2 coordination with semiconductor fuses Suitable Bussmann and Ferraz Mers...

Страница 10: ...60068 Test Fc Sinusoidal 4 Hz to 13 2 Hz 1 mm displacement 13 2 Hz to 200 Hz 0 7 g EMC Emission Equipment class EMC Class B Conducted radio frequency emission 0 15 MHz to 0 5 MHz 56 46 dB V 0 5 MHz t...

Страница 11: ...SAC 0 11 12 7 4 Model Code ASAC 0 Control voltage 1 110 240 VAC 380 440 VAC 2 24 VAC VDC Mains voltage 4 200 440 VAC 5 200 575 VAC Nominal kW rating 400 VAC 007 030 AC53b 4 6 354 037 110 AC53b 4 6 594...

Страница 12: ...12 12 ASAC 0...

Отзывы: