TEMPERATURE LIMIT STOP SET UP
Santec Pressure Balanced Valve has a temperature limit stop ( please
see Illustration C) which once set properly can provide a safe and
comfortable hot water. Below is the limit stop installation procedure:
- Remove all Handle trim parts, including the trimplate.
- Remove all internal parts up to the Limit Stop, do not remove the
Mechanical Stop.
If Mechanical Stop is removed please follow the instruction below:
- Turn the cartridge clockwise until it is stopped. Do not force
to avoid damaging the cartridge.
- Insert the Mechanical Stop onto the catridge.
- Turn the cartridge counterclockwise to open the water line. Turn
until it reaches the maximum hot water desired by the user.
- Place Limit Stop as shown in the Illustration D2.
- Reinstall all the parts accordingly to the Illustration C.
6
3
4
2
11
5
8
7
9
1
10
New
New
New
New
New
PB-3950
Pessured Balanced w/ Diverter (Valid after Jan 2010)
12
13
PM-8 Kit Extension, 20K Broach
PM-9 Kit Extension, 16K Broach
PM-113X DIverter Extension
ITEM
NO.
PART NUMBER
DESCRIPTION
QTY.
1 TE025
(prior to Jan 2010 - TE010)
Cartridge
1
2 TE-015
Valve Cover
1
3 TE013
Limit Stop
1
4 TE014
Limit Stop
1
5 TE011
Screw
4
6 PM-963
(prior to Jan 2010 - PM-009)
Brass Lock Plate
1
7 PM-964 (new)
Mud Guard Holder
1
8 PB-3950-4
Screw
2
9 Mud Guard (not a spare part)
Mud Guard
1
10 Valve Body (not a spare part)
Valve Body
1
11 Diverter Body (not a spare part)
Diverter Body
1
12 PM-1092
Extension
1
13 PB-002/TE060/TE050 (see picture
below
Diverter Cartridge
1
13
TE050
TE060