background image

The measurements shown are for reference only. Products and specifications shown are subject to change without notice.

www.santecfaucet.com   |   P: 310.542.0063   F: 310.542.5681    

2/

3

INSTALLATION INSTRUCTIONS

TRIM INSTALLATION

- Place the shower plate on the all thread.
- Screw the handle escutcheon with the Flange washer onto the all

 

thread.

Press them firmly against the plate and mark the position.

- Remove the handle trim assembly and all th

r

ead and cut off the

excess thread.

-Inset the broach extension onto the valve.

- Insert the Handle onto the broach extension. Measure the excess between

the handle and the

 

trim plate.  Take off the handle and cut the excess stem.

- Reinsert the handle onto the stem.
- Place the Trim Plate Grommet onto the designated hole for the

Diverter Rod on the Trim Plate.

- Screw the Diverter Knob onto the Diverter Rod.

All Thread

Lock Nut

Lock Plate

S

T

Trim Plate Grommet

Diverter Rod

Trim Plate

Handle Trim Assembly

Diverter Knob

Broach Extension

S

T

COLD

HOT

FLANGE WASHER

6

3

4

2

11

5

8

7

9

1

10

New

New

New

New

New

PB-3950

Pessured Balanced w/ Diverter (Valid after Jan 2010)

12

13

PM-8 Kit Extension, 20K Broach

PM-9 Kit Extension, 16K Broach

PM-113X  DIverter Extension

 (Plated)

ITEM

NO.

PART NUMBER

DESCRIPTION

QTY.

1 TE025

 (prior to Jan 2010 -  TE010)

Cartridge

1

2 TE-015

Valve Cover

1

3 TE013

Limit Stop

1

4 TE014

Limit Stop

1

5 TE011

Screw

4

6

 

PM-963

 

(

prior to

 

Jan 2010 PM-009

 N/A

)

Brass Lock Plate

1

7 PM-964 (new)

Mud Guard Holder

1

8 PB-3950-4

Screw

2

9 Mud Guard (not a spare part)

Mud Guard

1

10 Valve Body (not a spare part)

Valve Body

1

11 Diverter Body (not a spare part)

Diverter Body

1

12 PM-1092

Extension

1

13 PB-002/TE060/TE050 (see picture 

below

Diverter Cartridge

1

13

TE050 

          TE060 

PB-002

Отзывы: