MW RADIO SPECIFICATION
Temp 20
0
C Humidity 65 %
A.C 240 V 50Hz D.C 12 V
LOADS 8 ohm Ref.out 50 mW
SAMPLE:
PAGE 3 OF 7
MEASURING ITEMS
CONDITION
UNIT
NORMAL LIMIT
TEST CONDITION
LOW END
KHZ
+/-5
523
HIGH END
KHZ
+/-15
1633
INTERMEDIATE FREQ
KHZ
+/-3
466
600KHZ
dB
1000KHZ
dB
1400KHZ
dB
-20dB QUIETING
600KHZ
dB
SENSITIVITY
1000KHZ
dB
1400KHZ
dB
DIAL CALIBRATION
ALL POINTS
KHZ
<30
POINTER WITHIN LETTERING
600KHZ
dB
>43
1000KHZ
dB
1400KHZ
dB
>44
I.F. REJECTION
600KHZ
dB
>45
-6dB BAND WIDTH
1000KHZ
KHZ
4-8
ACA +/- 10KHZ
1000KHZ
dB
AGC FIGURE OF MERIT
1000KHZ
dB
100dB/M
RF OVERLOAD DIST.
1000KHZ
%
100dB/M 60% MOD
10% DIST. O/P POWER
1000KHZ
MW
*
1KHZ ; 400HZ
80% MOD.
MAX. O/P POWER
1000KHZ
MW
3500
3200
*
1KHZ ; 400HZ
80% MOD.
MAX. O/P. DIS
1000KHZ
%
*
1KHZ ; 400HZ
60% MOD.
-6dB AUDIO
LOW FREQ
HZ
VOL. AT 75% POSITION
FIDELITY
HIGH FREQ
HZ
3K
2K2
3K6
ADJUST MOD .TO REF
2 IF
%
<10
3 IF
%
<10
S/N WITH 74dB/M
1000KHZ
dB
DIST. AT STANDARD O/P
1000KHZ
%
MODULATION HUM 100dB/M
1000KHZ
dB
MIN. VOL. FEEDTHROUGH
NOISE & HUM
MIN. VOL
MV
600KHZ
dB
--
--
1000KHZ
dB
--
--
1400KHZ
dB
--
--
AUTO SEEK ACCURACY
KHZ
--
--
AUTO TUNING SEEK SENS
TWEET AT 1MV/M - 5MV/M
IMAGE REJECTION
MAX.SENSITIVITY
FREQUENCY RANGE