background image

INSTRUCTIONS

SPECIFICATION

MODEL

AUTDISP

OUTER SIZE

L110*W100*H165MM

CAPACITY

700ml

DROP VOLUME

0.8-1ml

WEIGHT

480g

MATERIAL

ABS, AS

BATTERY

5X1.5V “AA”

TECHNICAL PARAMETERS

ELECTRICAL SOURCE VOLTAGE

DC6V

STATIC CURRENT

60UA

WORKING CURRENT

200MA

POWER

4W

EFFECT DISTANCE

0-10CM

Cover

Key

Container

LED lamp

Infrared sensor  

window

Battery compartment

Pump

Power 

on/off

SETUP

FEATURES

  The sensor is at the base of the dispenser with effect 

range of 0-10cm underneath the sensor.

  Continually flashing LED light in standby mode 

indicates battery replacment is necessary.

  This product is not fully waterproof and should not 

be placed in a continually damp environment.

  The dispenser works both inside and outside  

but should be kept out of direct sunlight as this 

can affect the both the sanitiser gel and also the 

function of the sensor.

INSTALLATION AND USE
1.  Slide the dispenser into the mounting plate (figure 1).
2.  Insert batteries into battery compartment with 

polarity as indicated (alkaline batteries are 

recommended).

3.  Open the cover and pour the liquid into the 

container (figure 2).

4.  Put your hand 0-10cm under the sensor and allow 

the dispenser to operate until the sanitiser gel 

runs from the nozzle (figure 3). When using the 

dispenser for the first time you may need to 

activate the dispenser upto 15 times to enable 

the sanitiser gel to work through the pump 

before it will dispense.

5.  Power On/Off button

  First press will turn on giving a standard 

dispense and LED light flashes once.

  Second press will increase to a double 

dispense and LED light flashes twice

  Third press will turn the dispenser off  

and LED light glows for one second

  The two different settings can be used to give 

the right amount of sanitiser gel, ensuring when 

it is thicker in colder conditions an effective 

dose is delivered everytime.

IF THE DISPENSER DOESN’T TURN ON
1.  Check the batteries are inserted with polarity as 

indicated in the battery compartment.

2.  Check that the power is on.

IF THE DISPENSER DOESN’T DISPENSE
1.  The dispenser needs to be used several times upon 

first use.

2.  The sanitiser gel may congeal in cold temperatures. 

Use warm water (aproximately 60°c) to disperse the 

congealed sanitiser gel.

3.  Check that there is gel in the dispenser.

Figure 1

Figure 2

Figure 3

Automatic Soap Dispenser: User manual

Отзывы: