INSTRUCTIONS
SPECIFICATION
MODEL
AUTDISP
OUTER SIZE
L110*W100*H165MM
CAPACITY
700ml
DROP VOLUME
0.8-1ml
WEIGHT
480g
MATERIAL
ABS, AS
BATTERY
5X1.5V “AA”
TECHNICAL PARAMETERS
ELECTRICAL SOURCE VOLTAGE
DC6V
STATIC CURRENT
60UA
WORKING CURRENT
200MA
POWER
4W
EFFECT DISTANCE
0-10CM
Cover
Key
Container
LED lamp
Infrared sensor
window
Battery compartment
Pump
Power
on/off
SETUP
FEATURES
The sensor is at the base of the dispenser with effect
range of 0-10cm underneath the sensor.
Continually flashing LED light in standby mode
indicates battery replacment is necessary.
This product is not fully waterproof and should not
be placed in a continually damp environment.
The dispenser works both inside and outside
but should be kept out of direct sunlight as this
can affect the both the sanitiser gel and also the
function of the sensor.
INSTALLATION AND USE
1. Slide the dispenser into the mounting plate (figure 1).
2. Insert batteries into battery compartment with
polarity as indicated (alkaline batteries are
recommended).
3. Open the cover and pour the liquid into the
container (figure 2).
4. Put your hand 0-10cm under the sensor and allow
the dispenser to operate until the sanitiser gel
runs from the nozzle (figure 3). When using the
dispenser for the first time you may need to
activate the dispenser upto 15 times to enable
the sanitiser gel to work through the pump
before it will dispense.
5. Power On/Off button
First press will turn on giving a standard
dispense and LED light flashes once.
Second press will increase to a double
dispense and LED light flashes twice
Third press will turn the dispenser off
and LED light glows for one second
The two different settings can be used to give
the right amount of sanitiser gel, ensuring when
it is thicker in colder conditions an effective
dose is delivered everytime.
IF THE DISPENSER DOESN’T TURN ON
1. Check the batteries are inserted with polarity as
indicated in the battery compartment.
2. Check that the power is on.
IF THE DISPENSER DOESN’T DISPENSE
1. The dispenser needs to be used several times upon
first use.
2. The sanitiser gel may congeal in cold temperatures.
Use warm water (aproximately 60°c) to disperse the
congealed sanitiser gel.
3. Check that there is gel in the dispenser.
Figure 1
Figure 2
Figure 3
Automatic Soap Dispenser: User manual