Sans Digital MOBILESTOR MS4UT+(B) Скачать руководство пользователя страница 2

5) METAL FRAME

4) HDD HANDLE

3) RIGHT SIDE PANEL

1) FRONT PANEL

RAID Setup

Notes

Diagrams

2) REAR PANEL

RAID Config.

USB 3.0 Port
eSATA Port

1394a Port (MS4CT+)

Fan

Power

Connector

1394b Port

(MS4CT+)

1) Operating Environment: Temperature 0 - 50 Celsius / Humidity 0% - 
90%.

2) USB port of your PC must support power-off function so that the 
device would go to sleeping mode. Setting up motherboard's (power 
management) in S3 is strongly recommended. For more details, please 
refer to user guide of motherboard BIOS setting.

3) Smart fan is controlled by the built-in thermal sensor, and it comes 
with 2 modes (auto / manual) and 3 levels of speed:  
 

Level 1:  higher than 55°C 

2,500rpm - 3,500rpm

 

Level 2:  45°C - 54°C 

1,800rpm - 2,500rpm 

 

Level 3:  below 45°C 

1,200rpm - 1,800rpm

4) Press the power button to power on the device or press the button 
for 3 seconds to power off the device.

1) For RAID setup, press and HOLD the “MODE” button for 3 
seconds until the LED flashes. Press the button again to change the 
RAID mode. (The default setting is “RAID 5”)

2) After selecting the desired RAID mode, press and HOLD the 
confirmation button located behind a small cover on the back panel 
until the device powers off.

3) The selected RAID set will be ready to use. Please format the disk 
follwing the OS instructions.
    A) Please refer to manufacture website for a list of certified HDDs.
    B) Rebuild time varies depending on the HDD volume, about 1 hour 
    for 200GB. Once Rebuild is complete, the rebuild LED will turn off.

3

2

5

6

15

16

17

18

21

22

23

24

1

13

4

7

8

9

10

11

12

14

19

20

1) Blue - Power on
    Orange - Sleep
2) USB - In use / access
3) Power button - It needs to be pressed and held for 3 secs to power off. (This 
design prevents accidental power off.)
4) Mode - RAID mode button needs to be pressed and held for 3 secs to switch 
the device RAID mode. Confirmation button is located at on the back of the 
unit. (This design will prevent accidental execution of this function.)
5) Fan button - Controls auto & manual modes and fan speed from level 1 to 
level 3.
6) RAID 0 - Spanning mode / BIG.
7) RAID 0 - Striping mode.
8) RAID 1 - Mirroring mode.
9) RAID 3
10) RAID 5
11) RAID 10
12) Rebuild
13) eSATA - In use / access.
14) Firewire - In use / access. (MS4CT+ only)
15) Smart fan automatic mode.
16) Smart fan manual mode.
17) Fan speed - Level 1
18) Fan speed - Level 2
19) Fan speed - Level 3
20) HDD error - When any of HDD 1 - HDD4 has error, HDD error is on.
21 - 24) HDD1 / HDD2 / HDD3 / HDD4
      Blue - Active 

Purple - Access 

Red - Rebuild

NOTE: When using RAID function, 

HDDs with the same brand, model and 

capacity is strongly recommended.

Отзывы: