17
4. Turn on the power than release the SETUP BUTTON to complete mode setting.
3.5.6
R1 MODE
The R1 MODE storage policy requires 2 drives to implement.
1. Turn off the power.
2. Set the MODE SWITCH position to R1/R10.
3. Press and hold the recessed SETUP BUTTON.
4. Turn on the power than release the SETUP BUTTON to complete mode setting.
3.5.7
R1 MODE WITH HOT SPARE
1. Turn off the power.
2. Insert 3 drives in order from the top to the bottom.
3. Set the MODE SWITCH position to R1/R10.
4. Press and hold the recessed SETUP BUTTON.
5. Turn on the power than release the SETUP BUTTON to complete mode setting.
3.5.8
R10 MODE
The R10 MODE storage policy requires 4 drives to implement.
1. Turn off the power.
2. Set the MODE SWITCH position to R1/R10.
3. Press and hold the recessed SETUP BUTTON.
4. Turn on the power than release the SETUP BUTTON to complete mode setting.
3.5.9
R3 MODE
The R3 MODE storage policy requires a minimum of 3 drives to implement.
1. Turn off the power.
2. Set the MODE SWITCH position to R3.