background image

Chapter 1. Introduction     

 

 

 

 

 

U

U

Un

n

nd

d

de

e

er

r

rs

s

st

t

ta

a

an

n

nd

d

di

i

in

n

ng

g

 

 t

t

th

h

he

e

 

 A

A

Ac

c

cc

c

cu

u

uS

S

ST

T

TO

O

OR

R

 

 R

R

RA

A

AI

I

ID

D

 

 s

s

su

u

ub

b

bs

s

sy

y

ys

s

st

t

te

e

em

m

 

 

Front Panel Overview 

LCD Module 

 

Function keys. ( ENT, ESC, Scroll up, Scroll Down ) 

                                                              

Keys 

Descriptions  

Up Arrow 

To scroll upward through the menu items 

Down Arrow 

To scroll downward through the menu items 

(ENT )  Enter 

To confirm a selected item 

(ESC)   ESC 

To  exit  a  sub-menu  and  return  to  previous 

menu. 

       

 

 

 

 

Содержание AccuSTOR AS424X12

Страница 1: ......

Страница 2: ...n either express or implied and provide it as it This includes but is not limited to any implied warranties of merchantability and fitness for a particular purpose The information in this document is subject to change without notice We assume no responsibility for any errors that may appear in this document The manufacturer shall not be liable for any damage or for the loss of information resultin...

Страница 3: ...e to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antennas Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circlet different from that to which the receiver is connecte...

Страница 4: ...e upgrades For the detail about how to configure your subsystem please refer to the Software Operation manual S S Sy y ym m mb b bo o ol l ls s s i i in n n T T Te e ex x xt t t These symbols may be found in the text of this guide They have the following meanings Caution This icons indicates that failure to follow directions could result in personal injury damage to your equipment or loss of infor...

Страница 5: ...ear Panel Overview 8 Chapter 2 INSTALLATION 12 Unpacking checking the Equipment 12 What else you need 14 ESD Precaution 14 Installing hard disks 14 Install The AccuSTOR JBOD subsystem in a Rack 16 System Connection 18 Connection to the RAID System Basic 19 Connection to the RAID System with more 19 SAS JBODs 19 Turning on for the first time 20 Turning off 21 Chapter 3 TROUBLE SHOOTING 22 Replace t...

Страница 6: ...ppendix C 30 Command Line Interface CLI 30 Create a CLI connection 30 Locations of RS 232C Port 30 Establishing the Connection for the Console Terminal RS 232 Port 30 CLI Command Set 37 HELP Command 37 PASS Command 38 LO Command 38 LINK Command 39 DHPM Command Same as EDFB 42 TH Command 45 GROUP Command 48 SYS Command 50 BU Command 51 FAN Command 52 SPIN Command 54 ...

Страница 7: ...on Guide vii ST Command 55 LSD Command 56 SHOWLOGS Command 58 FDL Command 59 Counters Reset Command 61 Sasaddr Command 62 Appendix D 63 LCD Configuration Manager 63 Appendix E Specifications 67 Specifications 67 ...

Страница 8: ......

Страница 9: ...Numbers AS424X12 R SAS miniSAS HD 24 bays 1 or 2 AS316X12 R SAS miniSAS HD 16 bays 1 or 2 AS212X12 R SAS miniSAS HD 12 bays 1 or 2 AS224X12 R SAS miniSAS HD 24 bays 1 or 2 F F Fe e ea a at t tu u ur r re e es s s The 12Gb JBOD system is designed to meet today s large volume and excellent performance storage requirements in rapidly changing business environment It provides a maximum data protection...

Страница 10: ...d backplanes The expander buffers 12Gb s data and then transfers it out to the host at 12Gb s speeds in order to match the bandwidth between faster hosts and slower SAS or SATA devices The 12Gb JBOD systems contains an embedded expander manager that can access via in band SES 2 over SMP protocol and out of band RS 232 port An out of band serial port is available for managing the configuration and ...

Страница 11: ...R RA A AI I ID D D s s su u ub b bs s sy y ys s st t te e em m m Front Panel Overview LCD Module Function keys ENT ESC Scroll up Scroll Down Keys Descriptions Up Arrow To scroll upward through the menu items Down Arrow To scroll downward through the menu items ENT Enter To confirm a selected item ESC ESC To exit a sub menu and return to previous menu ...

Страница 12: ...il Indicator LED never light up LED light up as Red Data Access Indicator Blink blue during host computer accessing the RAID subsystem LED never flickers Driver Bay numbering convention The enclosure bay numbering convention is shown in following figure A bay is designed to house a single 3 5 inch hard disk drive or a 2 5 hard disk in his carrier module AS424X12 R AS316X12 R 1 2 3 4 5 6 7 8 9 10 1...

Страница 13: ...Chapter 1 Introduction 5 AS212X12 R AS224X12 R 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ...

Страница 14: ...Installation Guide 6 Drive Bay for 3 5 Series Drive Bay for 2 5 Series Handle Release Button Key Lock LED Indicator Red HDD Error LED Indicator Blue HDD Power on Flash Accessing Lock Unlock Lock Unlock ...

Страница 15: ...Chapter 1 Introduction 7 Handle Latch Key Lock LED Indicator Blue HDD Power on Flash Accessing LED Indicator Red HDD Error ...

Страница 16: ... 8 Rear Panel Overview AS424X12 R AS316X12 R 1 Expander Box 1 2 Expander Box 2 3 SAS CH 0 LED Indicator LED Colors Indicate 9 10 11 2 4 3 5 7 6 1 8 12 13 14 15 16 17 18 19 20 9 10 11 1 2 8 12 13 14 15 16 4 3 5 7 6 17 18 ...

Страница 17: ...Expand Port 0 LED Indicator LED Colors Indicate SAS Green Link Blue Blink Access 6 Console Terminal Port 7 Reserved 8 Power Switch 9 FAN failure indicator Rear Front 10 FAN Module 1 11 FAN Module 1 latch 12 FAN failure indicator Rear Front 13 FAN Module 2 14 FAN Module 2 latch 15 AC inlet 1 Latch 16 Power Module 1 17 AC inlet 2 Latch 18 Power Module 2 ...

Страница 18: ...olors Indicate SAS Green Link Blue Blink Access 4 SAS Expand Port 1 LED Indicator LED Colors Indicate SAS Green Link Blue Blink Access 5 SAS Expand Port 0 LED Indicator LED Colors Indicate SAS Green Link Blue Blink Access 6 Console Terminal Port 7 Reserved 8 Power Switch 9 10 13 14 8 11 12 15 16 4 3 5 7 6 1 2 ...

Страница 19: ...pter 1 Introduction 11 9 FAN failure indicator 1 Rear Front 10 FAN Module 1 11 FAN failure indicator 2 Rear Front 12 FAN Module 2 13 AC inlet 1 Latch 14 Power Module 1 15 AC inlet 2 Latch 16 Power Module 2 ...

Страница 20: ...er Altogether you should find following items in the package AccuSTOR Series 12Gb SAS to SAS SATA JBOD Subsystem JBOD subsystem x1 CD ROM x 1 Includes Hardware Installation Guide Serial cable x1 Power Cord x 2 AS316X12 R and AS212X12 R Power Cord x 3 AS424X12 R miniSAS HD cable SFF 8644 x 1 Drive Bay AS212X12 R x 12 AS316X12 R x 16 AS424X12 R x 24 Key for Drive Bay x 4 Slide Kit Rails for Rack Mou...

Страница 21: ...Chapter 2 Installation 13 Power Cord x 2 AS224X12 R miniSAS HD cable SFF 8644 x 1 Drive Bay x 24 Key for Drive Bay x 4 Slide Kit Rails for Rack Mounting screws for 2 5 disks bag 1 ...

Страница 22: ...nd observe all conventional ESD precaution when handle AccuSTOR JBOD s modules and components Avoid contact with backplane components and module connectors I I In n ns s st t ta a al l ll l li i in n ng g g h h ha a ar r rd d d d d di i is s sk k ks s s The AccuSTOR JBOD series includes 12 16 24 hot swappable drive bays The following sections describe how to install disks into AccuSTOR JBOD subsys...

Страница 23: ...ose the handle to engage the drive bay into the slot Note The hard drives in a JBOD should match in size and speed All drives in any array should be identical models with the same firmware versions Caution Only use the screws offered with AccuSTOR RAID subsystem Longer screws might cause the drive damage All the drive bays with or without hard drive must be placed in the AccuSTOR subsystem AccuSTO...

Страница 24: ...ystem is designed for installation into a industry standard 19 inch rackmount cabinet Following the use of this section for installing the AccuSTOR subsystem into a Rack Install the Slide Rails 1 Combine Left slide rail and rear slide rail 2 Measure the depth of the rack enclosure then fasten 4 of P4 8M screws into M4 Locking nuts to fix the length 3 Use T5 8M screws and PW14 washer to install the...

Страница 25: ...ck 1 Lift the subsystem enclosure and slide it slowly and gently along the slide rail into the rack as Figure 2 Figure 2 2 Fasten two M5 screws through the chassis ears in the front side of the chassis to secure the AccuSTOR subsystem in the rack as Figure 3 Figure 3 ...

Страница 26: ...pose Serial Cable Console ANSI Terminal or PC with Terminal emulator Configuration Utility MiniSAS HD Cable SAS CH0 SAS HBA of Host computer AccuSTOR SAS RAID subsystem Host interface between JBOD and Host computer Power Cord Power inlet A C power outlet A C power input MiniSAS HD Cable SAS Exp AccuSTOR JBOD Connect to SAS Expander Note Make sure that all the devices are powered off before connect...

Страница 27: ...D D D S S Sy y ys s st t te e em m m w w wi i it t th h h m m mo o or r re e e S S SA A AS S S J J JB B BO O OD D Ds s s It supports up to four tiers and 256 drives One RAID Set supports up to 32 HDDs One SAS RAID subsystem supports up to 128 Volumes One SAS RAID subsystem supports up to 256 SAS devices 16Gb Fibre RAID 12Gb SAS JBOD 12Gb SAS JBOD 12Gb SAS JBOD 12Gb SAS JBOD 12Gb SAS JBOD 16Gb Fibr...

Страница 28: ...and capacity in this RAID subsystem 3 Please do not install SAS and SATA hard drives at the same time as these hard drives spin at different speed and may lead to compatible issues or performance decline 4 RAID members need to be included at the same enclosure that means you need to create array in the same enclosure RAID members across two or more enclosures would get some risks for example if mi...

Страница 29: ...tion 21 T T Tu u ur r rn n ni i in n ng g g o o of f ff f f When turning off RAID system 12Gb s JBOD system users are advised to first shut down the server then power off RAID SYSTEM finally power off 12Gb s JBOD SYSTEM ...

Страница 30: ...replace it as soon as possible R R Re e ep p pl l la a ac c ce e e t t th h he e e E E Ex x xp p pa a an n nd d de e er r r b b bo o ox x x Read the replacing notices earlier in this chapter before proceeding with replacement This section provides instructions for the removal and installation of the Expander box components indicated in the figure below This section is for the reference of engineer...

Страница 31: ...stalling the Expander box into JBOD subsystem Reverse the procedure of removing the controller to install the controller into AccuSTOR JBOD Subsystem H H Ho o ot t t S S Sw w wa a ap p pp p pi i in n ng g g t t to o o r r re e ep p pl l la a ac c ce e e t t th h he e e F F Fa a an n n M M Mo o od d du u ul l le e e This section provides instructions for the removal and installation of the Fan Modu...

Страница 32: ...on the rear of Fan module Check which LED lights to yellow 2 Remove the Fan modules by anti clock wise to release the thumb screw then slide it back and lifting off 3 Release the screw to remove the defect fan 4 Insert the spare Fan and fasten the screw Removing the Fan Module from AS212X12 R AS224X12 R JBOD Remove the Fan modules by slide the release button left and pull the module out of system ...

Страница 33: ...le e e This section provides instructions for the removal and installation of the Power Module indicated in the figure below Removing the Power Module Unscrew the thumb fastener then push right the release button slide it back and lifting off Installing the Power module into AccuSTOR Insert a Power module then fasten the screw The Power indicator will turn bright Green to indicate it has powered o...

Страница 34: ...Installation Guide 26 A Ap pp pe en nd di ix x A A C Co on nn ne ec ct to or rs s RJ 11 miniSAS HD SFF 8644 Pin Signal Pin Signal 1 NC 6 NC 2 GND 3 RX 4 TX 5 CTS ...

Страница 35: ...4 Rx 1 A5 Sideband 7 A1 Sideband 3 B1 Sideband 4 C1 Sideband 5 D1 Rx 2 B7 Rx 2 B8 Rx 3 A7 Rx 3 A8 Tx 0 D4 Tx 0 D5 Tx 1 C4 Tx 1 C5 Sideband 0 A2 Sideband 1 B2 Sideband 2 C2 Sideband 6 D2 Tx 2 D7 Tx 2 D8 Tx 3 C7 Tx 3 C8 SIGNAL GROUND A3 A6 A9 B3 B6 B9 C3 C6 C9 D3 D6 D9 ...

Страница 36: ...a CLI connection then follow the steps as bellowing to update the firmware of JBOD 1 First type fdl code under CLI prompt 2 Then under hyper terminal click file at top to pull down the menu Choose Xmodem and select the firmware file in the directory then press send to attach file If file is receiving within the timeout limit 60sec then firmware update will proceed If a timeout message appear pleas...

Страница 37: ...6 Perform a cold start after the firmware updating is completed 7 After the firmware updating is completed repeat steps 1 6 to update the Data file but change the CLI command as following CLI fdl mfgb Then use file mfgdata rom to update the Datafile 8 After both files are updated restart the expander 9 After restart the expander repeat steps 1 6 to update the Code file again 10 After both files ar...

Страница 38: ...ion for the Console Terminal RS 232 Port The CLI function can be done by using an ANSI VT 100 compatible terminal emulation program You must complete the appropriate installation procedure before proceeding with the CLI function Whichever terminal emulation program is used must support the 1K XMODEM file transfer protocol The Console Terminal RS 232 port on the JBOD system I O shield can be used i...

Страница 39: ...ription 1 N C 6 NC 2 GND 3 RX 4 TX 5 CTS By connecting a VT100 compatible terminal or a PC operating in an equivalent terminal emulation mode all RAID subsystem monitoring configuration and administration functions can be exercised from the VT100 terminal There are a wide variety of Terminal Emulation packages but for the most part they should be very similar The following setup procedure is an ex...

Страница 40: ...Installation Guide 32 Step 2 Open HYPERTRM EXE ...

Страница 41: ...Appendix C Command Line Interface 33 Step 3 Enter a name for your Terminal Click OK Step 4 Select an appropriate connecting port in your Terminal Click OK ...

Страница 42: ...nstallation Guide 34 Step 5 Configure the port parameter settings Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None Click OK Step 6 Open the File menu and then open Properties ...

Страница 43: ...Appendix C Command Line Interface 35 Step 7 Open the Settings Tab ...

Страница 44: ...de 36 Step 8 Open the Settings Tab Function arrow and ctrl keys act as Terminal Keys Backspace key sends Crtl H Emulation VT100 Telnet terminal VT100 Back scroll buffer lines 500 Click OK Now the VT100 is ready to use ...

Страница 45: ... brief descriptions of the help sub commands You can use the CLI help to get detail information about the CLI commands summary Syntax CLI help Enter Example CLI help Pass Set Password Lo Logout CLI Shell Link Link Rate Control dhpm edfb Bandwidth Optimizer th Temperature Control group Set the PHY Group sys System Information bu Alarm Control fan Fan Speed Control spin Drive SpinUp Control st Store...

Страница 46: ...e SAS JBOD setting by providing the correct password The password can accept max 8 chars and min 4 chars The manufacture default password is 0000 Syntax CLI pass Enter Example CLI pass Old Password New Password Verify New Password Password Changed But Not Save Permanently Note use CLI command st to keep permanently LO Command To exit the selected SAS JBOD CLI shell use the lo command Syntax CLI lo...

Страница 47: ...ink c 0 1 2 3 High Low Index c 0 1 2 3 External Cable Index The cable c0 c1 or c2 is view from right to left or start from top to bottom High Rate Low Rate 11 12G 10 6G 9 3G PS Pls Save Config Reboot To Take Effect CLI st Example CLI link c0 c1 10 9 set cable0 and cable1 link speed range max 10 6G min 9 3G CLI st CLI Reboot to take effect 2 Set all slots with same link speed rate Syntax CLI link I...

Страница 48: ... CLI link Index Max Min Enter Index Slot Index High Rate Low Rate 11 12G 10 6G 9 3G PS Pls Save Config Reboot To Take Effect CLI st Example CLI link ArrayDevice Element 0x17 NAME PHY ORG NLR MAX MIN TYPE ADDRESS SLOT 01 13 6G 6G 11 9 SATA 5001B469 189AE00D SLOT 02 12 6G 6G 11 9 SAS 5011B469 189AE00C SLOT 03 14 6G 6G 11 9 SATA 5011B469 189AE00E SLOT 04 15 6G 6G 11 9 SATA 5011B469 189AE00F ...

Страница 49: ...SLOT 09 5 6G 6G 11 9 SATA 5011B469 189AE005 SLOT 10 4 6G 6G 11 9 SATA 5011B469 189AE004 SLOT 11 6 3G 3G 11 9 SAS 500000E0 168F8E92 SLOT 12 7 3G 3G 11 9 SAS 500000E0 168F8E99 Set the slot 0x6 max speed to 3 0G CLI link 6 9 9 CLI st CLI Reboot to take effect CLI link ArrayDevice Element 0x17 NAME PHY ORG NLR MAX MIN TYPE ADDRESS SLOT 01 13 6G 6G 11 9 SATA 5001B469 189AE00D SLOT 02 12 6G 6G 11 9 SAS ...

Страница 50: ...1 9 SATA 5011B469 189AE004 SLOT 11 6 3G 3G 11 9 SAS 500000E0 168F8E92 SLOT 12 7 3G 3G 11 9 SAS 500000E0 168F8E99 DHPM Command Same as EDFB Use for 3G 6G SAS SATA drive speed up as 12G drive performance DataBolt Bandwidth Optimizer is designed to help facilitate the industry transition to 12Gb s SAS enabled systems by allowing users to take advantage of 12Gb s speeds while utilizing existing 6Gb s ...

Страница 51: ...YPE ADDRESS SLOT 01 13 6G 6G 11 9 SATA 5001B469 189AE00D SLOT 02 12 6G 6G 11 9 SAS 5011B469 189AE00C SLOT 03 14 6G 6G 11 9 SATA 5011B469 189AE00E SLOT 04 15 6G 6G 11 9 SATA 5011B469 189AE00F SLOT 05 9 6G 6G 11 9 SATA 5011B469 189AE009 SLOT 06 8 6G 6G 11 9 SATA 5011B469 189AE008 SLOT 07 10 6G 6G 11 9 SATA 5011B469 189AE00A SLOT 08 11 6G 6G 11 9 SATA 5011B469 189AE00B SLOT 09 5 6G 6G 11 9 SATA 5011B...

Страница 52: ...link ArrayDevice Element 0x17 NAME PHY ORG NLR MAX MIN TYPE ADDRESS SLOT 01 13 6G 6G 11 9 SATA 5001B469 189AE00D SLOT 02 12 6G 12G 11 9 SAS 5011B469 189AE00C SLOT 03 14 6G 6G 11 9 SATA 5011B469 189AE00E SLOT 04 15 6G 6G 11 9 SATA 5011B469 189AE00F SLOT 05 9 6G 6G 11 9 SATA 5011B469 189AE009 SLOT 06 8 6G 6G 11 9 SATA 5011B469 189AE008 SLOT 07 10 6G 6G 11 9 SATA 5011B469 189AE00A SLOT 08 11 6G 6G 11...

Страница 53: ...000E0 168F8E99 CLI dhpm on set all drives on CLI st Reset or PowerCycle TH Command The th command allows you to set the operate device temperature warning limit Typical parameters include High Warn and Low Warn are warning temperature in Celsius Syntax CLI th Index High Warn Low Warn Example CLI th Temperature Element 0x04 NAME ID CT C HTW LTW OTWarn ENC Temp 01 30 60 5 No Chip Temp 02 64 90 5 No ...

Страница 54: ... 06 31 60 5 No Slot05 Temp 07 36 60 5 No Slot06 Temp 08 32 60 5 No Slot07 Temp 09 32 60 5 No Slot08 Temp 10 35 60 5 No Slot09 Temp 11 34 60 5 No Slot10 Temp 12 32 60 5 No Slot11 Temp 13 32 60 5 No Slot12 Temp 14 32 60 5 No CLI th 2 79 0 Temperature Element 0x04 NAME ID CT C HTW LTW OTWarn ENC Temp 01 30 60 5 No ...

Страница 55: ...2 60 5 No Slot08 Temp 10 35 60 5 No Slot09 Temp 11 34 60 5 No Slot10 Temp 12 32 60 5 No Slot11 Temp 13 32 60 5 No Slot12 Temp 14 33 60 5 No CLI st CLI Reboot to take effect CLI th Temperature Element 0x04 NAME ID CT C HTW LTW OTWarn ENC Temp 01 30 60 5 No Chip Temp 02 64 79 0 No Slot01 Temp 03 31 60 5 No Slot02 Temp 04 32 60 5 No Slot03 Temp 05 30 60 5 No Slot04 Temp 06 31 60 5 No Slot05 Temp 07 3...

Страница 56: ...dex D End Index D gr off t10 off dev use drive slot index GroupNo groupno start from 1 max 8 groups ci cj ck external cable connector i j k is the index which range from 0 to 3 According to view from connector side index start from right to left or top to bottom The cable c0 c1 or c2 is view from right to left or start from top to bottom Start Index Start slot index of zone range 1 max drive End I...

Страница 57: ...x0000000FFFFFFFFF Set the cable1 and cable2 and slot 7 to slot 16 as group 2 CLI gr dev 2 c1 c2 7 16 New PHY Group Mode T10 Group 1 C0 Slot 1 2 3 4 5 6 Value 0x00000000000FFC00 Group 2 C1 C2 Slot 7 8 9 10 11 12 13 14 15 16 Value 0x000000000FF003FF Current PHY Group Mode T10 Group 1 C0 C1 C2 Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Value 0x0000000FFFFFFFFF CLI st Power Cycle to reboot CLI gr Cur...

Страница 58: ...ue 0x00000000000FFC00 Group 2 C1 C2 Slot 7 8 9 10 11 12 13 14 15 16 Value 0x000000000FF003FF SYS Command The sys command is used to view the expander s information Typical information includes vendor model name serial unit number expander port number product revision chip name chip revision customer code manufacture data revision and work time Syntax CLI sys Enter Example CLI sys Hardware Revision...

Страница 59: ...t Boot Yes Image Address 0x10000000 Firmware Copy 1 Revision 100 BD 01 0A 01 06 14 Firmware Family 0 OemFamily 0 Fast Boot Yes Image Address 0x10100000 Firmware Copy 2 Active Revision 100 BD 01 0A 01 06 14 Firmware Family 0 OemFamily 0 Fast Boot Yes Image Address 0x10200000 HAL Revision 0 1 0 0 SES Revision 0 1 0 0 SCE Revision 0 1 0 0 BU Command The BU command allows you to control the buzzer att...

Страница 60: ...nt CLI BU MUTE When expander alarm with buzzer you can disable it completely by command bu 0 0 If you would like to enable beeper the command for default settings will be bu 2 3 FAN Command The fan command allows you to set the operate fan speed Typical parameters include LowestSpeed and WarningSpeed are fan speed in speed code from level 1 to 7 The LowestSpeed is the speed code that fan operate i...

Страница 61: ...OK Fan 03 2 3650 OK Fan 04 2 4050 OK Current FAN Speed Attribute Lowest SpeedCode 2 Warning SpeedCode 5 CLI fan 3 7 New FAN Speed Attribute Lowest SpeedCode 3 Warning SpeedCode 7 Current FAN Speed Attribute Lowest SpeedCode 2 Warning SpeedCode 5 CLI st CLI Reboot to take effect CLI fan Cooling Element 0x03 SPEED NAME CODE RPM STATUS ...

Страница 62: ...s normal SPIN Command The spin command defines the mode of staggering SATA drive spin up function connected on the expander box This command gives expander box the ability to spin up the disk drives sequentially or in groups allowing the drives to come ready at the optimum time without straining the system power supply Staggering drive spin up in a multiple drive environment also avoids the extra ...

Страница 63: ... Number 1 Delay 1024 ms ST Command The st command stores system configurations in flash Since all the revised parameter setting is temporarily stored in the working RAM the ST command saves those parameters permanently in flash ROM 1 Store temporarily configurations in flash Syntax CLI st Example CLI st CLI 2 Store factory default configurations in flash Syntax CLI st default Example ...

Страница 64: ...ice status Syntax CLI lsd hdd temp volt pwr con Show SES elements information ArrayDevice Element 0x17 NAME PHY NLR MAX MIN TYPE ADDRESS SLOT 01 0 3 0G 10 9 SAS 5000C500 0D2002D1 SLOT 02 1 10 9 SLOT 03 2 10 9 SLOT 04 3 1 5G 10 9 SATA 5001B469 84965C03 SLOT 05 4 10 9 SLOT 06 5 10 9 SLOT 07 6 6 0G 10 9 SAS 5000C500 17C8FD25 SLOT 08 7 10 9 SLOT 09 8 10 9 SLOT 10 9 10 9 SLOT 11 10 10 9 SLOT 12 11 10 9...

Страница 65: ...1 6 0G 02 Connected Connector01 22 6 0G 02 Connected Connector01 23 6 0G 02 Connected Connector02 24 02 Connector02 25 02 Connector02 26 02 Connector02 27 02 Cooling Element 0x03 SPEED NAME CODE RPM STATUS Fan 01 5 2100 OK Fan 02 5 2200 OK Fan 03 Not Installed Fan 04 Not Installed Temperature Element 0x04 NAME ID CT C HTW LTW OTWarn ENC Temp 01 32 60 5 No Chip Temp 02 42 85 0 No ...

Страница 66: ...K AudibleAlarm Element 0x06 NAME STATUS ALMSTATE Audible Alarm Normal 0 CLI SHOWLOGS Command The showlogs command allows you to display system event notifications that have been generated event by the SAS expander box Syntax CLI showlogs DisplayMode hex detail default Example CLI showlogs 00000000 00000000 PLATFORM Firmware initialization started Day00000 00 00 00 ENCLOSURE Fan 01 Failed ...

Страница 67: ...edures is used to update firmware through the RS 232 1 Open any UART communication tools like HypeTerminal 115200 n 8 1 2 Press any key on HyperTerminal window the window will show CLI prompt 3 Type help will show help screen 4 One command to update firmware Step as follow 5 Issue download update command under CLI CLI fdl code Please Use XModem Protocol for File Transmission Use Q or q to quit Dow...

Страница 68: ... the transfered data is updated Cold start expander Power cycle again to take effect The following firmware and data are available in the following filename format 1 FW file CODE sas3xfwYYMMDD fw 2 Data file MFGB mfg12gYYMMDD rom Update SAS expander firmware CLI fdl code Use HyperTerminal or TeraTerm utility with Xmodem mode to transfer sas3xfwYYMMDD fw If transfer OK the transfer data is updated ...

Страница 69: ...4 0x00000000 0x00000000 0x00000000 0x00000000 Phy 05 0x00000000 0x00000000 0x00000000 0x00000000 Phy 06 0x00000000 0x00000000 0x00000000 0x00000000 Phy 07 0x00000000 0x00000000 0x00000000 0x00000000 Phy 08 0x00000000 0x00000000 0x00000000 0x00000000 Phy 09 0x00000000 0x00000000 0x00000000 0x00000000 Phy 10 0x00000000 0x00000000 0x00000000 0x00000000 Phy 11 0x00000000 0x00000000 0x00000000 0x000000...

Страница 70: ...5 0x00000000 0x00000000 0x00000000 0x00000000 Phy 26 0x00000000 0x00000000 0x00000000 0x00000000 Phy 27 0x00000000 0x00000000 0x00000000 0x00000000 Link Layer Event Counters Phy Event Counter Not Configured Generic Broadcast Counter Broadcast Counter Not Configured Generic Broadcast Counter Broadcast Counter Not Configured Sasaddr Command CLI sasaddr Expander New SAS Address 0x5001B4690400083F Exp...

Страница 71: ...through this interface Navigation Map of the LCD The password option allows user to set or clear the password protection feature Once the password has been set the user can only monitor and configure the unit by providing the correct password The password is used to protect the unit from unauthorized entry The unit will check the password only when entering the main menu from the initial screen Th...

Страница 72: ...Password HDD01 _Set Max Rate 12G _Set Max Rate 3G HDD02 HDD03 WrapsAround LCM Functions Set Alarm Enter Password _Set Alarm Beep Mute Beep _Set Alarm Beep Sound 2 _Set Alarm Beep Sound 3 Set Password Set New PWD Save Config Save Config Exit No Sel Yes System Reset Reset System Exit No Sel Yes ...

Страница 73: ...t key to go back to the main selection Set Link Set HDD devices maximun minimun link speed rate The value could be 12G 6G or 3G each of HDD devices link speed will have the sub items are shown as below _Set Max Rate 12G _Set Min Rate 3G Set Alarm Set enclosure buzzer warning critical error beep style or mute the current beep The value could be Sound 1 Sound 2 Sound 3 Sound 4 and Sound Disabled Sou...

Страница 74: ...66 Save Config Save all the updated option value into non volatile memory area System Reset Reboot the system ...

Страница 75: ... module with PFC function Load sharing type and cable less design with Redundancy Three Power inlet 500 500 watts Redundancy 80 Plus energy Efficient power system two 500 watts module with PFC function Load sharing type and cable less design with Redundancy Dual Power inlet Electrical AC Voltage 100 240 VAC Ac Frequency 47 63Hz Temperature Operating Temperature 5 to 35 degree C Non Operating Tempe...

Страница 76: ...o 500 watts module with PFC function Load sharing type and cable less design with Redundancy Dual Power inlet Electrical AC Voltage 100 240 VAC Ac Frequency 47 63Hz Temperature Operating Temperature 5 to 35 degree C Non Operating Temperature 40 to 60 degree C Relative Humidity 20 to 80 non condensing Dimensions 449mm W 468mm D 2U ...

Отзывы: