CAFE RACER
04-2017
Manual for technical
50 / 56-EN
EN
8.17 Boiler temperature
Chec that the service boiler temperature is set to
124°C / 255°F in this section.
- Press the button “
” to go to the next section.
8.18 unit 1-2-3 temperature offset
If there are discrepancies between the set temper
-
ature and the actual temperature, they can be cor
-
rected by increasing or decreasing the temperature
of the unit.
- Press the button “
” or “
” to set the value.
- Press the button “
” to go to the next section.
8.19 Inactivity time
If the machine is installed in an outdoor ios , the
temperature is low and the machine is inactive for a
few minutes, the unit temperature may drop 0.5 °C
or 1°C.
-
ou can set an inactivity time beyond which the
machine automatically increases the unit tempera-
ture to a value set in the next screen REST TEMP.
OFS .
- Press the button “
” or “
” to set the values.
- Press the button “
” to go to the next section.
In this section
, you can set the degrees of unit tem
-
perature increase in order to compensate for
inactivity or a cold climate.
- Normally this function is not used, so set the value
to 0 in both screens to disable the function.
- Press the button “
” to go to the next section.