Specifications
Items
Applications
Model
Probe built-in coating thickness meter SAMAC-F
Measuring method
Electromagnetic induction type
Display method
Graphic LCD (data/message), Backlight
Measuring range
Fe substrate: 0~2.5mm
Calibration (CAL)
2-point calibration
Zero: metal substrate calibration
Calibration standard: metal substrate and standard thickness calibration
Resolutions
1
μ
m unit
:
0~999
μ
m
0.01mm unit : 1.00~2.50mm
by switching
0.1
μ
m unit
:
0~400
μ
m
0.5
μ
m unit
:
400
μ
m~500
μ
m
Accuracies
(to flat, smooth face)
0~100
μ
m: ±1
μ
m or ±2% of reading
101
μ
m~2.5mm: ±2%
Probe (built-in)
One point constant pressure contact type with V cross-cut groove
Measuring part
φ
28mm (probe partφ10mm)
Additional functions
①
Switching to Measuring mode (hold/non-interrupt)
②
Auto Power Off (3 min.), releasing and reactivating
③
Backlight
④
Switching of display resolutions
Keys
ON/OFF , ZERO , ▲ , ▼ , CAL/DELETE
Power source
3V DC Dry Battery (LR03×2), Continuous operation hours: 25 hours
Operating temperature
0 ~ 40 ℃ (Non-condensing)
Accessories
Thickness standards, Zero plate for testing (Fe), Carrying case for Thickness
standards, Carrying case for main unit, Dry batteries, Hand strap cord
Dimensions
63(W) × 84(H) × 30(D)mm
Weight
About 125g (including dry batteries)
April, 2015