background image

7

SANKEN ELECTRIC CO., LTD.

28103.33

Quasi-Resonant Topology 

Primary Switching Regulators

STR-W6756

Because reliability can be affected adversely by improper 
storage environments and handling methods, please observe 
the following cautions.

Cautions for Storage

•  Ensure that storage conditions comply with the standard 

temperature (5°C to 35°C) and the standard relative 
humidity (around 40% to 75%); avoid storage locations 
that experience extreme changes in temperature or 
humidity.

•  Avoid locations where dust or harmful gases are present 

and avoid direct sunlight.

•  Reinspect for rust on leads and solderability of the 

products that have been stored for a long time.

Cautions for Testing and Handling

   When tests are carried out during inspection testing and 

other standard test periods, protect the products from 
power surges from the testing device, shorts between 
the product pins, and wrong connections. Ensure all test 
parameters are within the ratings specified by Sanken for 
the products.

Remarks About Using Silicone Grease with a Heatsink

•  When silicone grease is used in mounting the products on 

a heatsink, it shall be applied evenly and thinly. If more 
silicone grease than required is applied, it may produce 
excess stress.

•  Volatile-type silicone greases may crack after long periods 

of time, resulting in reduced heat radiation effect. Silicone 
greases with low consistency (hard grease) may cause 
cracks in the mold resin when screwing the products to a 
heatsink.

 

Our recommended silicone greases for heat radiation 
purposes, which will not cause any adverse effect on the 
product life, are indicated below:

Type

Suppliers

G746

Shin-Etsu Chemical Co., Ltd.

YG6260

Momentive Performance Materials Inc.

SC102

Dow Corning Toray Co., Ltd.

Cautions for Mounting to a Heatsink

•  When the flatness around the screw hole is insufficient, such 

as when mounting the products to a heatsink that has an 
extruded (burred) screw hole, the products can be damaged, 
even with a lower than recommended screw torque. For 
mounting the products, the mounting surface flatness should 
be 0.05 mm or less. 

•  Please select suitable screws for the product shape. Do not 

use a flat-head machine screw because of the stress to the 
products. Self-tapping screws are not recommended. When 
using self-tapping screws, the screw may enter the hole 
diagonally, not vertically, depending on the conditions of hole 
before threading or the work situation. That may stress the 
products and may cause failures. 

•  Recommended screw torque: 0.588 to 0.785 N

m (6 to 8 

kgf

cm).

•  For tightening screws, if a tightening tool (such as a driver) 

hits the products, the package may crack, and internal 
stress fractures may occur, which shorten the lifetime of 
the electrical elements and can cause catastrophic failure. 
Tightening with an air driver makes a substantial impact. 
In addition, a screw torque higher than the set torque can 
be applied and the package may be damaged. Therefore, an 
electric driver is recommended.

 

When the package is tightened at two or more places, first 
pre-tighten with a lower torque at all places, then tighten 
with the specified torque. When using a power driver, torque 
control is mandatory.

Soldering

•  When soldering the products, please be sure to minimize 

the working time, within the following limits:

 

  260±5°C     10±1 s      (Flow, 2 times)

 

  380±10°C    3.5±0.5 s (Soldering iron, 1 time)

•  Soldering should be at a distance of at least 2.0 mm from 

the body of the products.

Electrostatic Discharge

•  When handling the products, the operator must be 

grounded. Grounded wrist straps worn should have at 
least 1 M

Ω

 of resistance from the operator to ground to 

prevent shock hazard, and it should be placed near the 
operator.

•  Workbenches where the products are handled should be 

grounded and be provided with conductive table and floor 
mats.

•  When using measuring equipment such as a curve tracer, 

the equipment should be grounded.

•  When soldering the products, the head of soldering irons 

or the solder bath must be grounded in order to prevent 
leak voltages generated by them from being applied to the 
products.

•  The products should always be stored and transported in 

Sanken shipping containers or conductive containers, or 
be wrapped in aluminum foil.

Содержание STR-W6756

Страница 1: ...ncreaseofoperatingfrequencyatlightoutputload improving system level efficiency over the entire load range Therearetwostandbymodesavailabletoreducetheinputpower under very light load conditions The first is Auto Standby mode which is internally triggered by periodic sensing and the other is a manual standby mode which is executed by clamping the secondary output In general applications the manualst...

Страница 2: ...ith latch Maximum on time limit Absolute Maximum Ratings at TA 25 C Parameter Symbol Conditions Rating Unit Drain Current1 IDpeak Single pulse 15 A Maximum Switching Current2 IDmax TA 20 C to 125 C 15 A Single Pulse Avalanche Energy3 EAS Single pulse VDD 99 V L 20 mH ILpeak 6 05 A 400 mJ Input Voltage for Controller MIC VCC 35 V SS OLP Terminal Voltage VSSOLP 0 5 to 6 0 V FB Terminal Inflow Curren...

Страница 3: ...igure 1 for MOSFET SOA temperature derating coefficient Figure 1 MOSFET Safe Operating Area Derating Curve Figure 2 MOSFET Safe Operating Area Drain Current versus Voltage at TA 25 C Single Pulse Terminal List Table Number Name Description Functions 1 D Drain MOSFET drain 2 NC Clipped No connection 3 S GND Source ground terminal MOSFET source and ground 4 VCC Power supply terminal Input of power s...

Страница 4: ...Thermal Resistance R QJC C W 0 001 0 010 0 100 1 000 10 000 100μ 10μ 10m 1m 100m 1μ Ambient Temperature TA C Power Dissipation P D1 W 0 5 10 15 20 25 30 0 20 40 60 80 100 120 140 160 PD1 1 3 W at TA 25 C Without heatsink With infinite heatsink PD1 29 W at TA 25 C Figure 3 MOSFET Avalanche Energy Derating Curve VDD 99 V L 20 mH IL 3 6 A Figure 4 Transient Thermal Resistance Figure 5 MOSFET Power Di...

Страница 5: ...nal Inflow Current Normal Operation IFB ON VFB 1 6 V 600 1000 1400 μA Standby Operation Standby Operation Start Voltage VCC S VCC 0 15 V VFB 1 6 V 10 3 11 1 12 1 V Standby Operation Start Voltage Interval VCC SK VCC SK VCC S VCC OFF 1 10 1 35 1 65 V Standby Non Operation Circuit Current ICC S VCC 10 2 V VFB 1 6 V 20 56 μA FB Terminal Inflow Current Standby Operation IFB S VCC 10 2 V VFB 1 6 V 4 14...

Страница 6: ...treatment Ni plating and solder dip Leadform 2003 Weight approximate 2 3 g Dimensions in millimeters Drawing for reference only Branding codes exact appearance at manufacturer discretion 1st line type STR 2nd line subtype W6756 3rd line lot YM DD Where Y is the last digit of the year of manufacture M is the month 1 to 9 O N D DD is the 2 digit date 1 2 3 4 5 6 7 Terminal dimensions at case surface...

Страница 7: ...r mounting the products the mounting surface flatness should be 0 05 mm or less Please select suitable screws for the product shape Do not use a flat head machine screw because of the stress to the products Self tapping screws are not recommended When using self tapping screws the screw may enter the hole diagonally not vertically depending on the conditions of hole before threading or the work si...

Страница 8: ...ative to discuss prior to the use of the products herein The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required aerospace equipment nuclear power control systems life support systems etc is strictly prohibited In the case that you use Sanken products or design your products by using Sanken products the reliability largely d...

Отзывы: