Sanipex BAGNODESIGN BDM-CUB-I301 Series Скачать руководство пользователя страница 9

13 cm

  Temperature setting 

Sensing Distance 13 cm 

Timeout protection: when the continuous use 

time exceeds 55' seconds, the sensor will 

automatically turn off the water, so as to 

avoid the phenomenon of continuous water 

flow caused by foreign objects in the sensor' 

range  and waste of water.

>

55sec

Содержание BAGNODESIGN BDM-CUB-I301 Series

Страница 1: ...BDM CUB I301 XX CUBE TOUCHLESS BASIN MIXER BATTERY OPERATED www sanipexgroup com ...

Страница 2: ......

Страница 3: ...facture after purchase This document can be found at www sanipexgroup com The life cycle of the product is no t in correlation to the product Guarantee the standards the products are manufactured or certified to e g CE WRAS can exceed past the Guarantee duration After the life cycle of the product is deemed complete by the end user please follow the below to dispose of the items correctly Mixers T...

Страница 4: ...Tools Required Not supplied ON OFF Always flush pipework before installation Electrical Cable Tap comes with pre installed flexible hoses ...

Страница 5: ...ification Electronic faucet Description DC 6V 4AA alkaline battery Power DC Standby 0 2mW Power Consumption 13 4 cm Sensing distance 0 5 Bar 5 Bar Water Pressure 20 60 Temperature G1 2 Ø of inlet pipet 7 6 L min Flux ...

Страница 6: ...Battery Holder X3 Batteries not included ...

Страница 7: ...ON Do not use any abrasive detergents or solvents containing alcohol metal or abrasive sponges ...

Страница 8: ... scans the use environment and then automatically sets the optimal sensing distance according to the scan parameters 3 min Automatically setting the initial value of the sensing distance The sensor first scans the use environment 8 times with power on to set the sensing distance ATTENTION do not shake hands or objects at the sensor window during the flash ...

Страница 9: ...3 cm Timeout protection when the continuous use time exceeds 55 seconds the sensor will automatically turn off the water so as to avoid the phenomenon of continuous water flow caused by foreign objects in the sensor range and waste of water 55sec ...

Страница 10: ...al problem Disconnect and connect the battery Lack of water supply Low feed pressure Check the water pressure Outlet plugged due to dirt or lime deposits remove and clean the aerator as shown on page 3 A Water keeps on running for more than 1minute without objects in front of the sensor Poor water flow PROBLEM SOLUTION Reverse the water outlet inlet The water opens on hot and gets cold only by adj...

Страница 11: ...Note ...

Страница 12: ...INM CUB I301 XX 06 22 www sanipexgroup com ...