Electrical requirements:

Electricity supply circuitry:

1. Test the voltage of electricity supply and make sure steam engine with suitable electric 

voltage should be used..

2. Insulated copper wire should be used with an anti-heat temperature of 90℃ and a specified 

voltage of 500V. Refer to national or local electricity consumption code for the 
specifications. Refer to the ammeter for the ampere.

3. Choose steam engine with suitable item number, and plug the ground wire into the ground 

terminal.

4. Install an independent circuit breaker between the power supply and the steam engine so as to 

provide an electricity supply with overflow protection and electricity leakage protection.

!

 

 

All the connection must be in accordance with national and local electricity 

consumption code and be installed by professional electricians.

Attention: 

Installation of the top light

Light is available in 12V/220V/230V outputs. Before connect to the light, please consult with 
manufacturer  to  know  what  voltage  the  light  is,  so  as  to  avoid  generator  damage  or cause 
danger.
If  the  light  output  is  12V,  the  power  of  the  light  should  not  be  more  than  35W,othwise, 
transformer  will  be  burned  and  cause  danger.  If  light  input  is  220v~240V,light  power 
should not more than 100W.

The  light  should  be  installed  on  the  top  of  the  steam  room  or  the  places  where  are  not 
access to the children.

OO

NN

IT

!

IU

   

A

     

T

CUAC

   

      

   

 The illustration is just for explaination, the practical installation must comply 

with  the  nation's  electric  criterion,and  processed  by  the  professional 

!

The steam control panel           

(Possible location)

The steam 
generator

Light

The steam outlet

The steam place under 

the wash parr (Possible 

location)

!

CAUTION:

CAUTION:

 

Take  some moisture proof measures in  process of installation. 

Can not let the electrical components be exposed to moisture or,  it will cause 

damage or short circuit.

CAUTIO N:

GEN4.5-1

Содержание BagnoDesign BDD-SPA-GEN4.5-1-A

Страница 1: ...BDD SPA GEN4 5 1 A BAGNOSPA STEAM GENERATOR 4 5KW 220V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com ...

Страница 2: ...e 5 Electric requirements 6 Installation of the top light 7 Choose your type of machine 8 Maintenance of the steam engine 8 Configuration of steam generator 9 Cleaning of the steam generator 10 Cleaning process 11 Trouble shooting 11 Common troubles trouble shooting methods 12 Ampere Meter 13 Technical parameter 14 Figure Heating element and Power line assemble illustration 15 19 ...

Страница 3: ...ich link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of the machine by the environment 4 Do not install it in the frigid loft or any places the water will freeze 5 Do not install it near the burnable and caustic object or chemical coal gas or dope thin...

Страница 4: ...ng for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep the outlet away from the people 12 The controller must be installed in the steam room please refer to the chapterinstruction of the controller s installation and operation of the manual The steam generator including the controller are comply with the CE and UL certific...

Страница 5: ...esistant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape to make sure that the cooled water will not stay in the curved pipe of the steam pipe 5 The shorter the steam pipe the better Try to decrease the number of elbows and avoid abrupt turns Attention Do...

Страница 6: ... effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using weight Attention The drainpipe should not incline upwards so as to facilitate the drainage of water Safety valve 1 Safety valve is a piece of safe equipment in order to prevent too much steam pressure i...

Страница 7: ... 4 5KW 264 5mm 372mm 6KW 9KW 372mm 264 5mm 333mm 372mm 162mm 333mm 372mm 200mm Safety valve Steam outlet Water inlet Water drain 162mm 333mm Manual water drain 200mm 333mm Water inlet Safety valve Steam outlet Manual water drain Water drain ...

Страница 8: ...llation of the top light Light is available in 12V 220V 230V outputs Before connect to the light please consult with manufacturer to know what voltage the light is so as to avoid generator damage or cause danger If the light output is 12V the power of the light should not be more than 35W othwise transformer will be burned and cause danger If light input is 220v 240V light power should not more th...

Страница 9: ...ls C Celia Heights exceeding 8 FT D Ceramic tile E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the tank is discharged completely before cutting off power supply 2 There should not be any leakage or damage among the steam engine steam nozzle components and pipes They should be checked and repaired an...

Страница 10: ...lation bracket 3 Circuit board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105O C Hi limit Transformer 11 12 Terminal block Fuse Earth wire connector 16 17 15 14 13 18 Relay Water level sensor Manual water drain 7 ...

Страница 11: ...off when from element and water tank When timer window shows countdown time is 00 00 TEMP window shows opl from hot pls switch on the manual drain ball valve at this time to drain the water from water tank When system detect lack of water for 1 minute system will switch on the water inlet valve to get water supply to water tank so as to continue cleaning water scale inside tank for 1 minute and dr...

Страница 12: ... E0 The temperature sensor open circuit Water level sensor failure checking the control cable connection between the control panel to steam generator is loose or not E02 The temperature sensor is Short circuit E03 Signal transfer fault between main panel and sub panel E04 Signal transfer fault between control panel and steam generator E12 E22 E32 E42 water inlet takes over 2 minutes E13 E23 E33 E4...

Страница 13: ...ether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water pipe connector becomes loose or the pipe breaks 2 Water leakage in the water input valve or the water drainage valve 1 Tighten the loose connector and change the broken pipe 2 Change the water input ...

Страница 14: ...ith overflow protection and electricity leakage protection Important The list above is for reference only In actual checking and repairing based on the national and local codes ask professional service personnel to operate Technical parameter Steam Volume ml min Steam Production Time S TYPE GEN4 5 1 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water...

Страница 15: ...igure Heating element and Power line assemble illustration 1 1 4 2 Black 3 0mm N L 3 2 3 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 3 0mm 3 0mm 3 0mm 3 0mm 2 0mm 12 30 01 Light 12V 5 20W Color Light 12V 10W G B VCC R Control Panel Music box WIFI box Sub Control Panel Horn2 Horn1 aroma pump Temp2 Temp1 25 c time Real time Real Internal wiring diagram of steam generator 4 5kw 220 240V 1phase ...

Страница 16: ... Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6kw 220 240V 1phase 1 1 4 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Страница 17: ...Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 7 5 9kw 220 240V 1phase 1 1 6 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm 5 6 4 5 2 0mm 2 0mm 2 0mm 2 0mm copper short circuit board ...

Страница 18: ...ontrol Panel Music box WIFI box Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6 9kw 380 415V 3phase 1 2 Black 2 0mm N L1 L2 L3 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Страница 19: ...Note ...

Страница 20: ...IND SPA GEN4 5 1 A 12 21 www sanipexgroup com ...

Отзывы: