Sanipex BAGNODESIGN BAGNOSPA BDD-SPA-GEN6-3-A Скачать руководство пользователя страница 6

!

Important:

  

1. Please consult your distributors of building materials like acryl, fiber glass or other anti-heat 

sheet about the installation position of steam nozzle. 

2. In the entire steam room, it is required that steam can not leak out. The pipes, its accessories 

and the holes in the wall should be air proof by applying air proof glue so that no steam will 
enter the holes in the wall.

If  non-heat-resistant  material  like  acrylic 
is used as building material, reserve a gap 
no  smaller  than  1/4''  and  fill  with 
heat-insulated material.

Airproof green material belt

Use  airproof  silicon  gel  or  

o r r e s p o n d i n g  a i r p r o o f 

material  to  fill  in  the  gaps  in the 

wall  to  achieve  the  water-proof 

and damp-proof effect.

Inside wall in the steam room

Drainpipe (1/2'')

According to national or local rules, the steam engine drainage valve should be equipped with drainpipe. 
The steam engine drains the water by using weight.

!

Attention:

  The drainpipe should not incline upwards so as to facilitate the drainage of water.

Safety valve

1. Safety valve is a piece of safe equipment in order to prevent too much steam pressure in the 

interior steam engine due to various reasons.

2. The pressure limit range of safety valve is 15 PSI and the pressure will begin to decrease if 

pressure should come over this value.

3. If it is allowed by local codes, provide the safety valve with exterior drainpipe.

!

Warning:

  

1. Do not dismantle the pressure decrease valve at random in case any danger should happen.

2. To maintain the proper and automatic operation of safety valve, make sure the safety valve

connection pipe is smooth.

GEN6-3

Содержание BAGNODESIGN BAGNOSPA BDD-SPA-GEN6-3-A

Страница 1: ...BDD SPA GEN6 3 A BAGNOSPA STEAM GENERATOR 6KW 380V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com ...

Страница 2: ... 5 Electric requirements 6 Installation of the top light 7 Choose your type of machine 8 Maintenance of the steam engine 8 Configuration of steam generator 9 Cleaning of the steam generator 10 Cleaning process 11 Trouble shooting 11 Common troubles trouble shooting methods 12 Ampere Meter 13 Technical parameter 14 Figure Heating element and Power line assemble illustration 15 19 ...

Страница 3: ...ich link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of the machine by the environment 4 Do not install it in the frigid loft or any places the water will freeze 5 Do not install it near the burnable and caustic object or chemical coal gas or dope thin...

Страница 4: ...g for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep the outlet away from the people 12 The controller must be installed in the steam room please refer to the chapterinstruction of the controller s installation and operation of the manual The steam generator including the controller are comply with the CE and UL certifica...

Страница 5: ...esistant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape to make sure that the cooled water will not stay in the curved pipe of the steam pipe 5 The shorter the steam pipe the better Try to decrease the number of elbows and avoid abrupt turns Attention Do...

Страница 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using weight Attention The drainpipe should not incline upwards so as to facilitate the drainage of water Safety valve 1 Safety valve is a piece of safe equipment in order to prevent too much steam pressure ...

Страница 7: ...n 200mm 333mm Water inlet Safety valve Steam outlet Manual water drain Water drain provided is limited do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion Caution To avoid damage to the equipment do not connect strong electric current directly to the components To facilitate maintenance keep the steam engine clean If the information Attention ...

Страница 8: ...on Installation of the top light Light is available in 12V 220V 230V outputs Before connect to the light please consult with manufacturer to know what voltage the light is so as to avoid generator damage or cause danger If the light output is 12V the power of the light should not be more than 35W othwise transformer will be burned and cause danger If light input is 220v 240V light power should not...

Страница 9: ...lls C Celia Heights exceeding 8 FT D Ceramic tile E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the tank is discharged completely before cutting off power supply 2 There should not be any leakage or damage among the steam engine steam nozzle components and pipes They should be checked and repaired a...

Страница 10: ...ation bracket 3 Circuit board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105O C Hi limit Transformer 11 12 Terminal block Fuse Earth wire connector 16 17 15 14 13 18 Relay Water level sensor Manual water drain 7 ...

Страница 11: ...off when from element and water tank When timer window shows countdown time is 00 00 TEMP window shows opl from hot pls switch on the manual drain ball valve at this time to drain the water from water tank When system detect lack of water for 1 minute system will switch on the water inlet valve to get water supply to water tank so as to continue cleaning water scale inside tank for 1 minute and dr...

Страница 12: ...E0 The temperature sensor open circuit Water level sensor failure checking the control cable connection between the control panel to steam generator is loose or not E02 The temperature sensor is Short circuit E03 Signal transfer fault between main panel and sub panel E04 Signal transfer fault between control panel and steam generator E12 E22 E32 E42 water inlet takes over 2 minutes E13 E23 E33 E43...

Страница 13: ...hether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water pipe connector becomes loose or the pipe breaks 2 Water leakage in the water input valve or the water drainage valve 1 Tighten the loose connector and change the broken pipe 2 Change the water input...

Страница 14: ... overflow protection and electricity leakage protection Important The list above is for reference only In actual checking and repairing based on the national and local codes ask professional service personnel to operate Technical parameter Steam Volume ml min Steam Production Time S TYPE GEN6 3 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank...

Страница 15: ...5 20W Color Light 12V 10W G B VCC R Control Panel Music box WIFI box Sub Control Panel Horn2 Horn1 aroma pump Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 4 5kw 220 240V 1phase Impor tant The parameter listed in the table will be varied from different place and temperature please consultate to the qualificatory designer and architect for the more detailed use ...

Страница 16: ...Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6kw 220 240V 1phase 1 1 4 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Страница 17: ...emp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 7 5 9kw 220 240V 1phase 1 1 6 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm 5 6 4 5 2 0mm 2 0mm 2 0mm 2 0mm copper short circuit board ...

Страница 18: ...ntrol Panel Music box WIFI box Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6 9kw 380 415V 3phase 1 2 Black 2 0mm N L1 L2 L3 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Страница 19: ...Note ...

Страница 20: ...IND SPA GEN6 3 A 12 21 www sanipexgroup com ...

Отзывы: