background image

11. Norms

This appliance conforms to EN 12050-3.
Lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical 
safety and electromagnetic compatibility.

SANIPLUS®

Société Française d’Assainissement

EN 12050-3

LA01-x10
220 - 240 V - 50 Hz -550 W - IP44  2,9A -   - 5,4 KG

12. Commissioning the unit

Once electrical and plumbing connections have been made, flush the WC once. The motor should run from 5 to 10 seconds (sometimes in 
several small bursts) to clear the waste (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is 
clear, and that the discharge hose is not kinked. Flush the WC checking that all seals, and connections are watertight. Check both the discharge 
pipework from the unit and the other sanitary appliances connections.
When pumping the water away from a washbasin, the unit will run in short bursts with an interval between each one.

13. Usage and Warning

WARNING!

If away for long periods (e.g. holidays) we recommend that you turn off the water supply to the WC served by the unit.
WCs connected to this unit can be used like any normal toilet, and it requires minimum maintenance. The unit will operate automatically as 
soon as the required level of water enters the case.

This unit is designed for use in the domestic environment.
WARNING!

Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, 
condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals 
can also cause damage to the unit, and will invalidate the guarantee.

14. Care of your unit

In order to remove scale and clean the macerator and the bowl, use a household descalent (like SANIFLO descaler). 
As a general rule, household disinfectants and bleaches designed for a normal WC are suitable for use with a Saniflo unit.
•   Disconnect the macerator power supply.
•   Pour an amount of descalent / bleach in the pan.
•  Flush the WC once.
•   Leave it to stand for 1 or 2 hours.
•   Re-connect the macerator power supply.
•   Rinse by operating the flushing system twice.
Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.

10. Electrical connection

 

The electrical installation should be carried out by a qualified person.

All wiring must conform to BS7671, 1992 requirements for electrical installations. The Sanitop requires a 
220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanitop to a conventional plug and 
socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanitop 
has an earth wire. The wires in the mains lead are coloured in accordance with the following code:

Brown – Live       Blue – Neutral       Green/Yellow – Earth

Warning:

 Ensure the electricity is turned OFF at the main switchboard before wiring to connector.

All work on cable, pressure chamber and motor should only be carried out by a qualified Sanitop servicing agent, 
as special tools are required.

UK – 230/240V 50Hz.

The unit should be installed so it is easily accessible/removable for possible maintenance.  
The unit should not be exposed to splashing in normal use.

CANADA

USA

EUR

CH

GB

Содержание Sanitop

Страница 1: ... functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included 32 x 50 90 x 110 A B C E x1 x1 x1 x1 Hose clip for discharge elbow 100mm Inlet Connector F G H x...

Страница 2: ...use only Installed and used correctly this unit will give consistent and reliable service You can find the technical data in step 9 4 Performance Curve Height and Length of the discharge pipe litre min Metres ø 32 0 10 20 30 40 50 60 70 80 90 8 7 6 5 4 3 2 1 0 EN 12050 3 0m 10m 20m 40m 60m 80m 90m 5m max 4m 3m 2m 1m The discharge pipe size for Sanitop can be 22mm or 32mm 1 ...

Страница 3: ...icient Fix the discharge pipe correctly with distances of not more than one metre between the fastenings M J 6 WC Connection First put some silicon or liquid soap on the WC spigot Fit the collar supplied on the bowl outlet Pull the flexible sleeve over the pan spigot Position the metal hose clip C over the edge of the flexible sleeve and tighten with a screwdriver Once the appliance has been posit...

Страница 4: ...ischarge pipe which rises up through the lid turn to the desired direction and secure with the metal hose clip provided 32 50mm B Then connect the hose to it using the 20 32mm metal hose clip K making sure the hose is not kinked See figs 1 and 2 for connections that may be required for sanitary appliances K E F G 1 2 A K B I K H A B ...

Страница 5: ...can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem 5 Ensure all external pipework is adequately lagged to avoid the possibility of freezing 6 The discharge pipework must be connected to the soil stack using an appropriate strap on boss N B Any elbow on the discharge...

Страница 6: ...wood or plastic objects will not be under guarantee Solvents acids and other chemicals can also cause damage to the unit and will invalidate the guarantee 14 Care of your unit In order to remove scale and clean the macerator and the bowl use a household descalent like SANIFLO descaler As a general rule household disinfectants and bleaches designed for a normal WC are suitable for use with a Sanifl...

Страница 7: ... Call approved service engineer The unit will reset itself The motor intermittently activates The connected sanitary devices are dripping The non return valve is faulty Check the installation upstream Clean or replace the non return valve externally mounted The water in the WC pan goes down very slowly and is pumped away in bursts The air vent under carbon filter is clogged up The WC pan is partia...

Страница 8: ...tern Drain down any vertical discharge pipework and remove discharge hose from elbow Disconnect any inlet pipes from the unit Unscrew the 2 fastening screws to the floor if fitted Loosen the metal clip securing the flexible connector and pull off the WC spigot now slide the unit out from behind the WC 1 2 3 4 5 6 18 Guarantee 2 years guarantee as from its date of purchase subject to correct instal...

Страница 9: ...19 Parts ...

Отзывы: