11. Norms
This appliance conforms to EN 12050-3.
Lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical
safety and electromagnetic compatibility.
SANIPLUS®
Société Française d’Assainissement
EN 12050-3
LA01-x10
220 - 240 V - 50 Hz -550 W - IP44 2,9A - - 5,4 KG
12. Commissioning the unit
Once electrical and plumbing connections have been made, flush the WC once. The motor should run from 5 to 10 seconds (sometimes in
several small bursts) to clear the waste (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is
clear, and that the discharge hose is not kinked. Flush the WC checking that all seals, and connections are watertight. Check both the discharge
pipework from the unit and the other sanitary appliances connections.
When pumping the water away from a washbasin, the unit will run in short bursts with an interval between each one.
13. Usage and Warning
WARNING!
If away for long periods (e.g. holidays) we recommend that you turn off the water supply to the WC served by the unit.
WCs connected to this unit can be used like any normal toilet, and it requires minimum maintenance. The unit will operate automatically as
soon as the required level of water enters the case.
This unit is designed for use in the domestic environment.
WARNING!
Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton,
condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals
can also cause damage to the unit, and will invalidate the guarantee.
14. Care of your unit
In order to remove scale and clean the macerator and the bowl, use a household descalent (like SANIFLO descaler).
As a general rule, household disinfectants and bleaches designed for a normal WC are suitable for use with a Saniflo unit.
• Disconnect the macerator power supply.
• Pour an amount of descalent / bleach in the pan.
• Flush the WC once.
• Leave it to stand for 1 or 2 hours.
• Re-connect the macerator power supply.
• Rinse by operating the flushing system twice.
Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.
10. Electrical connection
The electrical installation should be carried out by a qualified person.
All wiring must conform to BS7671, 1992 requirements for electrical installations. The Sanitop requires a
220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanitop to a conventional plug and
socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanitop
has an earth wire. The wires in the mains lead are coloured in accordance with the following code:
Brown – Live Blue – Neutral Green/Yellow – Earth
Warning:
Ensure the electricity is turned OFF at the main switchboard before wiring to connector.
All work on cable, pressure chamber and motor should only be carried out by a qualified Sanitop servicing agent,
as special tools are required.
UK – 230/240V 50Hz.
The unit should be installed so it is easily accessible/removable for possible maintenance.
The unit should not be exposed to splashing in normal use.
CANADA
USA
EUR
CH
GB
Содержание Sanitop