background image

5. Installation

WARNING:

 The unit must be connected to WC pan with a horizontal outlet spigot conforming to EN33 or EN 37.

The unit should be accessible for possible service.
It is supplied with floor fixing lugs to prevent it from moving during use.
To optimise the latest technical developments concerning soundproofing incorporated into this unit, it is important to:

•  Position the WC pan so that it is not in contact with a partition or wall of the room.
•   Place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient.
•   Fix the discharge pipe correctly, with distances of not more than one metre between the fastenings.

M

J

6. WC Connection

•   First, put some silicon or liquid soap on the WC spigot.
•   Fit the collar supplied on the bowl outlet.
•   Pull the flexible sleeve over the pan spigot.
•   Position the metal hose clip (

C

) over the edge of the flexible sleeve and tighten with a screwdriver.

•   Once the appliance has been positioned, fix it to the floor using the 2 screws (

J

) supplied.

WARNING!  There should be no water dripping from the WC cistern. If there is, this will cause the unit to activate repeatedly as it pumps 
the water away.

The Saniflo unit and all its connections should be easily accessible for possible maintenance / removal.

1

2

C

J

Содержание Saniplus

Страница 1: ...e to follow instructions could result in poor functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included 32 x 50 90 x 110 A B C x1 x1 x1 Hose clip for disch...

Страница 2: ...ed and used correctly this unit will give consistent and reliable service You can find the technical data in step 8 4 Performance Curve Height and Length of the discharge pipe litre min Metres ø 32 0 10 20 30 40 50 60 70 80 90 8 7 6 5 4 3 2 1 0 EN 12050 3 0m 10m 20m 40m 60m 80m 90m 4m 3m 2m 1m The discharge pipe size for Saniflo can be 22mm or 32mm 1 ...

Страница 3: ...ts are fully efficient Fix the discharge pipe correctly with distances of not more than one metre between the fastenings M J 6 WC Connection First put some silicon or liquid soap on the WC spigot Fit the collar supplied on the bowl outlet Pull the flexible sleeve over the pan spigot Position the metal hose clip C over the edge of the flexible sleeve and tighten with a screwdriver Once the applianc...

Страница 4: ...nstalled to allow the discharge pipework to be drained down before any service work 4 If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem 5 Ensure all external p...

Страница 5: ... unit 9 Electrical connection The electrical installation should be carried out by a qualified person All wiring must conform to BS7671 1992 requirements for electrical installations The Saniflo requires a 220 240V single phase AC 50 Hz supply UK specification Do not connect the Saniflo to a conventional plug and socket It must be wired into a fused unswitched fixed wiring connector fitted with a ...

Страница 6: ...on filter and requires no external venting This filter has to be changed every year DISCONNECT THE ELECTRICAL POWER SUPPLY BEFORE ATTEMPTING ANY WORK ON THE UNIT 12 Usage and Warning WARNING If away for long periods e g holidays we recommend that you turn off the water supply to the WC served by the unit WCs connected to this unit can be used like any normal toilet and it requires minimum maintena...

Страница 7: ... dripping The non return valve is faulty Check the installation upstream Clean or replace the non return valve externally mounted The water in the WC pan goes down very slowly and is pumped away in bursts The air vent under carbon filter is clogged up The WC pan is partially blocked Clear the air vent Clear the WC pan The motor operates normally but continues to run for a long time The length or h...

Страница 8: ...tern Drain down any vertical discharge pipework and remove discharge hose from elbow Disconnect any inlet pipes from the unit Unscrew the 2 fastening screws to the floor if fitted Loosen the metal clip securing the flexible connector and pull off the WC spigot now slide the unit out from behind the WC 1 2 3 4 5 6 17 Guarantee 2 years guarantee as from its date of purchase subject to correct instal...

Страница 9: ...18 Parts ...

Отзывы: