Sangamo S250 Series Скачать руководство пользователя страница 9

Manual Button

Specification

Pressing the manual button M (Fig. 2) immediately opens or closes the switch contacts,

anticipating the next operation. This does not affect subsequent operations of levers L.

To Convert Form 2 Dial to Form 1

(i.e. from ‘2 ON/OFFs’ to ‘1 ON/OFF’)

1. 

Remove centre locking nut and lift away the dial face.

2. 

Remove the top ON/OFF lever and washers.

3. 

Replace the dial face.

4. 

Replace the locking nut.

Current, Voltage, Frequency:

As shown on identification plate of switch.

Ambient Temperature:

As shown on identification plate of switch.

Live Parts:

Enclosed i.e. this timer is totally protected by the enclosure.

Dirt Protection:

Normal domestic dust deposits only.

Moisture Protection:

Ordinary i.e. has no special protection against moisture.

Shock Protection:

Class 1. Functional insulation throughout.
The timer must be earthed.

Contacts:

Micro-disconnection

Important

Although every care is taken to ensure the accuracy of the electrical circuit diagrams shown, SANGAMO

or associated companies cannot be held responsible or liable for circuit connections other than those directly

associated with the S250 & Q550 ranges of time switches. As the control mechanism is similar to that

used in an  ordinary quartz clock, there will be a perceptual ticking.

Due to the variety of loads, environment and applications, the battery is built into the circuit of the printed

circuit board and, therefore, the timeswitch will cease to operate or run slow after its expectancy life of

10 years (dependant on the environment).

A battery replacement kit for fitting by a suitably qualified person is available by contacting our customer

services department.

9

39659_Sangamo  18/1/05  11:52 am  Page 9

Содержание S250 Series

Страница 1: ...SERIES ELECTRO MECHANICAL ROUND PATTERN TIME SWITCH Installation and User Instructions 39659_Sangamo 18 1 05 11 52 am Page 1...

Страница 2: ...e instructions carefully FIG 1 The Installation of the switch should be carried out by a qualified electrician in accordance with the current edition of the IEE wiring regulations To comply with safet...

Страница 3: ...attery providing a 100 hour reserve in the event of a power failure With the easily read dial face marked in 15 minute divisions these switches also offer high timing resolution permitting power to be...

Страница 4: ...ARM A OPERATING PIN SCREW N MANUAL BUTTON M OMIT DISC D DIAL SCREW B TARGET LEVERS L EARTH CONNECTION T DIAL KNOB H TARGET LEVER L CAPTIVE SCREW F TERMINAL COVER E Sangamo solar dial time switch Q550...

Страница 5: ...00 hour reserve will be achieved after approx 300 hours of power d This product is only suitable for Ordinary conditions i e this product is not protected against dripping or splashing moisture e When...

Страница 6: ...1 clockwise for that day with screwdriver until arrowhead points outwards For change over switches with levers marked A and B this device omits B lever operations 1 To set lever E slacken screw S and...

Страница 7: ...of operating arms A and K Fig 2 c To compensate for longitudinal errors variations of switch operating times for a period of approximately 3 4 hour either side of sunset or sunrise can be achieved by...

Страница 8: ...ithin this range To enable setting to be made it is necessary to remove screw B Fig 2 and lift dial assembly off central spindle WARNING Do not loosen the centre nut surrounding dial screw B 2 To set...

Страница 9: ...moisture Shock Protection Class 1 Functional insulation throughout The timer must be earthed Contacts Micro disconnection Important Although every care is taken to ensure the accuracy of the electrica...

Страница 10: ...Q554 Q N 1 24 HR Y ON SPST 3 6 Q555 Q N 1 24 HR Y ON SPST 4 6 Q557 Q N 1 24 HR Y OFF SPST 4 6 Q559 Q N 1 24 HR Y ON OFF SPST 4 4 Q563 Q N 1 24 HR Y ON SPDT 4 6 Q586 Q N 1 24 HR Y ON ON SPST 4 4 FUNCT...

Страница 11: ...40min 32min 24min 16min 8min 8min TIME ZONES FOR UK SOLAR MODELS GEOGRAPHICAL ZONES Because the times of sunrise and sunset vary with latitude four standard dials are available for use in the UK each...

Страница 12: ...environmental recycling recovery and or disposal Please mark your return packaging for the attention of the E O L Department The product that you have just purchased may contain some components recov...