background image

 

 

pictures. A1 connects to B1, and A2 connects to B2. It cannot plug if connecting A1 to B2. 

   

 

 

 
3.3 Use some power of your hands to plug it. When you plug one well, you can hear the click – the button 
springs and it locks. Then you can try to pull the handpiece connector slightly to check whether or not it 
locks well. Then hang up the two handpieces onto handpiece holders. 

 

 

 

 

Machine part 

Handpiece part 

A1 

B1 

B2 

A2 

Содержание LS10

Страница 1: ...Triple Diode Laser 808nm 1064nm 755nm Hair Removal System Operation Manual Model Name LS10...

Страница 2: ...1 Introduce Front View Back view Emergency Key Switch 10 4 movable touch screen Triple diode laser handpiece Electrical power port Water Overflow hole Discharge hole Interlock Water Injection hole Air...

Страница 3: ...ry careful to remove the cap above to avoid a damage on water valves There is video to show you how to remove it The method to take down the overflow plugs is to 1 push in the valve as below and at th...

Страница 4: ...e water valves as below to prevent the residual water from leaking 2 Install the handpiece holder 3 Connect the handpiece onto the machine 3 1 Press down the 2 buttons firstly There are two buttons on...

Страница 5: ...power of your hands to plug it When you plug one well you can hear the click the button springs and it locks Then you can try to pull the handpiece connector slightly to check whether or not it locks...

Страница 6: ...into the water injection hole and inject water until water runs out from overflow hole That means the water tank in the machine is full of water Then close the water overflow hole Chapter 3 Operation...

Страница 7: ...3 Turn on key switch and emergency switch Turn on the screen...

Страница 8: ...SR is skin rejuvenation Click HR into treatment interface Energy 1 100 adjustable Pulse Width 5 400 adjustable Frequency 1 10 adjustable You can also adjust the contact cooling on handpiece this area...

Страница 9: ...How to store settings E g you have got a good settings as below for a skin type You will click the settings are stored Chapter 4 Treatment 1 Operation Steps 1 Shave the hair in the treatment area...

Страница 10: ...the penetration The light pulse irradiates on the cold gel every area that need light pulse treatment should be pasted by new cold gel 4 Switch the key clockwise to start the machine and then the scre...

Страница 11: ...d then turn off the key The Quick stop Button is designed to shut off the laser not shut off the VAC The Key is designed to shut off the VAC input 2 Treatment Notice 1 The treatment of the hair remova...

Страница 12: ...ser pulses to eyes or watch the laser directly Chapter 5 Maintenance and Warranty This chapter descript the daily maintenance including cleaning the system cleaning the crystal Water Filter The water...

Страница 13: ...The treatment head should always be kept clean clean of the treatment head is necessary after each treatment When cleaning the treatment head you can use wet soft clothes and then air it to become com...

Страница 14: ...treatment head is near the limit of useful life Chapter 6 Parameters 6 1 Basic parameter Settings Dark hair Short pulse width light hair Long pulse width Thick hair Long interval low energy Thin hair...

Страница 15: ...post exposure recently or sun exposure customer 10 recent days within 3 months using cosmetics containing hormones such as some freckle products customers 11 epilepsy diabetes bleeding tendency custom...

Страница 16: ...phenomenon After treatments later it will go away within a few hours 7 the treatment parameters settings should be recorded for later use 8 20 minutes after the treatment finished washed cold gel do c...

Страница 17: ...re the laser pulse launching after the system ready to issue a beep sound 7 4 4 photo Photographic archive for the patient before and after surgery the patient face left right and front Because many p...

Страница 18: ...also be used to reduce swelling If the blisters scab available moisture ointment like Vaseline to keep it moist 7 6 2 to prevent sun exposure one month after treatment patients should used high facto...

Страница 19: ...kin Add synthesis of vitamin C cream on the skin Add sunscreen on the skin Night Clean the skin Apply moisturizing cream 7 7 Advantage of the treatments 1 no damage 2 the pain is not obvious 3 fast ef...

Страница 20: ...e settings base on the following chart according to different people Skin type Laser Power Pulse Width Frequency 1 50 50 3 5 2 40 45 3 5 3 15 40 3 5 4 15 35 3 5 5 15 20 3 5 6 10 10 3 5 Specifications...

Отзывы: