KBox C-103-CFL-x - User Guide, Rev. 1.0
// 63
8/
Installation Instructions
The KBox C-103-CFL comes with attached wall mount brackets. The available mounting key holes (Figure 25, pos. 1
and pos. 3) of the wall mounting brackets allow the unit attaching to a wall of a fire resistant enclosure.
Please observe the following safety and installation instructions:
Whenever possible, unpack or pack this product only at EOS/ESD safe work stations. Where a safe work station is
not guaranteed, it is important for the user to be electrically discharged before touching the product with his/her
hands or tools. This is most easily done by touching a metal part of the system chassis.
Do not handle this product out of its protective enclosure while it is not used for operational purposes unless it is
otherwise protected.
Prior any installation work ensure that there are no live wires on the installation site
Do not handle the device if there is any damage visible.
Do not operate the KBox C-103-CFL with foreign objects inside the chassis.
Further do not insert any retrieval device into the device while it is connected to power.
Kontron rejects all liability for any and all damages resulting from operation of the unit with foreign objects
inside the chassis.
The KBox C-103-CFL has to be installed and operated only by trained and qualified personnel.
The KBox C-103-CFL system is designed for usage within control cabinets only.
Only personnel with appropriate qualifications, trainings and authorization are permitted to install and work with
the Kontron KBox C-103-CFL.
This device shall only be installed in or connected to systems that fulfill all necessary technical and specific
environmental requirements.
The KBox C-103-CFL system is designed to be operated in vertical position with attached mounting brackets as
shown in Figure 6 and Figure 7. It is not allowed to install the KBox C-103-CFL as a stand-alone (desktop) device.
Do not remove the wall mounting brackets.
The unit must be placed such that there is sufficient space in front of it for connecting the cables to the I/O
interface connectors and for operating the power button.
Leave sufficient free space around the unit to prevent the device from possibly overheating!
To ensure proper operation, we recommended free space as specified below:
above and below: 100 mm (3.937")
left and right: 50 mm (1.96").
See also Figure 46 to Figure 52 section 12.1 “Mechanical Specifications”.
It must be observed that all ventilation openings are not covered/obstructed by objects.
The KBox C-103-CFL must be firmly attached to a clean flat and solid mounting surface. Use proper fastening
materials suitable for the mounting surface. Ensure that the mounting surface type and the used mounting
solution safely support the load of the KBox C-103-CFL and the attached components.
Please follow the local/national regulations for grounding.
The voltage feeds must not be overloaded. Adjust the cabling and the overcurrent protection to correspond with
the electrical figures indicated on the type label.
The type label is located on the right side of the system.
It is recommended that the last cable attached to the system should be the power cable! Refer to the section 8.3
“DC Power Plug Terminal” and chapter 9/ “Starting Up”.
The unit is to be connected only to internal Ethernet networks without exiting a facility and being subjected to
TNVs.
External circuits connected to the device shall be SELV/PELV (galvanic seperated from mains by double or
reinforce insulation).
Use copper conductors only if the field wiring terminal is only for connection to copper wire.
Minimum temperature rating of the cables connected to the field wiring terminals is 75° C.
Содержание Kontron KBox C-103-0
Страница 2: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank...
Страница 28: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 28 Figure 12 Block Diagram KBox C 103 CFL x...
Страница 124: ...KBox C 103 CFL x User Guide Rev 1 0 www kontron com 124...