Sandpiper SB1 Скачать руководство пользователя страница 10

sb1dl5sm-rev0317

sandpiperpump

.

com

7

 • Model SB1 & SB25 

Troubleshooting Guide

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

Symptom:

Potential Cause(s):

Recommendation(s):

Pump Cycles Once

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.  

(Does not apply to high pressure 2:1 units).

Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.
Bent or missing actuator plunger.

Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate 

/ Cycle

Pump is over lubricated.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Lack of air (line size, PSI, CFM).

Check the air line size and length, compressor capacity (HP vs. cfm required).

Check air distribution system.

Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. 

Discharge line is blocked or clogged manifolds.

Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.  

(Does not apply to high pressure 2:1 units).

Blocked air exhaust muffler.

Remove muffler screen, clean or de-ice, and re-install. 

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump chamber is blocked.

Disassemble and inspect wetted chambers. Remove or flush any obstructions. 

Pump Cycles and Will 

Not Prime or No Flow

Cavitation on suction side.

Check suction condition (move pump closer to product).

Check valve obstructed. Valve ball(s) not seating 

properly or sticking.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.  

Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. 

Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or 

manifold).

Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical  

Resistance Guide for compatibility.

Valve ball(s) / seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.
Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump Cycles Running  

Sluggish / Stalling, 

Flow Unsatisfactory

Over lubrication.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Icing.

Remove muffler screen, de-ice, and re-install. Install a point of use air drier. 

Clogged manifolds.

Clean manifolds to allow proper air flow.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow.  

(Does not apply to high pressure 2:1 units).

Cavitation on suction side.

Check suction (move pump closer to product).

Lack of air (line size, PSI, CFM).

Check the air line size, length, compressor capacity.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Air supply pressure or volume exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. 

Undersized suction line.

Meet or exceed pump connections. 

Restrictive or undersized air line.

Install a larger air line and connection. 

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary.

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. 

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates are tight.

Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility 

with products, cleaners, temperature limitations and lubrication.

Premature Diaphragm 

Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction pressure.

Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure. 

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical incompatibility).

Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations 

and lubrication.

Incorrect diaphragm plates or plates on backwards, 

installed incorrectly or worn.

Check Operating Manual to check for correct part and installation. Ensure outer plates have not been 

worn to a sharp edge.

Unbalanced Cycling 

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. 

MODEL SPECIFIC

2: INST

AL

 & OP

Содержание SB1

Страница 1: ...allic Design Level 5 Warren Rupp Inc A Unit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certified SERVICE OPERATING MANUAL Original Instructions 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 AIR END 5 WET END 6 OPTIONAL 7 WARRANTY ...

Страница 2: ...t or solidify the pump should be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV stabili...

Страница 3: ...Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Valve Assembly for Aluminum Center Sections Air Valve Assembly for Cast Iron Center Sections Pilot Valve Assembly SECTION 5 WET END 15 Diaphragm Drawings Diaphragm Servicing SECTION 6 OPTIONAL CONFIGURATIONS 17 Dual Port SECTION 7 WARRANTY CERTIFICATES 19 Warranty EC Declaration of Conformity Machine...

Страница 4: ...Cast Iron Air SS Stainless Steel Wetted Aluminum Air HC Alloy C Wetted Aluminum Air HI Alloy C Wetted Cast Iron Air Pump Series S SANDPIPER Pump Design B Soilid Ball Pump Size 1 1 25 1 BSPT Tapered Thread Discharge Porting Position D Bottom S Side T Top ET Dual Top ES Dual Side Options P1 Intrinsically Safe ATEX Compliant Pulse Output __ __ _____ __ ___ __ __ Pump Pump Pump Size Discharge Diaphrag...

Страница 5: ...ly polar solvents like acetone and MEK ozone chlorinated hydrocarbons and nitro hydrocarbons 190 F 88 C 10 F 23 C Nylon 6 6 High strength and toughness over a wide temperature range Moderate to good resistance to fuels oils and chemicals 180 F 82 C 32 F 0 C Polypropylene A thermoplastic polymer Moderate tensile and flex strength Resists stong acids and alkali Attacked by chlorine fuming nitric aci...

Страница 6: ... EXHAUST 3 4 NPT SUCTION PORT 1 NPT SB1 1 BSPT SB25 AIR INLET 1 2 NPT DISCHARGE PORT 1 NPT SB1 1 BSPT SB25 4X 28 7 MOUNTING HOLE NOTE UNIT FURNISHED WITH SUB BASE PLATE AND RUBBER FEET AS STANDARD FOR STATIONARY BOLT DOWN USE RUBBER FEET CAN BE REMOVED SB1 SB25 HEAVY DUTY BALL VALVE PUMP DIMENSIONAL TOLERANCE 1 8 3 XX MILLIMETERS F 1 REVISED VALVE CONFIGURATION MF 11 9 2011 REV REVISION CHG DATE A...

Страница 7: ...0 5 86 149 15 36 390 14 49 368 CAST IRON CENTER SECTION 4 10 104 5 54 141 15 06 383 15 69 398 PULSE OUTPUT CONFIGURATION D 11 36 288 9 00 229 8 56 217 4X 28 7 MOUNTING HOLE NOTE UNIT FURNISHED WITH SUB BASE PLATE AND RUBBER FEET AS STANDARD FOR STATIONARY BOLT DOWN USE RUBBER FEET CAN BE REMOVED 72 18 64 16 8 43 214 7 62 194 A B C 6 82 173 DISCHARGE PORT 1 NPT SB1 1 BSPT SB25 SUCTION PORT 1 NPT SB...

Страница 8: ...check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulled through its stroke The diaphragm s inner plate makes contact with an actuator plunger aligned to shift the pilot signaling valve Once actuated the pilot valve sends a pressure signal to the opposi...

Страница 9: ...ausing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to increase air flow as desired If opening the valve increases cycling rate but does not increase the rate of flow cavitation has occurred The va...

Страница 10: ...nt of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Check suction move pump closer to product Lack of air line size PSI CFM Check the air line si...

Страница 11: ...s Plungers and Retaining Rings 476 341 000 Air End Refurbishment Kit With new die cast aluminum air valve body Bumpers Bushings Gaskets O rings Seals Plungers and Retaining Rings 476 313 000 Air End Refurbishment Kit For cast iron centers with conductive polypropylene air valve body Bumpers Bushings Gaskets O rings Seals Plungers and Retaining Rings 476 309 354 Wet End Kit Santoprene Diaphragms Sa...

Страница 12: ... 003 110 PLUG PIPE STAINLESS STEEL ONLY 2 618 003 112 PLUG PIPE ALLOY C ONLY 2 618 003 330 PLUG PIPE ALUMINUM ONLY 2 Composite Repair Parts List ATEX Compliant LEGEND Items contained within Air End Kits Items contianed within Wet End Kits Air End Kit only includes sleeve and spool set not entire air valve assembly Note Kits contain components specific to the material codes Item Part Number Descrip...

Страница 13: ...ubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 150 520 Injection Molded PVDF Natural co...

Страница 14: ... Sleeve Spool Set 1 1B 095 113 157 Body Valve 1 1C 132 037 357 Bumper 2 1D 165 129 157 Cap End 2 1E 170 032 330 1 4 20 X 3 4 Capscrew 8 1F 560 058 360 7 8 ID X 1 16 CS O Ring 8 Air Distribution Valve Servicing See repair parts drawing remove screws Step 1 Remove hex capscrews 1E Step 2 Remove end cap 1D Step 3 Remove spool part of 1A caution do not scratch Step 4 Press sleeve 1A from body 1B Step ...

Страница 15: ...pair parts drawing remove screws Step 1 Remove end cap retainer 1E Step 2 Remove end cap 1C Step 3 Remove spool part of 1A caution do not scratch Step 4 Press sleeve 1A from body 1B Step 5 Inspect O Ring 1D and replace if necessary Step 6 Lightly lubricate O Rings 1D on spool 1A Step 7 Press sleeve 1A into body 1B Step 8 Reassemble in reverse order Note Sleeve and spool 1A set is match ground to a...

Страница 16: ...3 360 O Ring 4 4D 775 014 115 Pilot Valve Spool 1 4E 560 023 360 O Ring 4 4F 675 037 050 Retaining Ring 1 Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 4F Step 2 Remove sleeve 4B inspect O Rings 4C replace if required Step 3 Remove spool 4D from sleeve 4B inspect O Rings 4E replace if required Step 4 Lightly lubricate O Rings 4C and 4E Reassemble in reverse order...

Страница 17: ...14 Diaphragm Service Drawing with Overlay Diaphragm Service Drawing One Piece Bonded Diaphragm Service Drawing 20 46 50 7 38 21 11 33 44 18 39 Torque 350 in lbs 20 46 50 7 38 11 33 44 18 21 22 39 Torque 450 in lbs 20 46 50 7 38 21 11 33 44 18 5 WET END ...

Страница 18: ...together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate for stress relaxation in the clamped assembly Step 6 Thread one assembly onto the diaphragm rod with sealing washer when used and bumper Step 7 Install diaphragm rod assembly into pump and secure by ins...

Страница 19: ...P Tapered 1 334 036 156 Flange Dual Porting 1 NPT 1 334 036 156 E Flange Dual Porting 1 BSP Tapered 1 56 170 125 330 Capscrew Hex 5 16 18 UNC 2A X 6 00 3 Dual Port Options Illustration for Dual Port Suction and Single or Dual Port Discharge Dual Port Suction and Discharge Repair Parts List Item Part Number Description Qty 15 170 122 330 Capscrew Hex 5 16 18 UNC 2A X 5 00 3 55 334 036 110 Flange Du...

Страница 20: ...8 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that no product sold by Warren Rupp that bears a Warren Rupp brand shall fail under normal use and service due to a defect in material or workmanship within five years from the date of shipment from Warren...

Страница 21: ...edge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X DEKRA Certification B V 0344 Meander 1051 6825 MJ Arnhem The Netherlands Applicable Standard EN13463 1 2001 EN13463 5 2003 EN60079 25 2004 Harmonised Standard EN13463 1 2009 EN13463 5 2011 EN6007...

Отзывы: