TD - MIXVENT SERIES

The TD - MIXVENT mixed flow range of in-line duct exhaust fans have been manufactured in accordance with the rigorous standards 
of production as defined by the International Quality Standards ISO 9001. All the components have been checked and tested at the 
end of the manufacturing process.

We recommend that you check the following after receiving this product:

1. The correct size has been received
2. The correct model has been received
3. The details on the rating label correspond to the electrical supply: voltage, frequency etc.

Remove the unit from packaging and inspect for shipping damage within 15 days of receipt. If the product is found to be damaged, 
immediately contact your local authorized supplier. DO NOT OPERATE THE UNIT IF DAMAGED.

These instructions should be considered as a supplement to EPA standard practices, as well as all state and local building code regula-
tions.

ENVIRONMENT

The TD-Mixvent series of fans are suitable for operation within indoor environments only, except the TD-250 and 315x which are 
UL approved for outdoor use. The TD-Mixvent units are suitable for the exhaust or supply of both conditioned and un-conditioned 
airstreams within the temperature ranges (inclusive of duct airstream’s temperature) of -40°C up to +40°C for models TD-100,-
100X, -125 & -150; and -40°C up to +60°C for models TD-200, -200X,-250 & -315. 

INSTALLATION

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOL-
LOWING:

(a) Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
(b) Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked; securely 
fasten a prominent warning device such as a tag to the service panel.

(c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes & stan-

dards including fire rated construction.

(d) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-

ment to prevent back drafting. Follow the heating equipment manufacturers guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA) and the American Society For Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE) and the local code authorities.

(e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
(f)  Ducted fans must always be vented to the outdoors.
(g) If this unit is to be installed over a tub or a shower, it must be marked as appropriate for the application and connected to a 

GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

(h) Never place a switch where it can be reached from a tub or shower.
(i)  CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
(j)  CAUTION:  MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2.4 M (8 FEET) ABOVE THE FLOOR OR GRADE 

LEVEL.

(k) All units are suitable for use with solid-state speed control.

The TD - MIXVENT series can be mounted in any orientation, horizontal or vertical, and is suitable for numerous types of applica-
tions. See 

Figure (1)

. Illustration of some typical applications.

If the installation is made to rigid or flexible ducting, then we would recommend the correct diameter ducting is used to couple to the 
fan flanges. If it is necessary to bend the duct at the discharge of the fan, then the bend radius should be as large as possible.

Before installing the product check the following points: (1) the fan impeller turns freely and (2) there are no obstructions to the 
airflow.

5

Содержание TD-100

Страница 1: ...Kit TD 150 INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS ...

Страница 2: ...D a ojando los tornillos de las bridas de sujeción 2 Fijar el soporte del TD en el sitio deseado y volver a montar el cuerpo motor en su soporte teniendo en cuenta el sentido del ujo de aire indicado por la echa marcada en el cuerpo motor 3 Estirar y cortar el tubo flexible a las dimensiones necesarias para la aspiración y la descarga El tubo flexible debe estar bien estirado 4 Empalmar los tubos ...

Страница 3: ...ion PG Séparer la bride de la bouche PG Passer le conduit flexible par le trou et le raccorder à la bride Fixer la bride au plafond et remonter la bouche dans la bride 6 Percer le mur ou le plafond à l endroit où doit être montée la grille extérieure GR Passer le conduit flexible par le trou et le raccorder à la grille Fixer la grille au mur ou au plafond 7 Raccorder le TD au réseau électrique Le ...

Страница 4: ...ANTE TODOS LOS TD MIXVENT INCORPORAN UN MOTOR 120V 60Hz DE DOS VELOCIDADES LA FASE TIENE QUE CONECTARSE ÚNICAMENTE AL TERMINAL HI O LO NO A LOS DOS A LA VEZ Figure 3 Electrical Wiring Conexión Eléctrica Branchement Electrique TD MIXVENT flow Motor without Speed Controller Motor sin regulador de velocidad Moteur sans régulateur de vitesse Models TD 100 100x 125 150 200x are double insulated and are...

Страница 5: ... disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes stan dards including fire rated construction d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equip me...

Страница 6: ...ate of original purchase In the event that we find any part is defective the product will be repaired or in the Company s discretion replaced without charge provided that the product has been installed in accordance with the enclosed instructions and all applicable EPA Standards and state and local building codes Soler Palau TD Bath Kits have an extended warrranty period of 7 years from the date o...

Страница 7: ...ia muy visible al cuadro de mandos c La instalación y la conexión eléctricas deben ser realizadas por un profesional cualificado de acuerdo con las normativas y reglamentos vigentes incluyendo las construcciones clasificadas al fuego d Prever la cantidad de aire suficiente para la combustión y evacuación de gases a través de una chimenea de una caldera fuel para evitar retorno de gases de combusti...

Страница 8: ...riodo de cinco 5 años a partir de la fecha de adquisición En el caso de que una pieza sea defectuosa el producto será reparado o reemplazado sin cargo siempre y cuando éste haya sido instalado de acuerdo con las instrucciones adjuntas y de acuerdo a las Normativas EPA vigentes a las locales y a las del estado de la construcción Soler Palau ha extendido la garantía de los juegos del baño a siete añ...

Страница 9: ...e l appareil ne soit accidentellement reconnecté Si le système de déconnexion ne peut être verrouillé fixez et assurez un panneau d avertissement très visible au tableau de commandes c L installation et le branchement électriques doivent être réalisés par un professionnel qualifié et conformément aux régle mentations et règlements en vigueur y compris les constructions classées contre le feu d Pré...

Страница 10: ...ez la avec un linge humide mais pas mouillé N utilisez pas de détergent ou de produits abrasifs pour le nettoyage DE GARANTIE Soler Palau USA Soler Palau Canada garantit les ventilateurs de la série TD MIXVENT contre les défauts de fabrication ou de matériaux pour une période de cinq 5 ans à compter de la date d acquisition En cas de pièce défectueuse le produit sera réparé gratuitement à conditio...

Страница 11: ......

Страница 12: ... Powers Avenue Jacksonville Florida 32217 Phone 800 961 7370 Fax 800 961 7379 Email spsales solerpalau usa com Soler Palau Canada 61 A Baywood Road Toronto ON M9V 3Y8 Phone 1 866 733 0233 Fax 1 866 358 5346 Ref 0288113004 ...

Отзывы: